Our goal is to provide you with a quick access to the content of the user manual for Metrologic Instruments TECH 10. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Metrologic Instruments TECH 10.

For your convenience

If looking through the Metrologic Instruments TECH 10 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Metrologic Instruments TECH 10 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Metrologic Instruments TECH 10 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Metrologic Instruments TECH 10 User manual - Online PDF
Advertisement
« Page 1 of 21 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Metrologic Instruments TECH 10 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Metrologic Instruments TECH 10. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



















METROLOGIC INSTRUMENTS, INC.

®
TECH 10 LASER BAR CODE
ROJECTION SCANNER (1070)
P

INSTALLATION AND USER’S GUIDE

























November 2004
Printed in USA
00 - 02166A

Summary of the content on the page No. 2

Summary of the content on the page No. 3

LOCATIONS CORPORATE HEADQUARTERS North America Metrologic Instruments, Inc. Customer Service: 1-800-ID-METRO 90 Coles Road Tel: 856-228-8100 Blackwood, NJ 08012-4683 Fax: 856-228-6673 Email: info@metrologic.com Internet: www.metrologic.com EUROPEAN HEADQUARTERS Germany, Metrologic Instruments GmbH Tel: +49 89 89019 0 Middle East and Africa Dornierstrasse 2 Fax: +49 89 89019 200 82178 Puchheim b. Email: info@europe.metrologic.com Munich, Germany Germany Email: info@de.

Summary of the content on the page No. 4

TABLE OF CONTENTS Introduction ................................................................................................................................................................ 1 Scanner and Accessories .......................................................................................................................................... 1 Scanner Connections to the Host ....................................................................................................

Summary of the content on the page No. 5

INTRODUCTION ® Metrologic's TECH 10 laser bar code projection scanner is encased in a NEMA-12 steel case. The scanner's construction enables the scanner to operate in harsh surroundings, especially industrial environments. Water- resistant, shock-resistant, and rugged, the TECH 10 scanner is also fast, aggressive and reliable. It can register bar codes at a range of 203 mm – 559 mm (8" - 22") and can autodiscriminate among all common codes. Among the scanner’s many features is an Appl

Summary of the content on the page No. 6

SCANNER CONNECTIONS TO THE HOST To avoid potential problems, do not power up the scanner until the communication cable is secured to the host 1. Turn off the host system. 2. Locate the 19-pin female end of the scanner link cable and find the widest key located above pins L and A. Align this key with the corresponding key on the scanner box’s Mil spec connector. While pushing in on the connector, rotate the ring clockwise until it locks into place with a click. 3. Connect the o

Summary of the content on the page No. 7

CONFIGURATION OF THE SCANNER TO THE HOST SYSTEM The scanner is shipped from the factory programmed to a set of default conditions noted in the ScanSelect® Scanner Programming Guide by an asterisk that appears before the brief definition next to the bar code. In order for the scanner to communicate with the host system properly, it needs to be programmed to meet your specific scanning needs. Since each host system is unique, the scanner must be configured to match the host system requir

Summary of the content on the page No. 8

PARTS OF THE SCANNER Becoming familiar with the features of the TECH 10® scanner will help when operating the scanner. The following illustration and list explain the pertinent parts. Figure 1 1. Green and Red LEDs When the green LED is on, this shows that the unit is receiving power and the laser is on. When the red LED flashes on, the scanner has read a bar code successfully. When the red light turns off, communication to the host

Summary of the content on the page No. 9

INSTALLATION OF THE STAND With the Metrologic stand (Part #45-45479), the scanner can be positioned in a vertical orientation. To use this stand, four 6-32 x ½" machine screws and two #10 panhead wood screws will need to be purchased. The maximum distance the screws should go into the scanner is ½ inch. 1. Lay the scanner face down on a clean cloth to prevent any scratches from occurring on the output window. Position the scanner so the red and green LEDs are pointed toward you.

Summary of the content on the page No. 10

Figure 2 6

Summary of the content on the page No. 11

LABELS A label is inside the window of the scanner noting that this device is a CDRH Class IIA laser product and IEC 825 LASERKLASSE 1. Also, on the scanner is a label on the back of the unit. This label contains information such as the model number, date of manufacture, and serial number. The following are samples of the labels that are found on the unit. Scanning bar codes The depth of field for the scanner is 254 mm to 559 mm (10" to 22") from the scanner window. Pass the

Summary of the content on the page No. 12

MAINTENANCE Smudges or dirt that appears on the scanner window can interfere with proper scanning. Therefore, only maintenance required is an occasional cleaning of the glass window. 1. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. 2. Gently wipe the scanner window. 8

Summary of the content on the page No. 13

APPENDIX A Specifications Application: Universal Industrial Scanner Light Source: Visible Laser Diode 650 ± 5nm Laser Class: CDRH: CLASS IIa; EN 60825 Class 1 Certifications: CE, UL listed for US and Canada EMC: FCC, ICES-003 & EN 55022 Class A Mechanical Dimensions: 311 mm x 262 mm x 108 mm (12.25" L x 10.32" W x 4.25" D) Weight: 5.19 kg. (11.45 lbs.) without cable Orientation: May be used in any orientation Mounting: Back plate mount or vertical stand Top Cover: NEMA-12

Summary of the content on the page No. 14

APPENDIX A (CONTINUED) Operational Depth of Scan Field: 254 mm to 559 mm (10" to 22") Scan Speed: 1,250 scan lines per second Scan Pattern: 25 line omnidirectional Exit Angle: 12° down off perpendicular of scan window Indicators: LED: red = good read; green = laser on Beeper Operation: Selection of 3 tones for “Good Read” Maintenance Required: Clean window periodically Decode Capability: Autodiscriminates System Interfaces: RS232C; Light Pen Emulation; OCIA; RS422 Print Contrast

Summary of the content on the page No. 15

APPENDIX B Pin Assignments for the Mil spec Connector Each TECH 10®scanner has a 19-pin male Mil spec connector that is on the side of the unit. To connect the scanner to the host device, use a communication cable with a female Mil spec connector. The communication cable may include a power transformer or it may be designed to draw power directly from the host device. This item can be ordered when the scanner is purchased. The following is a list of the pin assignments. The pin n

Summary of the content on the page No. 16

APPENDIX C Limited Warranty ® ® The Tech 10 scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility Tech 10 . ® The Tech 10 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants ® and represents that all Tech 10 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S. Federal, state and local laws, regulations and ordinances per

Summary of the content on the page No. 17

APPENDIX D Notice This equipment has been tested and found to comply with limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communicatio

Summary of the content on the page No. 18

APPENDIX D (CONTINUED) EUROPEAN STANDARD Warning This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures. Funkstöreigenschaften nach EN 55022:1998 Warnung! Dies ist eine Einrichtung der Klasse A. Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem fall kann vom Betrieber verlangt werden, angemessene Maßnahmen durchführen. Standard Europeo

Summary of the content on the page No. 19

Appendix E Patents “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No. 4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,607,156; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,923,281; 4,933,538; 4,960,985; 4,992,717; 5,015,833; 5,017,765; 5,059,779; 5,081,342; 5,117,098; 5,124,539; 5,130,520; 5,132,525; 5,140,144; 5,149,950; 5,180,904; 5,200,5

Summary of the content on the page No. 20

Index Germany (GmbH) ii, 12 A AC 2, 9 Good read 10 Green LED 4, 5 Application 9 Asia ii ASIC 1 H Assignments Headquarters ii pin 11 Host 2, 3, 4, 11 Humidity 10 B Bar code(s) 1, 3, 4, 7 I Beep 3 IEC 825 LASERKLASSE 1, 7 Beeper operation 10 Indicators LED 4, 5, 10 C Interfaces 10 Cable Installation communication 1, 2, 4, 11 Stand 5 CDRH class IIa 7 Internet ii Clean 8 Introduction 1 Compliance 2 Configuration 3 K Copyright ii Key 2 Curren


Alternative user manuals
# User manual Category Download
1 Metrologic Instruments 160 User manual Scanner 5
2 Metrologic Instruments FocusBT MS1633 User manual Scanner 15
3 Metrologic Instruments Cubit MS6520 Series User manual Scanner 66
4 Metrologic Instruments Cubit IS6520 Series User manual Scanner 83
5 Metrologic Instruments Genesis MS7580 User manual Scanner 44
6 Metrologic Instruments 185 User manual Scanner 0
7 Metrologic Instruments FOCUSE IS1650 User manual Scanner 3
8 Metrologic Instruments iQ160 User manual Scanner 0
9 Metrologic Instruments Hand-Held User manual Scanner 1
10 Metrologic Instruments FocusBT MS9535 User manual Scanner 387
11 Metrologic Instruments ARGUSSCANTM MS7220 User manual Scanner 4
12 Metrologic Instruments IS4813 User manual Scanner 2
13 Metrologic Instruments IS4823 User manual Scanner 0
14 Metrologic Instruments IS4910 Series User manual Scanner 0
15 Metrologic Instruments IS4825 User manual Scanner 2
16 Sony ICF-SC1 User manual Scanner 11
17 Sony SFM1 User manual Scanner 1
18 Sony ICF-SC1PC User manual Scanner 9
19 3M G4000 User manual Scanner 3
20 3M G4000 User manual Scanner 1