Summary of the content on the page No. 1
DN500
OPERATORS MANUAL
Klark Teknik Group,
Klark Teknik Building,
Walter Nash Road,
Kidderminster.
Worcestershire.
DY11 7HJ.
England.
Tel:+44 1562 741515
Fax:+44 1562 745371
Email: sales@ktgplc.com
Website: www.klarkteknik.com
Summary of the content on the page No. 2
Summary of the content on the page No. 3
IMPORTANT SAFETY INSTRUCTIONS CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE AVIS: RISQUÉ DE CHOC ELETRIQUE. NE PAS OUVRIR These symbols are internationally accepted symbols that warn of potential hazards with electrical products. The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the pro
Summary of the content on the page No. 4
Summary of the content on the page No. 5
Walter Nash Road, Kidderminster, Worcestershire. DY11 7HJ. England Tel: +44 1562 741515. Fax: +44 1562 745371 Company Registration No: 2414018 SIGNAL PROCESSING BY DEFINITION DESIGNEDFOR APUREPERFORMANCE DECLARATION OF CONFORMITY We, Klark Teknik Group (UK) PLC of, Klark Teknik Building, Walter Nash Road, Kidderminster, Worcestershire, DY11 7HJ Declare that a sample of the following product:- Product Type Number Product Description Nominal Voltage (s) Current Freq DN500 Plus Dual Compress
Summary of the content on the page No. 6
Summary of the content on the page No. 7
Contents Klark Teknik DN500 1 After you have unpacked 3 Introduction 5 Instrument Familiarisation Front panel controls 7 Rear panel controls 8 Audio Connections 11 Using the DN500 13 Compression 14 Setting the Controls 15 Expansion 17 Setting the Controls 18 Limiting 19 Compression, Expansion and Limiting together 20 Application notes Linking to the Console 21 Using the Side Chain 22 De-essing 23 Technical Specification 25
Summary of the content on the page No. 8
Summary of the content on the page No. 9
. The Klark Teknik DN500 Thank you for selecting the Klark Teknik DN500 Plus dual compressor / limiter / expander. The unit continues the Klark Teknik tradition of providing superb audio performance, technical accuracy and rugged reliability. Precautions Do not install this unit in a location subjected to excessive heat, dust or mechanical vibration. Voltage Selection and Power Connection Connection is made by means of an IEC standard power socket. The rear panel text indicates the voltage
Summary of the content on the page No. 10
2
Summary of the content on the page No. 11
This Side Up After You Have Unpacked The Unit Save all the packing materials - they will prove valuable should it become necessary to transport or ship this product. Please inspect this unit carefully for any signs of damage incurred during transportation. It has undergone stringent quality control inspection and every possible effort has been made to ensure that it left the factory in perfect condition. If, however, the unit shows any signs of damage, please notify the transportation compa
Summary of the content on the page No. 12
4
Summary of the content on the page No. 13
Introduction Compression, expansion, limiting and peak clipping are four of the most valuable techniques available to the sound engineer. Not only can they solve many problems that can arise in day to day work, creative possibilities exist in abundance. The Klark Teknik DN500 Plus Dual Compressor/Limiter/Expander integrates all of these processes into a single, compact, rack mounting unit with two channel operation. Complete dynamic control over gain is the result, and also control over pro
Summary of the content on the page No. 14
6
Summary of the content on the page No. 15
Instrument Familiarisation: Front Panel Controls 6 7 8 9 15 13 17 18 1 2 3 4 5 10 11 12 14 16 The DN500 Plus Dual Compressor/Limiter/Expander consists of two identical channels, each with separate Compressor, Expander and Limiter sections. Compressor 1. Threshold determines the level above which gain reduction (compression) will take place, variable from +20dBu down to -30dBu. The Gain Reduction light bar graph meter indicates in decibels by how much the signal is compressed at any instant.
Summary of the content on the page No. 16
Expander 10. Threshold determines the level below which gain reduction will take place, variable from 20dBu down to -40dBu. Gain reduction BELOW a threshold level constitutes dynamic range EXPANSION. The Gain Reduction light bar graph meter indicates in decibels by how much the signal is expanded at any instant. 11. Ratio sets the degree of expansion applied below the threshold level, variable from 1:1 to 25:1. A ratio of 1:1 corresponds to zero expansion : Signal In = Signal Out. Aratio of
Summary of the content on the page No. 17
Instrument Familiarisation: Rear Panel Controls 22 23 19 26 115/220-240V 2 1 1 2 2 1 1 2 3 3 3 3 CUS NEUTRIK NEUTRIK NEUTRIK NEUTRIK 21 24 25 20 19. Mains is supplied via an IEC standard 3-pin connector. Acompatible power cord is supplied with the unit. 20. The mains fuse is located in a fuse holder fitted to the rear panel. Always replace with the correct type and rating as indicated on the unit. 21. Voltage selector switch. This unit is switchable between two nominal supply voltages, 110V
Summary of the content on the page No. 18
10
Summary of the content on the page No. 19
Audio Connections Input The input circuit is a transformerless, electronically balanced design which achieves a symmetry of better than- 50dB from 20Hz to 10kHz. If transformer balancing of the input is required, this must be specified at the time of order. It is not retrofittable. Output The standard output is unbalanced, but balancing transformers are available and may be retrospectively fitted. Please contact your Klark Teknik representative for more information. The output circuitry is
Summary of the content on the page No. 20
Side Chain/EXT Key Inputs The electronically balanced Side Chain inputs are on stereo ¼ inch typeAjack sockets, configured: TIP = HOT, RING = COLD, SLEEVE = EARTH. Inserting a mono jack plug will automatically unbalance the input. 1/4” Stereo Jack HOT COLD GND The sockets are internally normalled so that signal continuity is maintained when there is no jack plug inserted. If the unit is wired to a patchbay, then normalling must be carried out at the patchbay. Balanced Circuits Transformer o