Device: National Instruments FP-PS-4
Category: Power Supply
Manufacturer: National Instruments
Size: 0.52 MB
Added : 12/14/2013
Number of pages: 11
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments FP-PS-4. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments FP-PS-4.

For your convenience

If looking through the National Instruments FP-PS-4 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments FP-PS-4 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments FP-PS-4 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments FP-PS-4 User manual - Online PDF
Advertisement
« Page 1 of 11 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments FP-PS-4 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments FP-PS-4. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OPERATING INSTRUCTIONS
FP-PS-4
FieldPoint Power Supply
These operating instructions describe the installation, features, and
characteristics of the FP-PS-4.
Features
The FP-PS-4 is a FieldPoint power supply module with the
following features:
 24 VDC output
 Convenient DIN rail mounting or optional panel mounting
 Universal AC power input: 90 to 264 VAC, 47 to 63 Hz
 Modular FieldPoint form factor for easy integration with other
FieldPoint modules
 15 W output for 0 to 50 °C operation
Insta

Summary of the content on the page No. 2

NATIONAL FP-PS-4 INSTRUMENTS 24VDC Power Supply INPUT 100-240V 47-63Hz 0.6A Max ! OUTPUT 24V @ 0.6A Max 1. Use a flat-bladed screwdriver to unlock the DIN rail clip, as showninFigure1. 1 2 1 Rail clip locked 2 Rail clip unlocked Figure 1. Unlocking the Rail Clip 2. Attach the lip on the rear of the FP-PS-4 onto the top of a 35 mm DIN rail and press it down onto the DIN rail, as shown in Figure 2. Figure 2. Attaching the Module to a DIN Rail FP-PS-4 Operating Instructions 2 ni.com

Summary of the content on the page No. 3

3. Slide the FP-PS-4 to the desired position along the DIN rail. For maximum cooling, leave a 25 mm (1.0 in.) space between the FP-PS-4 and other devices on your DIN rail. After it is in position, lock it to the DIN rail by pushing the rail clip to the locked position, as shown in Figure 3. Figure 3. Positioning and Locking Your Module © National Instruments Corp. 3 FP-PS-4 Operating Instructions

Summary of the content on the page No. 4

Mounting Your FP-PS-4 on a Panel Follow these steps to install the optional FieldPoint network panel mount accessory and mount the FP-PS-4 power supply module to a panel. You can order the panel mount accessory, part number 777609-01, from National Instruments. 1. Use a flat-bladed screwdriver to unlock the rail clip, as shown in Figure 1. 2. Attach the panel mount accessory to the module, as shown in Figure 4. Figure 4. Installing the Panel Mount Accessory 3. Lock the panel mount accessory into

Summary of the content on the page No. 5

4. Mount the FP-PS-4 to your panel with the panel mount accessory, as shown in Figure 5. The installation guide that comes with the panel mount accessory includes a template that you can use to drill pilot holes for mounting FieldPoint modules. For maximum cooling, leave a 25 mm (1.0 in.) space between the FP-PS-4 and other devices. Figure 5. Connecting Your FP-PS-4 to the Panel Connecting Power to Your FieldPoint System Caution Before you connect the FP-PS-4 to your FieldPoint system, make sure

Summary of the content on the page No. 6

needs. Select one or a combination of the methods to power the signals of each of your I/O modules:  The signals of the I/O module are powered by an FP-PS-4 that is connected to only that I/O module.  The signals of the I/O module share an FP-PS-4 with a neighboring I/O module or network module. This is called cascading power. Caution Cascading power from neighboring bases or network modules defeats isolation between cascaded modules. Figure 6 shows a combination of the two ways to power the F

Summary of the content on the page No. 7

Ensure that all the wiring is installed according to local codes and regulations by qualified electrical personnel. Follow these steps to connect the FP-PS-4 to your FieldPoint system. 1. Use a 16 to 26 AWG stranded wire to connect the FP-PS-4 to your FieldPoint network module or I/O module. Connect the positive wire to the V terminal and the negative wire to the C terminal of the FP-PS-4. 2. Connect the other ends of the wires to the V and C terminals of the FieldPoint network module or I/O mod

Summary of the content on the page No. 8

6. Connect the green or green/yellow conductor into the ground terminal. Caution When you install the conductors, make sure that the entire conductor is in the screw terminal and that there are no loose strands outside of the terminal. Only install one wire in each terminal. Specifications The following specifications are typical for a range of 0 to 60 °C, unless otherwise noted. Installation Terminal wiring ................................16-26 AWG copper conductor wire with 7 mm (0.275 in.) st

Summary of the content on the page No. 9

Overload protection ..........................Protected against short circuits and output overload Physical Indicator............................................Green DC POWER LED Weight...............................................300 g (10.5 oz) Environmental FieldPoint modules are intended for indoor use only. Operating temperature 15 W operation...........................0 to 50 °C 10 W operation...........................50 to 60 °C Storage temperature.......................... –40 to +85

Summary of the content on the page No. 10

regulatory compliance information. To obtain the DoC for this product, click Declaration of Conformity at ni.com/hardref.nsf/. Mechanical Dimensions Figure 9 shows the mechanical dimensions of the FP-PS-4. Dimensions are given in millimeters [inches]. 107.19 [4.22] 109.5 [4.31] 91.44 [3.60] Figure 9. Mechanical Dimensions FP-PS-4 Operating Instructions 10 ni.com

Summary of the content on the page No. 11

Where to Go for Support For more information about setting up your FieldPoint system, refer to these National Instruments documents:  Your FieldPoint network module user manual  Your other FieldPoint I/O module operating instructions  Your FieldPoint terminal base operating instructions Go toni.com/support for the most current manuals, examples, and troubleshooting information. For telephone support in the United States, create your service request atni.com/ask and follow the calling instruct


Alternative user manuals
# User manual Category Download
1 National Instruments NI PXI-1006 User manual Power Supply 2
2 National Instruments NI PXI-1042 User manual Power Supply 11
3 National Instruments NI PXI-1042 Series User manual Power Supply 19
4 National Instruments PXI-1045 User manual Power Supply 6
5 Sony AC U50A User manual Power Supply 5
6 Sony AC LS1 User manual Power Supply 2
7 Sony NP-FM30 User manual Power Supply 35
8 Sony NP FX101 User manual Power Supply 1
9 Sony NH-AAA-DA User manual Power Supply 2
10 3Com 3645A User manual Power Supply 0
11 3Com 3CNJPSE24 User manual Power Supply 2
12 3Com COREBUILDER 5000 User manual Power Supply 0
13 3Com 3646A User manual Power Supply 0
14 3Com External PoE Power System PSE2500-A3 User manual Power Supply 1
15 Sony AC E45HG User manual Power Supply 10