APC Smart-UPS URTA48XLBPJ user manual

User manual for the device APC Smart-UPS URTA48XLBPJ

Device: APC Smart-UPS URTA48XLBPJ
Category: Power Supply
Manufacturer: APC
Size: 1.27 MB
Added : 10/28/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for APC Smart-UPS URTA48XLBPJ. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with APC Smart-UPS URTA48XLBPJ.

For your convenience

If looking through the APC Smart-UPS URTA48XLBPJ user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual APC Smart-UPS URTA48XLBPJ on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual APC Smart-UPS URTA48XLBPJ to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
APC Smart-UPS URTA48XLBPJ User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual APC Smart-UPS URTA48XLBPJ but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to APC Smart-UPS URTA48XLBPJ. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 9

Terminal Mode Configuration Terminal Mode Configuration This configuration affects the accuracy of the runtime calculations that the UPS performs while run- ning on battery power. ® Settings are made through supplied PowerChute Business Edition or Terminal Mode. Terminal mode can only be used with the serial cable provided with the UPS. If using a USB cable, disconnect the USB cable from the UPS, and connect the serial cable to the UPS before using the terminal program. Note Shown below is an

Summary of the content on the page No. 10

TVSS GND TVSS GND TVSS GND Storage, Transport, and Service Refer to the “Troubleshooting” section in the UPS user manual to solve minor battery pack or UPS installation and operation problems. Refer to www.apc.com with complex battery pack or UPS problems. Storage, Transport, and Service Storage Store the battery pack covered in a cool, dry location with the battery modules fully charged. At 5° to 113° F (–15° to 45° C), charge the battery modules every six months. To Install a Replacement Bat

Summary of the content on the page No. 1

®
APC Smart-UPS RT SURTA48XLBP/SURTA48XLBPJ
External Battery Pack User Manual
Introduction/Before Installation
About this Manual
®
The APC Smart-UPS RT external battery pack (SURTA48XLBP or SURTA48XLBPJ) connects to
the APC Smart-UPS RT uninterruptible power supply (SURTA1500XL and SURTA2000XL, or
SURTA1500XLJ). Together these units provide extended protection against blackouts, brownouts,
sags and surges reaching your computers, servers, and other sensitive electronic equipment.
Illustration

Summary of the content on the page No. 2

Pre-installation Procedure 4. Place the battery pack where it will be used. – Ensure that air vents on the front and rear of the unit are not blocked. – Do not operate the battery pack where there is excessive dust or the temperature or humidity are outside the specified limits. 40°C 95% 104°F 0% 2.5 2.5 cm cm Pre-installation Procedure 1. Once the battery pack is at the installation site, remove the top cover  and battery modules  to lighten the load and prepare the battery pack to be in

Summary of the content on the page No. 11

Storage, Transport, and Service 3. To lighten the load, remove the battery modules before transporting the battery pack to another location. a. Remove the bezel  and battery covers . b. Disconnect  and remove  the battery modules.     Service Always DISCONNECT THE BATTERY MODULES before shipping the battery pack to be in compliance with U.S. Department of Transportation (DOT) regulations. Caution If the battery pack requires service do not return it to the dealer. Follow these steps:

Summary of the content on the page No. 12

Limited Warranty American Power Conversion (APC) warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its own sole option, any such defective products. To obtain service under warranty you must obtain a Returned Material Authorization (RMA) number from customer support. Products must be returned with transportation charges prepaid and must be

Summary of the content on the page No. 3

Tower Installation Tower Installation When installing the UPS and battery pack(s) as a tower configuration, they must be joined together with stabilizing feet and clips. Failure to comply to this instruction may result in bodily injury or equipment damage. Caution When installing the UPS and battery pack(s) as a tower configuration, battery pack(s) must be installed to the right of the UPS when facing the front of the UPS. Failure to follow this instruction could result in cabling shortage.

Summary of the content on the page No. 4

Tower Installation 2. Complete this step if adding battery pack(s) to an existing tower system. a. Turn Off the UPS and disconnect all equipment. Refer to the UPS user manual for instructions. b. Remove bezels, battery covers, and battery modules from all previously installed equipment. For additional instructions, refer to the UPS user manual and “Transporting the Battery Pack to Another Location” on page 10. c. Remove the feet  from the last battery pack . d. Attach and mount the feet to t

Summary of the content on the page No. 5

Rack-mount Installation c. Install  and connect  the battery pack battery modules. d. Install the battery pack covers  and bezel .  5. Go to “Terminal Mode Configuration” on page 9 to configure the UPS to recognize the battery pack(s). Rack-mount Installation 1. Complete this step if this is a new installation of the UPS with battery pack(s). a. Place the UPS on its side to remove the battery. To remove the battery, refer to the “Battery Replacement Instructions” procedure in the UPS u

Summary of the content on the page No. 6

Rack-mount Installation 3. Install the battery pack(s) and the UPS in the rack. The UPS must be installed ABOVE the battery pack(s) when in a rack. Failure to follow this instruction could result in cabling shortage. Note a. Refer to the installation sheet contained in the SURTRK rail box for instructions on how to install the cleats, rack-mount brackets, and labels on the UPS and battery pack(s). b. Refer to the installation sheet contained in the SURTRK rail box for instructions on how to

Summary of the content on the page No. 7

Battery Pack and UPS Connection Procedure b. Install the UPS and battery pack battery covers  and bezels .  6. Go to “Terminal Mode Configuration” on page 9 to configure the UPS to recognize the battery pack(s). Battery Pack and UPS Connection Procedure The battery pack is equipped with the following connectors. Refer to the UPS user manual for UPS connector types and definitions. Connectors Type Description TVSS screw The UPS and battery pack features a Transient Voltage Surge-suppres- s

Summary of the content on the page No. 8

TVSS GND TVSS GND TVSS GND TVSS GND TVSS GND TVSS GND Battery Pack and UPS Connection Procedure 1. Connect the green/yellow ground wire(s)  to the TVSS screw locations  between the UPS and battery pack, or between battery packs as shown.      2. To connect the battery pack to the UPS and to connect battery packs to one another: a. Remove the UPS battery connector plate . b. Insert the adjacent battery pack connector cable plug  into the connector receptacle  on the UPS. c. If applica


Alternative user manuals
# User manual Category Download
1 APC 208 Vac User manual Power Supply 8
2 APC 1400XLT User manual Power Supply 23
3 APC 15A User manual Power Supply 0
4 APC 120V User manual Power Supply 5
5 APC 2200XLT User manual Power Supply 24
6 APC 2000XL User manual Power Supply 15
7 APC 1000VA User manual Power Supply 24
8 APC 1500 VA User manual Power Supply 46
9 APC 300 User manual Power Supply 404
10 APC 5000VA User manual Power Supply 60
11 APC 500 User manual Power Supply 26
12 APC 3000VA User manual Power Supply 12
13 APC 3000T User manual Power Supply 1
14 APC 600 User manual Power Supply 64
15 APC 2AP9604S User manual Power Supply 1
16 Sony AC U50A User manual Power Supply 5
17 Sony AC LS1 User manual Power Supply 2
18 Sony NP-FM30 User manual Power Supply 35
19 Sony NP FX101 User manual Power Supply 1
20 Sony NH-AAA-DA User manual Power Supply 2