Datalogic Scanning MAGELLAN 1000I user manual

User manual for the device Datalogic Scanning MAGELLAN 1000I

Device: Datalogic Scanning MAGELLAN 1000I
Category: Scanner
Manufacturer: Datalogic Scanning
Size: 0.89 MB
Added : 9/25/2014
Number of pages: 160
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Datalogic Scanning MAGELLAN 1000I. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Datalogic Scanning MAGELLAN 1000I.

For your convenience

If looking through the Datalogic Scanning MAGELLAN 1000I user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Datalogic Scanning MAGELLAN 1000I on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Datalogic Scanning MAGELLAN 1000I to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Datalogic Scanning MAGELLAN 1000I User manual - Online PDF
Advertisement
« Page 1 of 160 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Datalogic Scanning MAGELLAN 1000I but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Datalogic Scanning MAGELLAN 1000I. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
Magellan 1000i
Omni-Directional Imaging Scanner
Product Reference Guide

Summary of the content on the page No. 2

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic products are hereby granted a non-exclusive, re

Summary of the content on the page No. 3

Table of Contents About This Manual ............................................................................................................... 1-1 Manual Conventions ....................................................................................................... 1-1 Connecting the Scanner ....................................................................................................... 1-2 Programming ..............................................................................

Summary of the content on the page No. 4

Bar/Space Polarity .................................................................................... 3-27 Wand Idle State ........................................................................................ 3-27 Signal Speed ............................................................................................ 3-28 Transmit Trailing Noise .............................................................................. 3-28 Transmit Leading Noise .......................................

Summary of the content on the page No. 5

Code 39 Full ASCII .......................................................................................................5-25 Length Control .............................................................................................................5-26 Code 39 Length 1, Length 2 Programming Instructions ......................................................5-27 Quiet Zones .................................................................................................................5-27 Cod

Summary of the content on the page No. 6

Minimum Reads ........................................................................................................... 5-63 Optical and Read Performance Parameters ..............................................................................A-1 Scanner Dimensions ............................................................................................................A-1 Physical Properties ....................................................................................................

Summary of the content on the page No. 7

Chapter 1 Getting Started ® The Magellan 1000i Omni-Directional Imaging Scanner offers hands-free scanning for small, easily handled items and handheld scanning for bulkier items. Its aggressive imaging perfor- mance and intuitive operation reduces user training and speeds checkout for better customer service. About This Manual This manual presents advanced user information which includes connection, programming, product and cable specifications, and other useful references. For additional in

Summary of the content on the page No. 8

K e W y e b d o a g r d e Getting Started Connecting the Scanner The scanner kit you ordered to match your interface should provide a compatible cable for your installation. Use the appropriate instructions below to connect the scanner to the terminal, PC or other host device. Upon completing the connection via the appropriate interface instructions below, proceed to the Interface Related Features section of this manual and scan the bar code to select the correct interface type. RS-232 Seri

Summary of the content on the page No. 9

Programming Wand Emulation Connection — Connect the scanner to the appropriated port on the ter- minal/PC using the correct cable for the interface type you ordered. Reference Figure 2. IBM Connection — Connect the scanner to the IBM port on the terminal/PC using the cor- rect IBM cable. Reference Figure 2. Keyboard Wedge Connection — Before connection, turn off power to the terminal/PC. The Keyboard Wedge cable has a ‘Y’ connection from the scanner. Connect the female to the male end from the

Summary of the content on the page No. 10

Getting Started LED and Beeper Indicators The scanner’s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner. The tables below list these indications. One exception to the behaviors listed in the tables is that the scanner’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming bar code labels. Green LED Indications LED INDICATION COMMENT INDIC

Summary of the content on the page No. 11

Error Codes Error Codes Upon startup, if the scanner flashes its indicator LED or sounds an unexpected series of beep tones (other than normal power-up indications), this means the scanner has not passed its auto- 1 matic Selftest and has entered FRU isolation mode. If the scanner is reset or the trigger is pulled, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found. NUMBER OF LED FLASHES/ ERROR CORRECTIVE ACTION BEEPS 1 Conf

Summary of the content on the page No. 12

Getting Started NOTES ® 1-6 Magellan 1000i

Summary of the content on the page No. 13

Chapter 2 General Features Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession). START / END PROGRAMMING BARCODES 0.1 Second 0.2 Second 0.3 Second 0.4 Second DEFAULT 0.5 Second 0.6 Second Product Reference Guide 2-1

Summary of the content on the page No. 14

General Features Double Read Timeout — cont. START / END PROGRAMMING BARCODES 0.7 Second 0.8 Second 0.9 Second 1 Second ® 2-2 Magellan 1000i

Summary of the content on the page No. 15

Label Gone Timeout Label Gone Timeout This feature sets the time after the last label segment is seen before the scanner prepares for a new label. START / END PROGRAMMING BARCODES Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Tim- eout,” followed by the three digits (zero padded) from the

Summary of the content on the page No. 16

General Features Sleep Mode This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode. START / END PROGRAMMING BARCODES 15 Seconds 30 Seconds 1 Minute 2 Minutes 3 Minutes 4 Minutes 5 Minutes ® 2-4 Magellan 1000i

Summary of the content on the page No. 17

Sleep Mode Sleep Mode — cont. START / END PROGRAMMING BARCODES 6 Minutes 7 Minutes 8 Minutes 9 Minutes 10 Minutes DEFAULT 12 Minutes 15 Minutes 30 Minutes 1 Hour Product Reference Guide 2-5

Summary of the content on the page No. 18

General Features LED and Beeper Indicators Power On Alert Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation. START / END PROGRAMMING BARCODES Disable Enable DEFAULT ® 2-6 Magellan 1000i

Summary of the content on the page No. 19

LED and Beeper Indicators Good Read: When to Indicate This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are: • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read = Indicate after CTS goes inactive, then active This option (Indicate after CTS goes inactive, then active), which uses CTS, is only valid for RS-232 inter- faces. NOTE START / END PROGRAMMING BARCODES After De

Summary of the content on the page No. 20

General Features Good Read Beep Control This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code. START / END PROGRAMMING BARCODES Disable Enable DEFAULT Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.) START / END PROGRAMMING BARCODES Low Medium DEFAULT High ³ 001402 ® 2-8 Magellan 1000i


Alternative user manuals
# User manual Category Download
1 Datalogic Scanning MAGELLAN 1000I User manual Barcode Reader 23
2 Datalogic Scanning 4420 User manual Scanner 68
3 Datalogic Scanning C-BOX 200 User manual Scanner 13
4 Datalogic Scanning C-BOX 310 User manual Scanner 7
5 Datalogic Scanning Datalogic Jet User manual Scanner 8
6 Datalogic Scanning 9500 User manual Scanner 165
7 Datalogic Scanning C-BOX 300 User manual Scanner 40
8 Datalogic Scanning 1000I User manual Scanner 4
9 Datalogic Scanning 9504 User manual Scanner 14
10 Datalogic Scanning DS1100 SH2347 User manual Scanner 2
11 Datalogic Scanning DLL2020 User manual Scanner 2
12 Datalogic Scanning DS1100 User manual Scanner 4
13 Datalogic Scanning DS1500 User manual Scanner 5
14 Datalogic Scanning DS2200 SH2348 User manual Scanner 10
15 Datalogic Scanning DS2200 User manual Scanner 27
16 Sony ICF-SC1 User manual Scanner 11
17 Sony SFM1 User manual Scanner 1
18 Sony ICF-SC1PC User manual Scanner 9
19 3M G4000 User manual Scanner 3
20 3M G4000 User manual Scanner 1