Fuji Bikes FRENIC 5000G11S/P11S user manual

User manual for the device Fuji Bikes FRENIC 5000G11S/P11S

Device: Fuji Bikes FRENIC 5000G11S/P11S
Category: Power Supply
Manufacturer: Fuji Bikes
Size: 3.01 MB
Added : 4/14/2014
Number of pages: 132
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Fuji Bikes FRENIC 5000G11S/P11S. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Fuji Bikes FRENIC 5000G11S/P11S.

For your convenience

If looking through the Fuji Bikes FRENIC 5000G11S/P11S user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Fuji Bikes FRENIC 5000G11S/P11S on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Fuji Bikes FRENIC 5000G11S/P11S to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Fuji Bikes FRENIC 5000G11S/P11S User manual - Online PDF
Advertisement
« Page 1 of 132 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Fuji Bikes FRENIC 5000G11S/P11S but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Fuji Bikes FRENIC 5000G11S/P11S. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual



FRENIC 5000G11S/P11S







High-Performance, Low-Noise Inverter


General-Purpose Industrial Machines Fans and Pumps
230V Series 230V Series
0.25HP/FRNF25G11S-2UX 7.5HP/FRN007P11S-2UX
to 125HP/FRN125G11S-2UX to 150HP/FRN150P11S-2UX
460V Series 460V Series
0.50HP/FRNF50G11S-4UX 7.5HP/FRN007P11S-4UX
to 600HP/FRN600G11S-4UX to 800HP/FRN800P11S-4UX




CAUTION


Read all operating instructions before
installing, connecting (wiring),
operatin

Summary of the content on the page No. 2

Preface Thank you four purchasing our FRENIC5000G11S or FRENIC5000P11S series inverter. This product is used to drive a 3-phase electric motor at variable speed. As incorrect use of this product may result in personal injury and/or property damage, read all operating instructions before using. As this manual does not cover the use of option cards, etc., refer to relevant manuals for option operations. Safety Instructions Read this manual carefully before installing, connecting (wiring)

Summary of the content on the page No. 3

Instructions on wiring WARNING • Connect the inverter to power via a line-protection molded-case circuit breaker or Fuse, as fire may result. • Always connect a ground wire, as electric shock or fire may result. • A licensed specialist must perform the wiring works, as electric shock may result. • Turn off the power before starting the wiring work, as electric shock may result. • Wire the inverter after installation is complete, as electric shock or injury may occur. CAUTION • Con

Summary of the content on the page No. 4

Instructions on maintenance, inspection, and replacement WARNING • Wait a minimum of five minutes (30HP or less) or ten minutes (40HP or more) after power has been tumed off (open) before starting inspection. (Also confirm that the charge lamp is off and that DC voltage between terminals P (+) and N (-) do not exceed 25V.) Electrical shock may result. • Only authorized personnel should perform maintenance, inspection, and replacement operations.(Take off metal jewelry such as watches an

Summary of the content on the page No. 5

Conformity to Low Voltage Directive in Europe CAUTION Table 1-1 Applicable equipment and wire size for main circuit in Europe Fuse/MCCB 2 Tightening torque [N*m] Recommended wire size [mm ] current rating [A] L1/R, L2/S, L3/T Inverter type With Without ( G) G DCR DCR With Without DCR DCR 1/4 FRNF25G11S-2UX 5 5 1/2 FRNF50G11S-2UX 5 5 1.2 - - 2.5 1 FRN001G11S-2UX 5 10 2.5 (2.5) 2.5 2.5 (2.5) 2 FRN002G11S-2UX 10 15 3 FRN003G11S-2UX 10 15 1.8 5 FRN005G11S-2UX 20 30 4(4) 7.5 F

Summary of the content on the page No. 6

Conformity to Low Voltage Directive in Europe CAUTION Table 1-2 Applicable equipment and wire size for main circuit in Europe Fuse/MCCB 2 Tightening torque [N*m] Recommended wire size [mm ] current rating [A] L1/R, L2/S, L3/T Inverter type With Without ( G) G DCR DCR With Without DCR DCR 1/2 FRNF50G11S-4UX 5 5 1.2 - - 1 FRN001G11S-4UX 5 5 2 FRN002G11S-4UX 5 10 2.5 3 FRN003G11S-4UX 10 15 1.8 (2.5) 2.5 5 FRN005G11S-4UX 10 15 2.5 2.5 (2.5) 7.5 FRN007P11S-4UX 15 20 7.5 FRN0

Summary of the content on the page No. 7

Compliance with UL/cUL standards [Applicable to products with UL/cUL mark] CAUTION Tightening torque and wire range 2 . Inverter type Wire range [AWG] (mm ) Required torque [lb-inch](N m) Auxiliary Auxiliary Voltage Main L1/R,L2/S,L3/T G11S/P11S control- Control control- Control terminal U,V,W power power FRNF25G11S-2UX FRNF50G11S-2UX 10.6(1.2) ― ― 16 (1.3) FRN001G11S-2UX FRN002G11S-2UX 15.9(1.8) FRN003G11S-2UX 14 (2.1) FRN005G11S-2UX 10 (5.3) FRN007G11S-2UX 8 (8.4) FRN007,010P1

Summary of the content on the page No. 8

Compliance with UL/cUL standards [Applicable to products with UL/cUL mark] CAUTION • [CAUTION] Hazard of electrical shock. Disconnect incoming power before working on this control. • [CAUTION] Dangerous voltage exists until charge lights is off. • [WARNING] • More than one live parts inside the inverter. • Type1 “INDOOR USE ONLY” The inverter is approved as a part used inside a panel. Install it inside a panel. • Suitable for use on a circuit capable of delivering not more than 100,0

Summary of the content on the page No. 9

Contents ・・・・・・・・・・・・・・・ ・・・・・・・・・・・・・・・・・・・・・・・・ 1. Before Using This Product 1-1 5. Function Select 5-1 1-1 Receiving Inspections ・・・・・・・・・・・・・・・・1-1 5-1 Function select list ・・・・・・・・・・・・・・・・・・・ 5-1 ・・・・・・・・・・・・・・・・・・・・・・・・ 1-2 Appearance 1-1 5-2 Function Explanation ・・・・・・・・・・・・・・・・ 5-7 1-3 Handling the Product ・・・・・・・・・・・・・・・・・1-2 1-4 Carrying ・・・・・・・・・・・・・・・・・・・・・・・・・・・・1-3 6. Protective Operation ・・・・・・・・・・・・・・・・・・・・ 6-1 1-5 Storage ・・・・・・・・・・・・・・・・・・・・・・・・・・・・1-3 6-1 List of Prot

Summary of the content on the page No. 10

1. Before Using This Product 1-1 Receiving Inspections Unpack and check the product as explained below. If you have any questions about the product, contact the nearest Fuji sales office or your local distributor where you purchased the unit. ① Check the ratings nameplate to confirm that the delivered product is the ordered one. Ratings nameplate TYPE : Inverter type FRN 030 G11S-4 UX Power supply voltage system :2→ 230V grade、4→460V grade Se

Summary of the content on the page No. 11

1-3 Handling the Product (1) Removing the surface cover For the inverter of 30HP or less, loosen the mounting screws of the surface cover, then remove the cover by pulling the top (see Figure 1.3.1). Fig. 1-3-1 Removing the surface cover (for inverter of 30HP or less) For the inverter of 40HP or more, remove the six mounting screws of the surface cover, then remove the surface cover. Fig. 1-3-2 Removing the surface cover (for inverter of 40HP or more) (2) Removing the keypad panel

Summary of the content on the page No. 12

1-4 Carrying Carry the product by the main unit. Do not carry the product while holding the cover or parts other than the main unit. Use a crane or hoist to carry a product equipped with hanging holes. 1-5 Storage Temporary storage Temporary storage of this product must meet those conditions listed in Table 1-5-1. Table 1-5-1 Storage environment Item Specifications Ambient -10℃(14ºF) to +50℃(122ºF) temperature Storage Condensation or freezing must not occur as a result of -25℃(-13ºF)

Summary of the content on the page No. 13

2. Installation and Connection 2-1 Operating Environment Install this product in a location that meets those conditions listed in Table 2-1-1 Table 2-1-1 Operating environment Table 2-1-2 Output current reduction rate Item Specifications based on altitude Location Indoor Altitude Output current reduction rate -10℃(14ºF) to +50℃(122ºF)(For products of Ambient 30HP or less, the ventilating covers must be 3300ft (1000m) or lower 1.00 temperature 3300-4950ft (1000 to 1500m) 0.97 removed

Summary of the content on the page No. 14

An inverter of 40HP or more can be converted to an external cooling type simply by moving upper and lower mounting brackets as shown in Fig. 2-2-3. Remove the M6 bracket screws, move the brackets, then secure the brackets using the M5 case mounting screws. (The bracket screws are no longer required after changing the bracket mounting position.) Quantity of mounting screw Voltage Case mounting Inverter type Bracket screws series screws FRN040G11S-2UX to FRN100G11S-2UX 5 5 FRN040P11S

Summary of the content on the page No. 15

2-3 Connection Remove the surface cover before connecting the terminal blocks as follows. 2-3-1 Basic connection ①Always connect power to the L1/R, L2/S, and L3/T main circuit power terminals of the inverter. Connecting power to another terminal will damage the inverter. Check that the power voltage is within the maximum allowable voltage marked on the nameplate, etc. ②Always ground the ground terminal to prevent disasters such as fire or electric shock and to minimize noise. ③Use

Summary of the content on the page No. 16

Basic Connection Diagram (Sink Logic) G11S:15HP and above G11S:Up to 10HP P11S:20HP and above P11S:Up to 15HP DB) (CM) (THR) Ground-fault circuit interrupter (GFCI) RS-485 Fig.2-3-1 Note: The control circuit common terminals [11], (CM) and are isolated (*1) Use a drive with rated voltage matching the power supply voltage. (*2) Use as required. (*3) Use this peripheral device when necessary. (*4) Remove the jumper wire (*4) between P1 and P(+) before connecting a DC R

Summary of the content on the page No. 17

Basic Connection Diagram to PLC (Sink Logic) G11S:15HP and above G11S:Up to 10HP P11S:20HP and above P11S:Up to 15HP Ground-fault circuit interrupter (GFCI) RS-485 Fig.2-3-2 2-5

Summary of the content on the page No. 18

Basic Connection Diagram (Source Logic, Typically used in Europe) G11S:15HP and above G11S:Up to 10HP P11S:20HP and above P11S:Up to 15HP Ground-fault circuit interrupter (GFCI) RS-485 Fig.2-3-3 Note: The control circuit common terminals [11], (CM) and are isolated (*1) Use a drive with rated voltage matching the power supply voltage. (*2) Use as required. (*3) Use this peripheral device when necessary. (*4) Remove the jumper wire (*4) between P1 and P(+) before connectin

Summary of the content on the page No. 19

Basic Connection Diagram to PLC (Source logic, Typically used in Europe) G11S:Up to 10HP G11S:15HP and above P11S:Up to 15HP P11S:20HP and above (THR) (P24) Ground-fault circuit interrupter (GFCI) RS-485 Fig.2-3-4 2-7

Summary of the content on the page No. 20

2-3-2 Connecting the main circuit and ground terminals Table 2-3-1 Functions of main circuit terminals and ground terminals Symbol Terminal name Description L1/R, L2/S, L3/T Main circuit power terminal Connects a 3-phase power supply. U, V, W Inverter output terminal Connects a 3-phase motor. Connects a backup AC power supply to the Auxiliary control-power R0, T0 control circuit. (Not supported for inverter of 1HP input terminal or less) DC reactor connecting Connects the optional p


Alternative user manuals
# User manual Category Download
1 Sony AC U50A User manual Power Supply 5
2 Sony AC LS1 User manual Power Supply 2
3 Sony NP-FM30 User manual Power Supply 35
4 Sony NP FX101 User manual Power Supply 1
5 Sony NH-AAA-DA User manual Power Supply 2
6 3Com 3645A User manual Power Supply 0
7 3Com 3CNJPSE24 User manual Power Supply 2
8 3Com COREBUILDER 5000 User manual Power Supply 0
9 3Com 3646A User manual Power Supply 0
10 3Com External PoE Power System PSE2500-A3 User manual Power Supply 1
11 Sony AC E45HG User manual Power Supply 10
12 3Com Powerware Uninterruptible Power System Prestige Series User manual Power Supply 7
13 AB Soft ATX 12V User manual Power Supply 0
14 AC International Lenze SV01B User manual Power Supply 8
15 AC International Lenze V0100 User manual Power Supply 0