APC NETBOTZ NBRK0200 user manual

User manual for the device APC NETBOTZ NBRK0200

Device: APC NETBOTZ NBRK0200
Category: Power Supply
Manufacturer: APC
Size: 0.57 MB
Added : 7/6/2013
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC NETBOTZ NBRK0200. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC NETBOTZ NBRK0200.

For your convenience

If looking through the APC NETBOTZ NBRK0200 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC NETBOTZ NBRK0200 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC NETBOTZ NBRK0200 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC NETBOTZ NBRK0200 User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC NETBOTZ NBRK0200 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC NETBOTZ NBRK0200. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Installation and
Quick Configuration
Manual
®
NetBotz
Rack Monitor 200
NBRK0200

Summary of the content on the page No. 2

This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar. Este manual está disponible en español en el CD-ROM adjunto. Ce manuel est disponible en français sur le CD-ROM ci-inclus. Questo manuale è disponibile in italiano nel CD-ROM allegato. 本マニュアルの日本語版は同梱の CD-ROMからご覧になれます。 O manual em Português está disponível no CD-ROM em anexo. Да нное ру к о в о дс тво на русско м яз ы к е им ее т с я на п р илагаем ом ком пак т- дис к е. 您

Summary of the content on the page No. 3

Contents Introduction ..................................................................... 1 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Document Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Additional Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Receiving Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Inventory . .

Summary of the content on the page No. 4

Important Information about the Default Gateway . . . . . . . . . . . . . 16 How to Update the BOOTPTAB File . . . . . . . . . . . . . . . . . . . . . . . . . 16 How to Use the APC Device IP Configuration Wizard. . . . . . . . . . . 17 How to Use ARP, Ping, and Telnet . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Control Console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 How to access the control console . . . . . . . . . . . . . . . . . . . . .

Summary of the content on the page No. 5

Introduction Product Description ® The American Power Conversion (APC ) NetBotz Rack Monitor 200 is a central hardware appliance for an APC environmental monitoring and control system. The rack-mountable Rack Monitor 200 includes six universal sensor ports for connecting temperature and humidity sensors, door switch sensors, and third-party dry contact sensors. Using other ports on the Rack Monitor 200, you can connect up to eight temperature and humidity sensors with digital display. To exp

Summary of the content on the page No. 6

Receiving Inspection Inspect the package and its contents for shipping damage and ensure that the parts included in the shipment match all of the parts listed in the inventory table. Immediately report any shipping damage to the shipping agent. Report missing contents, damage, or other problems to APC or your APC reseller. The shipping materials are recyclable. Please save them for later use, or dispose of them appropriately. Inventory Quantity Item 1 NetBotz Rack Monitor 200 (NBRK0200) 1 Har

Summary of the content on the page No. 7

Quantity Item 1 Hardware kit for Temperature/Humidity Sensor Quantity Item 5 203-mm (8-in) nylon tie wrap 2 19 x 19-mm (3/4 x 3/4-in) adhesive-backed cable tie mount 1 Temperature/humidity sensor mount (25 x 25-mm [1 x 1-in] adhesive-backed cable tie mount) 1 #6 - #10 wall anchor 1 #8 x 3/4-in sheet metal screw Additional Options The following options are available for the Rack Monitor 200. For more information, contact your APC representative or the distributor from whom you purchased your AP

Summary of the content on the page No. 8

Installation Physical Description Rear ® Toolless mounting pegs allow for installation in APC NetShelter VX and SX racks and enclosures without using any U-spaces. (For more details, see “Toolless peg-mount installation” on page 6.) Front Item Description AC Line Inlet Provides for the input power connection; see “Specifications” on page 23 for voltage  information. Switched Outlet Provides power to a device at a total maximum amperage of 10 A. Activates a connected  device when configured

Summary of the content on the page No. 9

Item Description A-Link ports Used to cascade up to twelve NetBotz Rack Sensor Pod 150s (NBPD0150) and a combined  total of eight Temperature Sensors with Digital Display (AP9520T) and Temperature/ Humidity Sensors with Digital Display (AP9520TH). Provides communications and power using standard CAT-5 cabling with straight-through wiring. Note: If you cascade ten or more devices, you must connect a supplemental power supply (Power Supply 100-120 Vac/24 Vdc—AP9505i) to a NetBotz Rack Sensor

Summary of the content on the page No. 10

How to Install the Rack Monitor 200 Note: Install the Rack Monitor 200 in an environment compatible with the environmental specifications on page 23. Note: When you install the Rack Monitor 200 in the rack, do not create a hazardous condition due to uneven mechanical loading. For example, do not use the Rack Monitor 200 as a shelf. You can install the Rack Monitor 200 in the front or the rear of the rack using the rack-mount option, ® which requires 1 U of rack space. If using an APC NetShel

Summary of the content on the page No. 11

Rack-mount installation 1. Choose a location for the Rack Monitor 200 in the front or rear of the rack. The Rack Monitor 200 occupies one U-space. A notched hole or a number on the vertical rail of the rack denotes the middle of a U-space. Caution: To avoid equipment damage, use only the hardware provided when installing the brackets. 2. Install the brackets ( and ), including   the power cord retainer bracket, on the end nearest the AC Line Inlet. 8-32 x 1/4-in Phillips-head screws  Bra

Summary of the content on the page No. 12

Power cord and network cable connections Perform the steps below to complete the installation of the Rack Monitor 200. Caution: Before you energize the Rack Monitor 200, review the electrical specifications on page 23 to avoid overloading the circuit providing power. Caution: Make sure you properly ground the Rack Monitor 200 by plugging it directly into a wall outlet or by verifying the ground path if you connect the appliance to a power strip. 1. Connect the appropriate power cord to the AC

Summary of the content on the page No. 13

How to Install the Temperature/Humidity Sensor 1. Choose a location and install the temperature/humidity sensor. Avoid locations in direct sunlight or other locations that may affect the sensor reading, such as near windows, room entrances, air ducts, or other heat sources. Note: When securing the sensor, tighten the tie wrap over the recessed channel of the sensor casing. Vertical rail installation. Firmly install the sensor mount (25 x 25-mm [1 x 1-in] cable tie mount) at the location yo

Summary of the content on the page No. 14

How to Connect Sensors to Universal Sensor Ports This procedure applies to the following sensors, which are supported by the Rack Monitor 200 and connect to the universal sensor ports: • Temperature Sensor (AP9335T) • Temperature/Humidity Sensor (AP9335TH) • NetBotz 3.65-m (12-ft) Door Switch Sensor for APC Racks (NBES0303) • NetBotz 15.24-m (50-ft) Door Switch Sensor for Rooms or Third Party Racks (NBES0302) • NetBotz Dry Contact Cable (NBES0304) For sensors that connect to A-Link ports (Tempe

Summary of the content on the page No. 15

How to Connect an Alarm Beacon and Other Optional Devices 1. To install an alarm beacon: – Mount the alarm beacon in a visible position either on the roof of the rack or inside the rack. – Route the alarm beacon cable to the Rack Monitor 200. The alarm beacon cable may be extended to a maximum of 100 m (300 ft), using RJ-45 couplings and standard CAT-5 cables. – Connect the cable to the Beacon port. 2. Connect one device to the Voltage Output. Caution: The Relay Output is rated for Class 2

Summary of the content on the page No. 16

How to Cascade Devices to A-Link Ports You can cascade to A-Link ports up to twelve NetBotz Rack Sensor Pod 150s (NBPD0150) and up to a combined total of eight Temperature Sensors with Digital Display (AP9520T) and Temperature/ Humidity Sensors with Digital Display (AP9520TH). You cannot cascade Rack Monitor 200s. Use one Rack Monitor 200 per system. A-Link is an APC proprietary CAN (Controller Area Network) bus. Devices compatible with A-Link are not Ethernet devices and cannot coexist on an

Summary of the content on the page No. 17

How to Wire to the Modbus Interface To connect to your building management system, use the Modbus RS-485 interface. The Modbus interface supports 2-wire RS-485, plus ground. In addition, Modbus requires both termination and polarization resistors at the bus master. Each end of the bus requires a 150-ohm resistor (provided), and the bus also requires a 400–650-ohm resistor (provided) from D1 to +5 Vdc and from D0 to GND. Modbus can be configured to communicate at either 9600 or 19200 bps. The

Summary of the content on the page No. 18

Quick Configuration Note: Disregard the procedures in this section if you have APC InfraStruXure Central or InfraStruXure Manager as part of your system. See the documentation for your InfraStruXure device for more information. Consult with your network administrator to determine the type of network server to which the Rack Monitor 200 is connected. Then follow the table below to complete the configuration process, which results in the assignment of network communication settings and enables

Summary of the content on the page No. 19

DHCP Server The DHCP server must be set up with an encapsulated APC cookie in the Vendor Specific Information option (DHCP option 43); otherwise, DHCP offers will be ignored by the Rack Monitor 200. If you do not want to use option 43, disable the cookie requirement (see “How to disable the cookie requirement” on this page). For complete details on Rack Monitor 200 communication with a DHCP server, see “TCP/IP and Communication Settings” in the NetBotz Rack Monitor 200 User’s Guide. For det

Summary of the content on the page No. 20

Important Information about the Default Gateway Observe the following when required to enter a default gateway for the Rack Monitor 200. (Refer to page 14.) Note: If a default gateway is unavailable, use the IP address of a computer that is located on the same subnet as the Rack Monitor 200 and that is usually running. The Rack Monitor 200 uses the default gateway to test the network when traffic is very light. Caution: Do not use the loopback address (127.0.0.1) as the default gateway addres


Alternative user manuals
# User manual Category Download
1 APC 208 Vac User manual Power Supply 8
2 APC 1400XLT User manual Power Supply 23
3 APC 15A User manual Power Supply 0
4 APC 120V User manual Power Supply 5
5 APC 2200XLT User manual Power Supply 24
6 APC 2000XL User manual Power Supply 15
7 APC 1000VA User manual Power Supply 24
8 APC 1500 VA User manual Power Supply 46
9 APC 300 User manual Power Supply 404
10 APC 5000VA User manual Power Supply 60
11 APC 500 User manual Power Supply 26
12 APC 3000VA User manual Power Supply 12
13 APC 3000T User manual Power Supply 1
14 APC 600 User manual Power Supply 64
15 APC 2AP9604S User manual Power Supply 1
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2