Agilent Technologies PN 8510-16 user manual

User manual for the device Agilent Technologies PN 8510-16

Device: Agilent Technologies PN 8510-16
Category: Power Supply
Manufacturer: Agilent Technologies
Size: 0.39 MB
Added : 12/30/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Agilent Technologies PN 8510-16. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Agilent Technologies PN 8510-16.

For your convenience

If looking through the Agilent Technologies PN 8510-16 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Agilent Technologies PN 8510-16 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Agilent Technologies PN 8510-16 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Agilent Technologies PN 8510-16 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Agilent Technologies PN 8510-16 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Agilent Technologies PN 8510-16. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

UNCORRECTED POWER
CORRECTED POWER OUTPUT POWER
Agilent PN 8510-16
Controlling Test Port Output
Power Flatness
Product Note
Agilent 8510C Network Analyzer

Summary of the content on the page No. 2

Power flatness correction is useful for characteriz- Introduction ing active devices by allowing measurements of Designers and manufacturers of active devices absolute power, gain versus input power, and often need to control the power level at the test 1 swept-frequency gain compression. Swept-power port of their power-sensitive devices, but find dif- gain compression measurements are possible in ficulty in overcoming insertion losses. The insertion the power domain with the flatness correction

Summary of the content on the page No. 3

The Agilent 8511B frequency converter test System Configuration set may be used with the test port power flatness- The basic 8510C measurement system configura- correction feature. The range of the test port tion needed for test port flatness correction is power is determined by the available power of shown in Figure 1. A single channel power meter the 8360 source and the insertion loss of the com- such as the Agilent 437B, E4418A, or E4418B is ponents added to the measurement system. required

Summary of the content on the page No. 4

When the flatness correction is enabled in an Flatness-Correction Operation 8510C measurement system the analyzer’s Power The basic setup procedure to obtain flat test port Source 1 softkey controls the test port power level. output power is illustrated in Table 1. To simplify The source and test set used will determine the the execution of the procedure, the front panel available test port power range. hardkeys are enclosed in [brackets]. The softkeys are enclosed in {braces}. Table 2 provides

Summary of the content on the page No. 5

Table 1. Flatness-correction calibration procedure 8510C Keystrokes Description Set up the power meter (see Table 2) For proper operation, the E4418B must be set up before initiating the flatness-correction routine. See Table 2 for specific instructions. Verify the power meter's address on the 8510 system [LOCAL] When shipped from the factory, the address of the power meter is 13. If this conflicts with another instrument on the system bus, {POWERMETER} change the address of the conflicting in

Summary of the content on the page No. 6

Table 2. Agilent E4418B power meter setup E4418B Keystrokes Description Preset and zero the power meter [PRESET/LOCAL] Return the power meter to a known state. {CONFIRM} [ZERO/CAL] {ZERO} Set up the 437B emulation on the power meter [SYSTEM/INPUTS] The 437B command set must be activated in order to perform the power flatness calibration. Power meters that can be used in {REMOTE INTERFACE} place of the E4418B are the E4418A and 437B. The E4419B dual channel power meter does not have the 437B

Summary of the content on the page No. 7

Operational Considerations Calibration time The user may choose to speed up the calibration process by reducing the number of trace points on the analyzer. Table 5 provides some typical calibration times for flatness correction over the full frequency span of the source for different source/test set combinations. Calibration times may be slightly reduced by increasing the stepped measurement speed with the quick step feature on the Agilent 8510C. Table 5. Typical calibration times (in minutes) v

Summary of the content on the page No. 8

Verifying a flatness-correction calibration When to recalibrate To verify the flatness-correction calibration, the The flatness-correction calibration does not need power sensor should be reconnected to the test to be repeated unless: (1) the user wants to cali- port to measure the test port power at individual brate over a wider frequency range, (2) the meas- frequencies. Since the measurement system is urement path between the source and the test calibrated in 50W, inaccuracies will occur when

Summary of the content on the page No. 9

Using test port 1 calibrations on test port 2 Flatness corrections in fixture or wafer-probing In most cases, port 1 will be the input port of the environments DUT. When port 2 must be used as the input port Test port flatness correction may be applied to the device, the user may choose to use a port 1 with any other power function. Power slope may flatness-correction calibration on port 2 since the be used to compensate for the path loss in non- 1 port 1 and port 2 signal paths are symmetric

Summary of the content on the page No. 10

Practical Application Examples Absolute output power measurements with flatness correction One benefit of the flatness-correction capability is the ability to measure the absolute output power of active devices. Since the input power level to the DUT is kept constant, the magnitude offset feature of the Agilent 8510 can be used to display absolute output power across the entire frequency span of the device. Table 6 shows the procedure for absolute output power versus frequency measure- ments wi

Summary of the content on the page No. 11

Amplifier measurement example output power, and gain compression measurements Step-by-step instructions for setting up and apply- procedures are covered. For more information on ing flatness corrections for the measurement of measuring amplifiers, refer to Agilent product note an amplifier are shown in Table 7. Gain, absolute 8510-18, literature number 5963-2352E. Table 7. Absolute output power and 1 dB compression measurements of an amplifier 8510C Keystrokes Description Perform the flatness-co

Summary of the content on the page No. 12

Agilent Technologies’ Test and Measurement By internet, phone, or fax, get assistance with all your Support, Services, and Assistance test and measurement needs. Agilent Technologies aims to maximize the value you receive, Online Assistance while minimizing your risk and problems. We strive to ensure www.agilent.com/find/assist that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support Phone or Fax resources and services can help you


Alternative user manuals
# User manual Category Download
1 Agilent Technologies 6032A User manual Power Supply 16
2 Agilent Technologies 6012B User manual Power Supply 4
3 Agilent Technologies 6038A 6010A User manual Power Supply 3
4 Agilent Technologies 6023A, 6028A User manual Power Supply 5
5 Agilent Technologies 6035A User manual Power Supply 8
6 Agilent Technologies 6011A User manual Power Supply 1
7 Agilent Technologies 6023A User manual Power Supply 0
8 Agilent Technologies 6611C User manual Power Supply 19
9 Agilent Technologies 6031A User manual Power Supply 1
10 Agilent Technologies 6625A User manual Power Supply 0
11 Agilent Technologies 6632B User manual Power Supply 22
12 Agilent Technologies 6634B User manual Power Supply 5
13 Agilent Technologies 6629A User manual Power Supply 0
14 Agilent Technologies 6614C User manual Power Supply 7
15 Agilent Technologies 6628A User manual Power Supply 1
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2