Omega Engineering PX2670 user manual

User manual for the device Omega Engineering PX2670

Device: Omega Engineering PX2670
Category: Satellite Radio
Manufacturer: Omega Engineering
Size: 0.04 MB
Added : 9/17/2014
Number of pages: 7
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega Engineering PX2670. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega Engineering PX2670.

For your convenience

If looking through the Omega Engineering PX2670 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega Engineering PX2670 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega Engineering PX2670 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega Engineering PX2670 User manual - Online PDF
Advertisement
« Page 1 of 7 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega Engineering PX2670 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega Engineering PX2670. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Guide
http://www.omega.com
email: info@omega.com
MODEL PX2670
Low Pressure Tranducers
and Transmitters

Summary of the content on the page No. 2

 OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.com For immediate techincal or application assistance: USA and Canada Sales Service: 1-800-826-6342/1-800-TC-OMEGASM Customer Service: 1-800-622-2378/1-800-62

Summary of the content on the page No. 3

General Information The PX2670 Series pressure transducers and transmitters sense differential pressure and gage (static) pressure and convert this pressure difference to a proportional high level analog output for both unidirectional and bidirectional pressure ranges. Two versions are offered: the voltage model transducer with 0 to 10 VDC output and the current model transmitter with 4 to 20 mA output. Environmental Conditions The PX2670 Series is designed to be operated and stored in the foll

Summary of the content on the page No. 4

The Model 267 voltage output is a 3-wire circuit, with three terminals available for wiring (see Figure 1). The -Excitation and -Output are commoned on the circuit (see Figure 2A). The 267 voltage output can operate from either AC (9-30 VAC) or DC (12-40 VDC) excitation. The 267 has a 0-10 VDC output, calibrated at the Factory. PX 2670 PX 2670 Figure 2 Figure 2A Transducer Transmitter (Voltage) (4 to 20 mA) _ _ + + + + + + Power Load Power Load (Monitor) (Monitor) Supply Supply _ _ _ _ Current

Summary of the content on the page No. 5

Zero Adjustment - Voltage While monitoring the voltage between the positive output (+OUT) and common (-OUT), and with both ports open to atmosphere, the zero may be adjusted. For unidirectional pressure ranges, turn the zero adjustment screw until a reading of 0.050 VDC is achieved. For bidirectional pressure ranges set to 5 VDC. Zero Adjustment - Current While monitoring the current output with both ports open to atmosphere, the zero may be adjusted. For unidirectional pressure ranges, turn

Summary of the content on the page No. 6

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maxi- mum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Department

Summary of the content on the page No. 7

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA...Of Course! TEMPERATURE Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies Wire: Thermocouple, RTD & Thermistor Calibrators & Ice Point References Recorders, Controllers & Process Monitors Infrared Pyrometers PRESSURE, STRAIN AND FORCE Transducers & Strain Gauges Load Cells & Pressure Gauges Displacement Transducers Instrumentation & Accessories FLOW/LEVEL Rotameters, Gas Mass Fl


Alternative user manuals
# User manual Category Download
1 Omega Engineering PHTX-11 User manual Satellite Radio 4
2 Omega Engineering TX801M User manual Satellite Radio 3
3 Omega Engineering LDX-2 User manual Satellite Radio 0
4 Omega Engineering TX801D RTD User manual Satellite Radio 0
5 Omega Engineering M-4066 User manual Satellite Radio 0
6 Sony DRN-XM01HK2 User manual Satellite Radio 1
7 Sony 3-873-945-12 (1) User manual Satellite Radio 0
8 Sony SA-VE812ED User manual Satellite Radio 1
9 Sony DRN-XM01R2 User manual Satellite Radio 0
10 Sony AIR-SA17TI User manual Satellite Radio 6
11 Sony SAT-HD100 User manual Satellite Radio 2
12 Sony 346 User manual Satellite Radio 0
13 Sony E672 User manual Satellite Radio 0
14 Sony User manual Satellite Radio 0
15 Sony SA-VE815ED User manual Satellite Radio 5