Summary of the content on the page No. 1
TC8275 Series
TC8277 Series
TC8278 Series
®
VidQuad Color Video Processors
Philips
Communication &
Security Systems
Instructions for Use
Summary of the content on the page No. 2
16. Servicing - Do not attempt to service this unit yourself as opening or IMPORTANT SAFEGUARDS removing covers may expose you to dangerous voltage or other hazards. Refer all servicing to qualified service personnel. 1. Read Instructions - All the safety and operating instructions should be read before the unit is operated. 17. Damage Requiring Service - Unplug the unit from the outlet and refer servicing to qualified service personnel under the following 2. Retain Instructions - The safety an
Summary of the content on the page No. 3
SAFETY PRECAUTIONS SECURITE CAUT IO N AT T E NT IO N R ISK O F EL EC T R IC RIS Q UE DE C H O C E L E C T R IQ UE . S H O CK. DO NO T O P E N ! N E PA S O U VR IR . Danger: Pour ‚éviter tout risque d'électrocution, ne pas Caution: To reduce the risk of electrical shock, ouvrir le boîtier. Il n'y a pas de pièces remplaçables à do not open covers. No user serviceable parts inside. l'intérieur. Pour toute révision, s'adresser à un Refer servicing to qualified service personnel technicien spéc
Summary of the content on the page No. 4
SICHERHEITSVORKEHRUNGEN PRECAUCIONES DE SEGURIDAD VO R S IC H T PR EC A U C IO N RIE S G O DE CHO Q U E R ISIK O EIN ES E L E K T R IS C H EN S CHL AG E S NICH T Ö F F N E N ! EL EC T R IC O . ¡N O AB R IR ! Precaucion: Para Reducir El Riesgo De Choque Eléctrico, VORSICHT: Um einen elektrischen schlag zu vermeiden, Favor No Abrir La Cubierta. Este Equipo No Consta De abdeckung nicht entfernen. Wartungen aller art Piezas O Partes Que Requieren Servicio O Mantenimiento. qualifiziertem person
Summary of the content on the page No. 5
CONTENTS 1 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . .5 2 SERVICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 3 DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . .5 AT T E NT IO N 4 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . .5 O B SER V E PR EC AU T IO N S F O R HA NDL ING 4.1 Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 E L E C TR O S TA TIC 4.2 Mounting . . . . . . . . . . . . . . . . . . . . . . . . .
Summary of the content on the page No. 6
4.3 Cover Removal 4.4 Video Inputs WARNING: Removal of the cover should All camera inputs should utilize 2:1 interlaced format only be performed by qualified service cameras to achieve a real-time update rate (30 frames-per- personnel--not user serviceable.The unit second) when used with line-locked cameras that have a should always be unplugged, before removing phase error of less than 5 degrees. the cover and remain unplugged while the cover is removed. 4.4.1 TC8275 Series Connect up to four c
Summary of the content on the page No. 7
5.1.1 Initiating Menu Programming 4.6 Alarm Inputs and Output To start a menu programming session, press the MENU (Accessory Output) button. 4.6.1 TC8277 Series and TC8278 Series The operator will be prompted to enter a password, The 609 mm (24 in) cable, with 15 pin connectors provided consisting of a three button sequence of the front panel ® with the VidQuad units, are for use with the mating alarm buttons. The password can be programmed by the input, output and accessory connectors. These ca
Summary of the content on the page No. 8
5.2.5 ZOOM Button 5.2 Monitor Operation Operates only on the MON-A monitor. Used to switch 5.2.1 Monitor Display Outputs from quad displays to full-screen displays on the Quad monitor, and also to zoom the full-screen displays. The front panel buttons can be used to operate either on the MON-A monitor display, or on the MON-B monitor Full-screen Display Selection display. The MON-A monitor displays a digitized image and If an active quadrant is first selected, displays the so Zoom and Freeze ope
Summary of the content on the page No. 9
Zoom During VCR Playback Quadrants will sequence between the two input cameras related to the quadrant, namely 1 and 5, 2 and 6, 3 and 7, To zoom a quadrant in the recorded VCR display on the and 4 and 8 respectively. MON-A monitor, select that quadrant as the active quadrant by using the arrow buttons. An asterisk (*) will To stop sequencing of one individual quadrant, use the indicate the active quadrant. Press ZOOM to zoom that arrow buttons to select the appropriate quadrant and press quadra
Summary of the content on the page No. 10
5.2.10 MON-B Monitor Display 5.3 Alarm Input Operation The secondary monitor output, designated as the MON-B The product is equipped with 4 alarm inputs (TC8277 monitor, is used for selecting analog full-screen displays of Series) or 8 alarm inputs (TC8278 Series), each associated any one of the eight camera inputs, or to display a with its corresponding video input. System action during an sequenced list of full-screen displays. The MON-B monitor active alarm includes on-screen indication of th
Summary of the content on the page No. 11
5.3.6 Video Loss Action page. When that camera quadrant is next sequenced it will display a blank image with the video loss warning message. Upon video loss to any input, the corresponding camera Sequence lists are not automatically changed as a result of image on the MON-A display is automatically frozen, and a video loss. Cameras with video loss can still be selected for video loss warning message, "VDL" is displayed on the display on the MON-B monitor screen, which will be blanked correspondi
Summary of the content on the page No. 12
ON S 9404002A E Front Panel - TC8275 Series Ca m e ra 1 V ideo 1 V ideo 2 Ca m e ra 2 Ca m e ra 3 V ideo 3 V ideo 4 Ca m e ra 4 Ma in Mo n ito r QU A D CA M 1 CA M 2 C A M 3 CA M 4 VID E O OU T S 9 40 40 03 A E Typical Application - TC8275 Series 12
Summary of the content on the page No. 13
Front Panel - TC8277 Series and TC8278 Series and Back Panel - TC8277 Series Ca m e ra 2 Ca m e ra 3 Ca m e ra 1 Ca m e ra 4 D oor S w itc h A dditiona l C a m e r a s M AL AR M / O A A C C E S SORY CA M CA M CAM N 1 2 2 3 5 6 7 8 4 M V O B C N R A la r m O u tput R e la y C lo s ur e to V C R Monitor B (75 Ohm ) S 9505 017 A E Typical Application - TC8278 Series Alarm/Accessory Connector - Pin-Out Pin Function Pin Function Pin Function 3 5 4 2 1 1 Ground 6 Alarm 1 11 Alarm 2 2 Alarm
Summary of the content on the page No. 14
MA IN ME N U LIS T : C H A N G E PASSW O R D C H A N G E PASSW O R D CA M E RA T IT L E S CA M E RA T IT L E S AL AR M S AL AR M S RE M O T E RE M O T E SEQ U E N C E SEQ U E N C E CL O C K EXIT < SEL EC T > T O SEL EC T TITL E S M E N U S E Q U E NC IN G M E NU CL O C K M E NU R E MO T E ME N U AL AR M S M E N U C H A N G E PASSW O R D T IT L E D ISPL AY MO N -B L IS T T IM E /D AT E D IS P L A Y 1200 B A U D QU A D F U L L ON EN T E R N E W PA SSW O R D E D IT TITL E M O N-B DW E L L T IM E /D
Summary of the content on the page No. 15
Notes 15
Summary of the content on the page No. 16
3935 890 09611 98-42 © 1998 Philips Electronics N.V. Printed In U.S.A. © 1998 Philips Communication & Security Systems Inc. All Rights Reserved. Philips ® is a registered trademark of Philips Electronics N.V. Data subject to change without notice