Opticon OPR 3001 user manual

User manual for the device Opticon OPR 3001

Device: Opticon OPR 3001
Category: Scanner
Manufacturer: Opticon
Size: 0.89 MB
Added : 4/1/2014
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Opticon OPR 3001. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Opticon OPR 3001.

For your convenience

If looking through the Opticon OPR 3001 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Opticon OPR 3001 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Opticon OPR 3001 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Opticon OPR 3001 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Opticon OPR 3001 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Opticon OPR 3001. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


OPR 3001
Rugged Handheld
Laser Scanner

Specifications Manual


Summary of the content on the page No. 2

Opticon OPR 3001 Specifications Manual All information subject to change without notice. Document History Model Number: OPR 3001 Specification Number: SS06106 Edition: Original Spec Number: 2 SS06080 Date: 2006-12-27 Copyright 2007 Opticon. All rights reserved. This manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic or machine readable form without prior written consent of Opticon. Limited Warranty and Disclaimer

Summary of the content on the page No. 3

Opticon OPR 3001 Specifications Manual Contents 1. Abstract....................................................................................................................................6 2. Overview ..................................................................................................................................6 3. Physical Features....................................................................................................................7 3.1. Dimensi

Summary of the content on the page No. 4

Opticon OPR 3001 Specifications Manual 8.2.1. Settings and Communication................................................................................................. 23 8.2.2. Interface Circuit...................................................................................................................... 23 8.3. Wedge Interface Specification .......................................................................................23 8.3.1. Settings and Communication...........

Summary of the content on the page No. 5

Opticon OPR 3001 Specifications Manual 16.1. Laser Safety...................................................................................................................38 16.2. Product Safety ...............................................................................................................38 16.3. EMC...............................................................................................................................38 16.4. RoHS ............................

Summary of the content on the page No. 6

Opticon OPR 3001 Specifications Manual 1. Abstract This manual provides specifications for the OPR 3001 handheld laser barcode scanner. 2. Overview The OPR 3001 is a rugged handheld laser barcode scanner with protection against dust and splashing water to ensure reliable operation in harsh environments. The OPR 3001 is enclosed in a rugged housing sealed to IP-54 standards that withstands repeated drops of up to two meters onto concrete. Short-wavelength red laser beams enhance t

Summary of the content on the page No. 7

Opticon OPR 3001 Specifications Manual 3. Physical Features 3.1. Dimensions W 68 X D 150 X H 155 mm (except protruding portion) 3.2. Weight 230g max (excluding cable). 4. Environmental Specifications 4.1. Operating Temperature and Humidity Temperature: -10 to +60° C Humidity: 5 to 90% RH 4.2. Storage Temperature and Humidity Temperature: -30 to +70° C Humidity: 5 to 90% RH 4.3. Ambient Light Immunity Decoding performance is guaranteed when the range of illumination on a ba

Summary of the content on the page No. 8

Opticon OPR 3001 Specifications Manual Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS: 0.9 Resolution: 0.25 mm Symbology: 9-digit Code-39 Quiet Zone: 10 mm N/W Ratio: 1:2.5 Distance: 100 mm from the edge of scanner Angle: α = 0° β = 15° γ = 0° Curvature: R = ∞ Power supply voltage: 6.0 V Direct light or specular reflection light from a source should be prevented from entering the acceptance area. 5. Electrical Specifications 5.1. Electrical Characteristics Par

Summary of the content on the page No. 9

Opticon OPR 3001 Specifications Manual 6. Optical Specifications 6.1. Laser Scanning Specification Parameter Specification Unit Light-emitting Element Red laser diode - Emission Wavelength 650 ±10 (25° C) nm Light Output 1.0 or less mW Scanning Method Bi-directional scanning - Scanning Speed 100 ±20 scans/s Scan Angle Scan angle: 54 ±5 ° Effective scan angle: 44 (Min) ° 6.2. Laser Scanning Standard 6.2.1. Laser Scanning Tilt Laser scanning tilt is the vertical difference be

Summary of the content on the page No. 10

Opticon OPR 3001 Specifications Manual 7. Technical Specifications The conditions for technical specifications are as follows, unless otherwise specified in each section. Conditions Ambient Temperature and Humidity 21º C/70º F, 60% RH Ambient Light 500 to 900 lx Background Barcode = black Space = white Margin = white Background of label = black Power Supply Voltage 6.0 V (RS-232C) / 5.0 V (USB and Wedge) Decoding Test Approve the performance when decoding is successful in all

Summary of the content on the page No. 11

Opticon OPR 3001 Specifications Manual 7.2. Scan Area and Resolution The depth of field is measured from the edge of the scanner. The scanning range is within the circular arc centered on the scan origin. Figure 3: Scan area and resolution (in mm) Resolution Symbology PCS Quiet Zone Digit Decode depth (mm) 1.0 mm CODE-39 0.9 25 mm 1 30 - 590 0.5 mm CODE-39 0.9 18 mm 3 10 - 360 0.25 mm CODE-39 0.9 10 mm 8 10 - 200 0.15 mm CODE-39 0.9 7 mm 10 10 - 90 0.127 mm CODE-39

Summary of the content on the page No. 12

Opticon OPR 3001 Specifications Manual 7.3. Pitch, Skew, and Tilt 7.3.1. Pitch Angle α = ±35° Figure 4: Pitch 12 α =35° α =35°

Summary of the content on the page No. 13

Opticon OPR 3001 Specifications Manual 7.3.2. Skew Angle and Dead Zone Skew angle: β = ±50° (Excluding dead zone) Dead zone: β = ±8° (There are some areas in which decoding fails due to specular reflection) Figure 5: Skew angle and dead zone 13

Summary of the content on the page No. 14

Opticon OPR 3001 Specifications Manual 7.3.3. Tilt Angle γ = ±20° Figure 6: Tilt angle Conditions Barcode Sample: OPTOELECTRONICS Test Sample Distance: 60 mm from the edge of the scanner Label: Pitch Angle, Skew Angle, Dead Zone PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code-39, Quiet Zone = 10 mm N/W Ratio = 1:2.5 Tilt Angle PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm Angle: Pitch Angle: Skew Angle β = +15°, Tilt Angle γ = 0° T

Summary of the content on the page No. 15

Opticon OPR 3001 Specifications Manual 7.4. Curvature With 8-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥15 mm. With 13-digit JAN/UPC/EAN barcodes, decoding performance is guaranteed when R ≥20 mm. Figure 7: Curvature Conditions Barcode Sample: OPTOELECTRONICS Test Sample PCS = 0.9, Resolution = 0.26 mm, Quiet Zone = 10 mm Distance: 60 mm from the edge of the scanner Angle: Skew Angle β = +15° 15

Summary of the content on the page No. 16

Opticon OPR 3001 Specifications Manual 8. Interface Specifications 8.1. RS-232C Interface Specification 8.1.1. Settings and Communication Reading menu barcodes [ZZ] + [U2] + [ZZ] can set the RS-232C interface default. Item [U2] setting Baud rate 9600 BPS Start/stop bits 1 bit Data bits 8 bits Parity bits No parity Handshaking No handshake Flow Control Time Out Indefinitely • You can change the communication condition using the menu barcode. 8.1.2. Signal Level Signal Name I

Summary of the content on the page No. 17

Opticon OPR 3001 Specifications Manual 8.1.3. Interface Circuit Figure 8: Interface circuit 8.1.4. Character Format Figure 9:Character format (same for both sending and receiving) 17

Summary of the content on the page No. 18

Opticon OPR 3001 Specifications Manual 8.1.5. Communication Format Figure 10: Communication format 8.1.6. Handshaking Select handshaking options using the menu or command listed below. Handshaking Menu/Command No handshake P0 BUSY/READY P1 MODEM P2 ACK/NAK P3 ACK/NAK NO RESPONSE P4 a) No Handshaking The scanner attempts the communication regardless of the state of the host computer. Figure 11: No handshaking b) BUSY/READY The scanner and the host computer notify each o

Summary of the content on the page No. 19

Opticon OPR 3001 Specifications Manual The scanner stays ON (is able to receive data) except during certain parts of the process, such as receiving data (buzzer command execution), transmitting data, and menu processing. The scanner checks the CTS line before transmitting data. When it is ON, the scanner transmits data. When it is OFF, the scanner waits for it to turn ON within a set time. The scanner will abort transmission with an error indication (buzzer) when the CTS line is no

Summary of the content on the page No. 20

Opticon OPR 3001 Specifications Manual c) MODEM The scanner turns CS line ON before transmitting data. Other processes are the same as BUSY/READY. Figure 15: Modem transmit data 20


Alternative user manuals
# User manual Category Download
1 Opticon CRD972X User manual Scanner 6
2 Opticon Laser User manual Scanner 18
3 Opticon LGZ 7225 User manual Scanner 1
4 Opticon LMD 1135 User manual Scanner 11
5 Opticon NFT 1125 User manual Scanner 4
6 Opticon LH2 User manual Scanner 1
7 Opticon LPN 1736 User manual Scanner 2
8 Opticon LPR5627 User manual Scanner 0
9 Opticon NFT 2135 User manual Scanner 2
10 Opticon OPR 2001 User manual Scanner 591
11 Opticon NFT 2100 User manual Scanner 1
12 Opticon OPL 9712 User manual Scanner 14
13 Opticon OPL972X User manual Scanner 12
14 Opticon LPN5627 User manual Scanner 0
15 Opticon OPT-6125 User manual Scanner 134
16 Sony ICF-SC1 User manual Scanner 11
17 Sony SFM1 User manual Scanner 1
18 Sony ICF-SC1PC User manual Scanner 9
19 3M G4000 User manual Scanner 3
20 3M G4000 User manual Scanner 1