UEi Digital Clamp-On Multimeter user manual

User manual for the device UEi Digital Clamp-On Multimeter

Device: UEi Digital Clamp-On Multimeter
Category: Portable Multimedia Player
Manufacturer: UEi
Size: 0.85 MB
Added : 2/26/2014
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for UEi Digital Clamp-On Multimeter. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with UEi Digital Clamp-On Multimeter.

For your convenience

If looking through the UEi Digital Clamp-On Multimeter user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual UEi Digital Clamp-On Multimeter on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual UEi Digital Clamp-On Multimeter to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
UEi Digital Clamp-On Multimeter User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual UEi Digital Clamp-On Multimeter but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to UEi Digital Clamp-On Multimeter. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTRUCTION MANUAL
DL250
1-800-547-5740 • Fax: (503) 643-6322
www.ueitest.com • email: info@ueitest.com

Summary of the content on the page No. 2

Introduction Safety Notes The DL250 Digital Clamp-on is the all-in-one test-tool that's designed Before using this meter, read all safety information carefully. In to make quick work of HVAC/R service and industrial maintenance. this manual the word "WARNING" is used to indicate conditions Whether you're measuring flame safeguard current, motor inrush or actions that may pose physical hazards to the user. The word current, run/start capacitors, recording time-stamped temperature "CAUTION"

Summary of the content on the page No. 3

4. Range and Time Stamp Push-button: Switches meter International Symbols from auto to manual ranging. Also initiates the time stamp function when used in conjunction with MA X / MIN / R e c o r d i n g . 5. Hold Push-button: Freezes the value displayed on the digital read-out. This function does not work while recording is in progress. Also turns on back light and work area light. 6. MAX/MIN Push-button: Use to cycle through recorded and present values, and the time stamp function. 7. Cl

Summary of the content on the page No. 4

The following describes the indicators displayed by the LCD. 29. OFL: This symbol appears when the input value exceeds the meters selected range or overall specification. 21 22 23 24 25 26 27 Operating Instructions 16 Auto Power Off 17 28 18 The instrument automatically shuts off after 30 minutes of inactivity. 19 The meter is considered active when there is a change of at least 10 20 digits during the period (i.e., the meter senses a change from 24.04 volts to 24.14 volts) 29 To disable this

Summary of the content on the page No. 5

When the “MIN/MAX” button is pressed a second time, the symbol B. Press the “TIME STAMP” button to return the display to the “MAX” appears at the top of the display, while the maximum recorded measured values. Press the “MIN/MAX” button; the “MIN” value is displayed. When the “MIN/MAX” button is pressed a third symbol appears at the top of the LCD and a value of “088.3” time, the “MIN” symbol appears at the top of the display, while the is displayed. Press the “TIME STAMP” button; the time sta

Summary of the content on the page No. 6

The maximum limit for this function is 400 amps AC. Too much Measuring Three-Phase AC Volts current will saturate the ferrous material in the clamp, and adversely affect accuracy. WARNING! This meter is primarily designed to measure residential, commercial WARNING! and light industrial AC voltage. When measuring 3-phase circuits, DO NOT attempt to take any unknown voltage or current measure m e n t s line-to-line, the value of the voltage is actually higher than the rated that may be in excess

Summary of the content on the page No. 7

The voltage or current applied during resistance measurements could Your meter is designed to apply enough voltage, in the forward biased damage some devices. Typically, the voltages applied in the resistance direction, to allow current flow. All diodes use up or “drop” a small ranges vary from 3 volts in the lowest range to 0.5 volts in the highest amount of the supplied voltage when they are forward biased. When range. Current will typically vary from 800 µA at the lowest range to 30 they are

Summary of the content on the page No. 8

Measuring Capacitance To measure AC or DC current flow (in amps): This meter measures capacitors, such as those used as motor-run-start 1. Ensure power is off to the circuit to be tested. capacitors, ranging in value from .001 to 10,000 microfarads (µf). 2. Insert the test leads into the meter (red to the multifunction port on the right, and black to the common port on the left). WARNING! Capacitors should be completely discharged prior to testing. 3. Set the rotary switch to the DC microamp

Summary of the content on the page No. 9

Cleaning and Decontamination Fuse Replacement Periodically clean your meter’s case using a damp cloth. DO NOT use The DC µA position is protected by a 400 mA fuse. If this fuse blows the abrasives, cleaning solvents or strong detergents, as they may damage meter will display all zeros (example, 00.00 mA) on the LCD when the the finish or affect the reliability of the structural components. DC µA function is selected, regardless of input. Battery Replacement Always use a fresh replacement battery

Summary of the content on the page No. 10

The specifications listed in the following table are based on an instru- Maximum voltage between any 600 V DC or AC RMS ment operating in an ambient temperature of between 65 and 90˚F, at a terminal and earth ground relative humidity of less than 80%, and within one year of calibration. Digital display 4000 Count - Updates 4 times per second The “accuracy” column indicates the percent of possible error based on Storage temperature -4˚ to 140˚F (-20˚ to 60˚) the reading displayed, plus an additi

Summary of the content on the page No. 11

DL250 Digital Clamp-On Multimeter Limited Warranty The DL250 is warranted to be free from defects in materials and workmanship for a period of three years from the date of purchase. If within the warra n ty period your instrument should become inoperative from such defects, the unit will be repaired or replaced at UE i ’ s option. This warra n ty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration, tampering, accident, misuse, abuse, ne


Alternative user manuals
# User manual Category Download
1 UEi DL250 User manual Portable Multimedia Player 41
2 Sony NWZ-F806 User manual Portable Multimedia Player 4
3 Sony Walkman NWZ-E573 User manual Portable Multimedia Player 5
4 Sony Walkman NWZ-E474 User manual Portable Multimedia Player 185
5 Sony NWZ-E475BLK User manual Portable Multimedia Player 15
6 Sony Walkman NWZ-E473K User manual Portable Multimedia Player 25
7 Sony SMP-NX20 User manual Portable Multimedia Player 6
8 Sony Walkman NWZ-E575 User manual Portable Multimedia Player 31
9 Sony Walkman NWZ-E475 User manual Portable Multimedia Player 11
10 Sony NWZ-F805 User manual Portable Multimedia Player 3
11 Sony Walkman NWZ-E464HK User manual Portable Multimedia Player 0
12 Actiontec electronic Actiontec MyWirelessTV MWTV200KIT01 User manual Portable Multimedia Player 32
13 Sony Walkman NWZ-E473 User manual Portable Multimedia Player 50
14 Air King 9166C User manual Portable Multimedia Player 0
15 Aluratek APMP101F User manual Portable Multimedia Player 0