Emerson 140 user manual

User manual for the device Emerson 140

Device: Emerson 140
Category: Stud Sensor
Manufacturer: Emerson
Size: 0.41 MB
Added : 8/28/2013
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson 140. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson 140.

For your convenience

If looking through the Emerson 140 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson 140 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson 140 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson 140 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson 140 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson 140. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Sheet
Models 140, 141, and 142
PN 51A-140/rev.E
December 2010
Conductivity Sensors
For additional information, please visit our website
at www.emersonprocess.com/raihome/liquid/.
CAUTION
CAUTION
SENSOR/PROCESS
BEFORE REMOVING THE SENSOR, be
APPLICATION COMPATIBILITY
absolutely certain the process pressure is
The wetted sensor materials may not be compatible reduced to 0 psig and the process tempera-
with process com position and operating conditions.
ture is at a safe level!
Appli

Summary of the content on the page No. 2

MODEL 140,141, and 142 sensors INSTALLATION INSTALLATION Keep 1/4 inch (6 mm) clearance between electrodes and piping. The electrodes must be completely sub- merged in the process liquid, i.e., to the level of the threaded connection. See Figure 1 for recommended orientation. ° ° If the sensor is installed in a side stream with the sample draining to open atmosphere, bubbles may accumulate on the electrodes. Trapped bubbles will cause errors. As bubbles accumulate, the conduc- FIGURE 1. Sens

Summary of the content on the page No. 3

MODEL 140,141, and 142 sensors INSTALLATION INSTALLATION – 141 SENSOR 1. Install the sensor in a 3/4-inch NPT weldalet or in a 1-inch pipe tee. 2. Remove the plastic shipping cap from the sensor. 3. Screw the sensor into the fitting. Use pipe tape on the threads. See Figure 3. DWG. NO. REV. 40014204 B FIGURE 3. Installing model 141 sensor INSTALLATION – 142 SENSOR 1. Install the sensor in a 3/4-inch NPT weldalet or in a 1-inch pipe tee. See Figure 4. 2. Remove the plastic shipping ca

Summary of the content on the page No. 4

MODEL 140 SERIES MODEL 140,141, and 142 sensors WIRING WIRING All 140 series sensors have a junction box mounted on the back of the sensor. Wiring connections in the junction box are shown in Figure 5. CABLE 9 8 7 6 5 GRAY 4 GRAY 3 2 1 Figure 5. Sensor junction box wiring. Terminals in the junction box are not numbered. 141 and 142 sensors have one gray wire (shown). The 140 sensor has two gray wires attached to the terminal. WIRE COLOR AND CONNECTIONS IN SENSOR COLOR FUNCTION Gray Connects to o

Summary of the content on the page No. 5

MODEL 140,141, and 142 sensors WIRING FIGURE 9. Model Xmt-C-11 Wiring (Pipe or Wall) FIGURE 8. Model Xmt-C-10 Wiring (Panel) TB2 TB1 RTN WHITE RCV B SENSE WHITE/RED RCV A RTD IN RED CLEAR RSHLD SHLD DRVB CLEAR GRAY ORANGE DRVA CLEAR DSHLD FIGURE 10. Model 1066 Wiring FIGURE 11. Model 5081C Wiring FIGURE 12. Model 6081-C Wiring 5

Summary of the content on the page No. 6

MODEL 140,141, and 142 sensors WIRING RETRACTING AND INSERTING THE MODEL 140 SENSOR CAUTION Model 140 sensors are retractable. BEFORE RETRACTING THE SENSOR, be absolutely certain the process pressure is less than 100 psig (791 kPa abs) and the process temperature is at a safe level! RETRACTING THE SENSOR 1. Push in on the sensor junction box and slowly loosen the sensor compression fitting nut by reversing the sensor tightening procedure illustrated in Figure 2. 2. When the sensor com

Summary of the content on the page No. 7

MODEL 140,141, and 142 sensors WIRING 3. Slowly open the valve. WARNING Stand clear of the sensor. 4. Insert the sensor up to the desired insertion depth and turn the sensor compression fitting nut until it is finger tight. 5. Position the entire sensor for easy access to the ball valve handle, sensor compression fitting nut and J-box terminal block. 6. Tighten sensor compression fitting nut. CAUTION allation of the sensor, tighten the com- ter finger tight. If it is a reinstallation, tional tu

Summary of the content on the page No. 8

MODEL 140,141, and 142 sensors CALIBRATION CALIBRATION Model 140 sensors are not calibrated at the factory. The cell constant on the label is a nominal value only. The true cell constant can differ from the nominal value by as much as ±5%. For improved accuracy, calibrate the sensor using either a solution of known conductivity or a referee meter and sensor. If using a standard solution, choose one having conductivity in the recommended operating range for the sensor cell constant. Refer to the

Summary of the content on the page No. 9

MODEL 140,141, and 142 sensors MAINTENANCE MAINTENANCE CLEANING THE SENSOR Use a warm detergent solution and a soft brush or pipe cleaner to remove oil and scale. Isopropyl alcohol can also be used to remove oily films. Avoid using strong mineral acids to clean conductivity sensors. CHECKING MODEL 140 RETRACTION RESTRAINT The integrity of the Model 140 will become compromised is the flared tip of the electrode is allowed to blow out against the compression fitting body. In the even a blowout occ

Summary of the content on the page No. 10

MODEL 140,141, and 142 sensors ACCESSORIES REPLACEMENT PARTS PN Description 23724-00 Ball valve kit for Model 140 sensor 23730-00 Process compression fitting kit (3/4-inch NPT) for Model 140 sensor 23731-00 Process fitting rebuild kit for Model 140 sensor (includes ferrule, split ring, O-ring, lubricant) 9310120 Junction box compression fitting for Model 140 sensor 9550200 O-ring, 2-116, Viton for Model 140 sensor 3001882 Process compression fitting (3/4-inch NPT) for Model 142 sensor Junction

Summary of the content on the page No. 11

MODEL 140,141, and 142 sensors TROUBLESHOOTING TROUBLESHOOTING PROBLEM PROBABLE CAUSE SOLUTION Off-scale reading Wiring is wrong. Verify wiring. Check temperature element for open or Temperature element is open or shorted. short circuits. See Figure 14. Be sure the sensor is completely submerged Sensor is not in the process stream. in the process stream. Sensor has failed. Perform isolation checks. See Figure 15. Noisy reading Sensor is improperly installed in the Be sure sensor is completely

Summary of the content on the page No. 12

The right people, the right answers, right now. ON-LINE ORDERING NOW AVAILABLE ON OUR WEB SITE http://www.raihome.com Specifications subject to change without notice. Credit Cards for U.S. Purchases Only. Emerson Process Management 2400 Barranca Parkway Irvine, CA 92606 USA Tel: (949) 757-8500 Fax: (949) 474-7250 http://www.raihome.com © Rosemount Analytical Inc. 2010 8


Alternative user manuals
# User manual Category Download
1 Emerson 142 User manual Stud Sensor 1
2 Emerson 396R User manual Stud Sensor 3
3 Emerson 396RVP User manual Stud Sensor 1
4 Emerson 228 User manual Stud Sensor 4
5 Emerson 396VP User manual Stud Sensor 0
6 Emerson 141 User manual Stud Sensor 0
7 Emerson 396 User manual Stud Sensor 0
8 Emerson 397 User manual Stud Sensor 0
9 Emerson 398 User manual Stud Sensor 0
10 Emerson CMF200A User manual Stud Sensor 25
11 Emerson 399VP User manual Stud Sensor 3
12 Emerson 398VP User manual Stud Sensor 0
13 Emerson 400 User manual Stud Sensor 6
14 Emerson 400 VP User manual Stud Sensor 4
15 Emerson Combination pH/ORP Sensor User manual Stud Sensor 0
16 A&D sf/sg User manual Stud Sensor 2
17 Sony ICX423AL User manual Stud Sensor 1
18 Sony E01X23A41 User manual Stud Sensor 1
19 Sony ICX418ALB User manual Stud Sensor 1
20 Agilent Technologies 81680A User manual Stud Sensor 3