Glowworm Lighting ULTRACOM CXI user manual

User manual for the device Glowworm Lighting ULTRACOM CXI

Device: Glowworm Lighting ULTRACOM CXI
Category: Boiler
Manufacturer: Glowworm Lighting
Size: 1.25 MB
Added : 8/23/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Glowworm Lighting ULTRACOM CXI. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Glowworm Lighting ULTRACOM CXI.

For your convenience

If looking through the Glowworm Lighting ULTRACOM CXI user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Glowworm Lighting ULTRACOM CXI on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Glowworm Lighting ULTRACOM CXI to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Glowworm Lighting ULTRACOM CXI User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Glowworm Lighting ULTRACOM CXI but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Glowworm Lighting ULTRACOM CXI. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Ultracom cxi
High Efficiency Condensing Boilers
Instructions for Use
To be left with the user
www.glow-worm.co.uk
www.glow-worm.co.uk 1

Summary of the content on the page No. 2

WARNING GAS LEAK OR FAULT Turn off the gas emergency control valve immediately. Eliminate all sources of ignition, i.e.smoking, blowlamps, hot air guns etc. Do not operate electrical lights or switches either on or off. Open all doors and windows, ventilate the area. METAL PARTS This boiler contains metal parts (components) and care should be taken when handling and cleaning, with particular regard to edges. SEALED COMPONENTS Under no circumstances must the user interfere with or adjust sealed p

Summary of the content on the page No. 3

Ultracom 24cxi G.C. No. 47-019-01 Ultracom 30cxi G.C. No. 47-019-02 Ultracom 38cxi G.C. No. 47-019-03 www.glow-worm.co.uk 3 13206

Summary of the content on the page No. 4

Contents Page Important Information 5 Boiler Design and Clearances 6 Boiler Safety Devices 7 Servicing, Maintenance and Spare Parts 8 User Control Panel 9 Lighting the Boiler 10 Adjusting Temperature 11 Setting the 24 hour Clock 12 Setting the Programmer 13 Advancing the Programmer 14 Fault Finding 15 These instructions are an integral part of the boiler and must, to comply with the current issue of the Gas Safety (Installation and Use) Regulations, be left with the user. Please read these instr

Summary of the content on the page No. 5

Important Information Gas Safety (Installation and Use) Regulations Testing and Certification In your own interests and that of safety, it is the Law that ALL This boiler is certificated to the current issue of EN 483 for gas appliances have been installed by a competent person performance and safety. in accordance with the current issue of these regulations. It is important that no alteration is made to the boiler unless approved, in writing, by Glow-worm. Gas Category Any alteration not approv

Summary of the content on the page No. 6

Boiler Design and Clearances Description CLEARANCES These boilers are designed for use as part of a sealed water (from casing panels) central heating system with fully pumped circulation. The pump, expansion vessel and associated safety devices are all 150 fitted within the boiler. The intelligent control system is designed for both simple operation and maximum control. Once the controls are set the boiler operates automatically. Pluming from flue terminal Like all condensing boilers it will pr

Summary of the content on the page No. 7

Boiler Safety Devices Boiler Shutdown Condensate Drain Blockage The boiler software is designed to recognise the potential for As a safety feature the boiler will stop working if the condensate an overheat lockout and will shutdown before this happens. drain becomes blocked. During freezing conditions this may To restart the boiler, press the reset button, see diagram 2. be due to the forming of ice in the condense drain external to the house. Release an ice blockage by the use of warm cloths

Summary of the content on the page No. 8

Servicing, Maintenance and Spare Parts General Note Frost Protection Servicing/maintenance should be carried out by a competent If the mains electricity and gas services are to be turned off for person in accordance with the rules in force in the countries any long periods during severe weather, it is recommended of destination. that the whole system, including the boiler, should be drained to avoid the risk of freezing. If this boiler is installed in a rented property in the UK there is a duty

Summary of the content on the page No. 9

User Control Panel General Description The User Control panel consists of three toggle buttons, a reset button and display, which will indicate with symbols the status of MODE the boiler, refer to diagram 2. PROG TOGGLE BUTTON DHW CH LCD RESET MODE and PROG TEMPERATURE DISPLAY BUTTON ADJUSTMENT SYMBOLS DISPLAYED ON THE LCD AND DESCRIPTIONS Will be displayed when domestic hot Central Heating Function Eco o water temperature is less than 50 C Ext Glow-worm control (Optional) Domestic Hot Wate

Summary of the content on the page No. 10

Lighting the Boiler Note: If the electrical supply has been interrupted for any Initial Lighting reason, you may need to set the clock and day before Remove the cover plate, refer to the fault finding section on continuing, refer to diagram 5. page 15 and diagram 8. 2. Select your required function, refer to diagram 9, press Check that all isolating valves and the gas service cock on "Mode" repeatedly to scroll through your options and select the appliance are open and that water flows from the

Summary of the content on the page No. 11

Press the "+ or -" once Press the "+ or -" once the current temperature the current temperature will be displayed "flashing". will be displayed "flashing". Adjusting Temperature Domestic Hot Water Central Heating Domestic Hot Water Domestic hot water has priority over central heating. The temperature is factory preset STEP 1 O STEP 1 to the minimum 40 C, but can be O adjusted to a maximum of 62 C as required, refer to diagram 4. Economy Setting O The "ECO" setting of 50 C is recommended and idea

Summary of the content on the page No. 12

Setting the 24 hour Clock To set the clock, refer to diagram 5. STEP 1 MODE PROG Press and hold "PROG" 5 secs. the "hours" symbol will flash. Press the "+" or the "-" STEP 2 to set the hour. STEP 3 MODE PROG Press "PROG" to confirm. The process will automatically scroll to minutes, then days (if the installer sets the 7 day function). Set as previously described for hours. Diagram 5 12 www.glow-worm.co.uk 13177

Summary of the content on the page No. 13

Setting the Programmer 24hr Timed Central Heating Factory preset timed intervals are:- ON 6.00 - OFF 8.00 ON 16.00 - OFF 23.00 To alter the times to suit your requirments, follow "Steps" 1 to 4 STEP 3 STEP 1 STEP 2 Press "PROG" button once to Press "+" to add a time segment Press + or - to move the flashing view the factory default or "-" to remove a time segment. cursor to the desired time. central heating running times. MODE PROG Flashing cursor. STEP 4 "Running Time" Press "PROG" to

Summary of the content on the page No. 14

Advancing the Programmer Advancing the timed central heating programmer ON /OFF times This function will only work when the appliance is in timed operating mode, "Clock symbol". Refer to diagram 2. The activated/deactivated segments will flash for 5 seconds. Press + and hold for 5 seconds your appliance will operate until the next OFF period, or you can cancel by pressing + for 5 seconds. Diagram 7 14 www.glow-worm.co.uk 13181

Summary of the content on the page No. 15

Fault Finding Appliance fails to light 2. Fully open tap "A", then gradually open tap "B" to fill the heating system to a pressure of 1.0bar. When completed The LCD will display a flashing 'F' and code number, press close the filling taps. the reset button on the control panel, see diagram 2. 3. IMPORTANT: To comply with the water regulations the If the display shows a flashing pressure of 0.4bar or less, flexible hose must be disconnected from the double check then you will need to pressurise

Summary of the content on the page No. 16

0020020822-02 11.06 Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions. Glow-worm, Nottingham Road, Belper, Derbyshire. DE56 1JT 16 www.glow-worm.co.uk


Alternative user manuals
# User manual Category Download
1 Sony HDV 1080I HVR-M15N/M15P User manual Boiler 67
2 Sony HDV 1080I HVR-M25N/M25P User manual Boiler 50
3 A.O. Smith 200 User manual Boiler 2
4 A.O. Smith 201 User manual Boiler 7
5 A.O. Smith 750 & 1000 User manual Boiler 6
6 A.O. Smith GB/GW-400 User manual Boiler 10
7 A.O. Smith DB/DW-720-1810 User manual Boiler 1
8 A.O. Smith DB-720 thru 1810 User manual Boiler 0
9 A.O. Smith GB/GW-650 User manual Boiler 3
10 A.O. Smith GB/GW-500 User manual Boiler 5
11 A.O. Smith GB/GW-200 User manual Boiler 2
12 A.O. Smith ACGSS02307 User manual Boiler 0
13 A.O. Smith 3400 User manual Boiler 0
14 A.O. Smith 1700 User manual Boiler 1
15 A.O. Smith 2000 User manual Boiler 3