Powerware Corporation15 KVA user manual

User manual for the device Powerware Corporation15 KVA

Device: Powerware Corporation15 KVA
Category: Power Supply
Manufacturer: Powerware
Size: 7.3 MB
Added : 11/18/2013
Number of pages: 98
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Powerware Corporation15 KVA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Powerware Corporation15 KVA.

For your convenience

If looking through the Powerware Corporation15 KVA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Powerware Corporation15 KVA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Powerware Corporation15 KVA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Powerware Corporation15 KVA User manual - Online PDF
Advertisement
« Page 1 of 98 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Powerware Corporation15 KVA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Powerware Corporation15 KVA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Powerware 9355 UPS
10/15 kVA
User’s Guide

Summary of the content on the page No. 2

ClassAEMCStatements FCCPart15 NOTE This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to rad

Summary of the content on the page No. 3

RequestingaDeclarationofConformity Units that are labeled with a CE mark comply with the following harmonized standards and EU directives: S Harmonized Standards: IEC 62040-1-1 and IEC 62040-2; IEC 60950 Third Edition S EU Directives: 73/23/EEC, Council Directive on equipment designed for use within certain voltage limits 93/68/EEC, Amending Directive 73/23/EEC 89/336/EEC, Council Directive relating to electromagnetic compatibility 92/31/EEC, Amending Directive 89/336/EEC relating to EMC The EC

Summary of the content on the page No. 4

SpecialSymbols The following are examples of symbols used on the UPS to alert you to important information: RISKOFELECTRICSHOCK-Indicatesthatariskofelectricshockispresentandtheassociated warningshouldbeobserved. CAUTION: REFERTOOPERATOR’SMANUAL-Refertoyouroperator’smanualforadditional information,suchasimportantoperatingandmaintenanceinstructions. ThissymbolindicatesthatyoushouldnotdiscardtheUPSortheUPSbatteriesinthetrash.This productcontainssealed,lead-acidbatteriesandmustbedisposedofproperly.F

Summary of the content on the page No. 5

Table of Contents 1 Introduction ......................................................... 1 2 SafetyWarnings ..................................................... 5 3 UPSSetup .......................................................... 9 Inspecting the Equipment.................................................. 9 Floor Loading ............................................................ 10 Clearances............................................................... 10 Unloading the Cabinet(s) .....

Summary of the content on the page No. 6

TABLE OF CONTENTS 9 Operation ........................................................... 65 Control Panel Functions ................................................... 65 Changing the Language ................................................. 66 Display Functions ...................................................... 66 User Settings .......................................................... 68 Initial Startup ............................................................. 70 UPS Startup.........

Summary of the content on the page No. 7

Chapter 1 Introduction ® The Powerware 9355 uninterruptible power supply (UPS) is a true online, double-conversion three-phase system that can be used to prevent loss of valuable electronic information and minimize equipment downtime. It is ideal for protecting essential information technology and electrical engineering infrastructure in corporate, telecom, health care, banking, and industrial applications. The Powerware 9355 UPS continually monitors incoming electrical power and removes the sur

Summary of the content on the page No. 8

INTRODUCTION Providing outstanding performance and reliability, the Powerware 9355 UPS’s unique benefits including the following: S Online UPS design with pure sine wave output. The UPS filters and regulates incoming AC power and provides consistent power to your equipment without draining the battery. S More wattage in less space with a 0.9 power factor – protecting more equipment and leaving more room for expansion. S A UPS maintenance bypass switch provides a Make-Before-Break (MBB) wrap-arou

Summary of the content on the page No. 9

INTRODUCTION The following options for the Powerware 9355 are available: S RemoteMonitorPanel(RMP) The optional RMP provides monitoring of the operational status and alarm condition of the UPS from virtually any location within the facility. You can install multiple RMPs at remote locations to increase your monitoring capabilities. S PowerDistributionModule(PDM) The optional PDM comes equipped with several different types of output receptacles. S ParallelTieCabinet An optional parallel system wi

Summary of the content on the page No. 10

INTRODUCTION ® 4 EATON Powerware 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com

Summary of the content on the page No. 11

Chapter 2 Safety Warnings IMPORTANTSAFETYINSTRUCTIONS SAVETHESEINSTRUCTIONS Thismanualcontainsimportantinstructionsthatyoushouldfollowduringinstallationand maintenanceoftheUPSandbatteries.Pleasereadallinstructionsbeforeoperatingthe equipmentandsavethismanualforfuturereference. DANGER ThisUPScontainsLETHALVOLTAGES.Allrepairsandserviceshouldbeperformedby AUTHORIZEDSERVICEPERSONNELONLY.ThereareNOUSERSERVICEABLEPARTS insidetheUPS. WARNING S ThisUPScontainsitsownenergysource(batteries).TheUPSoutputma

Summary of the content on the page No. 12

SAFETY WARNINGS Consignes de Sécurité CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES CONSIGNES DE SÉCURITÉ IMPORTANTES DANGER! CetonduleurcontientdesTENSIONSMORTELLES.Touteopérationd’entretienetde réparationdoitêtreEXCLUSIVEMENTCONFIÉEAUNPERSONNELQUALIFIÉAGRÉÉ. AUCUNEPIÈCERÉPARABLEPARL’UTILISATEURnesetrouvedansl’onduleur. WARNING S Cetonduleurrenfermesapropresourced’énergie(batteries).Lesprisesdesortie peuventêtresoustensionmêmelorsquel’onduleurn’estpasbranch

Summary of the content on the page No. 13

SAFETY WARNINGS Advertencias de Seguridad INSTRUCCIONES DE SEGURIDAD IMPORTANTES GUARDE ESTAS INSTRUCCIONES ESTE MANUAL CONTIENE INSTRUCCIONES DE SEGURIDAD IMPORTANTES PELIGRO EsteSIEcontieneVOLTAJESMORTALES.Todaslasreparacionesyelserviciotécnicodeben serefectuadosSOLAMENTEPORPERSONALDESERVICIOTÉCNICOAUTORIZADO.Nohay NINGUNAPARTEQUEELUSUARIOPUEDAREPARARdentrodelSIE. WARNING S EsteSIEcontienesupropiafuentedeenergía(lasbaterías).Losreceptáculosdesalida puedentransmitircorrienteeléctricaauncuandoel

Summary of the content on the page No. 14

SAFETY WARNINGS ® 8 EATON Powerware 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www.powerware.com

Summary of the content on the page No. 15

Chapter 3 UPS Setup This chapter describes: S Equipment inspection S Floor loading and clearances S Unloading the cabinet(s) The instructions are intended for the chief operator/system supervisor, electrical consultants, and installation electricians. Local regulations and electrical code must be followed during the UPS installation. Inspecting the Equipment If any equipment has been damaged during shipment, keep the shipping and packing materials for the carrier or place of purchase and file a

Summary of the content on the page No. 16

UPS SETUP Floor Loading When planning the installation, consider the UPS weight for floor loading. The strength of the installation surface must be adequate for point and distributed loadings. The approximate weights are shown in the following table. StandardModelFloorLoadings Maximum PointLoading Powerware9355 2 2 Weight(lb) lb/in (kg/cm ) 2-HighUPS 381lb(173kg) 95(6.7) 3-HighUPS-32 587lb(266kg) 147(10.3) 3-HighUPS-64 619lb(281kg) 155(10.9) 2-HighEBM 480lb(218kg) 120(8.4) 3-HighEBM 710lb(322kg)

Summary of the content on the page No. 17

UPS SETUP Unloading the Cabinet(s) The following tools are required for unloading the cabinet(s): S 15 mm wrench or socket S 7 mm nut driver or socket CAUTION TheUPSandEBMareheavy(seepage10).Unloadingthecabinetsrequiresatleasttwo peopletosafelyremovethecabinetsfromthepallet. Three-High Cabinets To remove a three-high UPS or EBM from the shipping pallet: 1. Remove the two M10 bolts securing the stabilizing bracket to the pallet (see Figure 2). M10Bolts Figure2.RemovingtheStabilizingBracketBolts ®

Summary of the content on the page No. 18

UPS SETUP 2. Remove the four M4 screws securing the stabilizing bracket to the cabinet rear panel and remove the bracket (see Figure 3). Retain the hardware for later use. NOTE Besuretoretainthestabilizingbracketandhardwareforlaterre-assemblyontothe cabinet. 3. Remove the three M10 bolts securing the rear shipping pad to the pallet and remove the shipping pad. NOTE Holdthebackofthecabinetsothattheboltscanberemovedeasilywithoutthe cabinetrollingbackward. 4. Remove the two M10 bolts securing the f

Summary of the content on the page No. 19

UPS SETUP NOTE Besuretosupportthefrontandbackofthecabinetwhenrollingitoffthepalletto preventtipping. 5. Slowly roll the cabinet toward the rear of the pallet. Once the pallet tilts, continue rolling the cabinet down the pallet until the cabinet touches the floor (see Figure 4). Figure4.UnloadingtheCabinet 6. With the UPS supported, slowly pull the pallet away from the UPS (see Figure 5). Figure5.RemovingthePallet 7. Roll the cabinet to the desired location. 8. Continue to “Selecting an Installat

Summary of the content on the page No. 20

UPS SETUP Two-High UPS Cabinet To remove a two-high UPS from the shipping pallet: 1. Remove the M10 bolt securing the vertical bracket to the pallet (see Figure 6). 2. Remove and retain the three M4 screws securing the vertical bracket to the UPS. Remove the vertical bracket. M4Screws M10Bolt Figure6.RemovingtheVerticalBracket 3. Reinstall the M4 screws to the UPS (see Figure 7). M4Screws Figure7.ReinstallingtheM4Screws ® 14 EATON Powerware 9355 UPS (10/15 kVA) User’s Guide S 164201594 Rev B www


Alternative user manuals
# User manual Category Download
1 Powerware 208/120V User manual Power Supply 8
2 Powerware 3110 User manual Power Supply 33
3 Powerware 400/230V User manual Power Supply 4
4 Powerware 4500 User manual Power Supply 5
5 Powerware 3115 User manual Power Supply 39
6 Powerware 5075 kVA User manual Power Supply 0
7 Powerware 5110 User manual Power Supply 24
8 Powerware 415/240V User manual Power Supply 0
9 Powerware 380/220V User manual Power Supply 0
10 Powerware 5105 User manual Power Supply 61
11 Powerware 5140 User manual Power Supply 0
12 Powerware 30-160kVA User manual Power Supply 5
13 Powerware 5115A USB User manual Power Supply 4
14 Powerware 5115RM User manual Power Supply 1
15 Powerware 8 - 15 kVA User manual Power Supply 9
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2