Omega Engineering Series Micro Flow Sensor FP-5060 user manual

User manual for the device Omega Engineering Series Micro Flow Sensor FP-5060

Device: Omega Engineering Series Micro Flow Sensor FP-5060
Category: Stud Sensor
Manufacturer: Omega Engineering
Size: 0.39 MB
Added : 6/25/2014
Number of pages: 8
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega Engineering Series Micro Flow Sensor FP-5060. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega Engineering Series Micro Flow Sensor FP-5060.

For your convenience

If looking through the Omega Engineering Series Micro Flow Sensor FP-5060 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega Engineering Series Micro Flow Sensor FP-5060 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega Engineering Series Micro Flow Sensor FP-5060 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega Engineering Series Micro Flow Sensor FP-5060 User manual - Online PDF
Advertisement
« Page 1 of 8 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega Engineering Series Micro Flow Sensor FP-5060 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega Engineering Series Micro Flow Sensor FP-5060. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

User’s Guide
Shop online at
www.omega.com
e-mail: info@omega.com
FP-5060
Series Micro-Flow Sensors

Summary of the content on the page No. 2

® OMEGAnet Online Service Internet e-mail www.omega.com info@omega.com Servicing North America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certifi ed Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Berg

Summary of the content on the page No. 3

OMEGA FP-5060 Series Micro-Flow Sensors SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi cations. 3. Do not install/service without following installation instructions (see sensor manual). 4. Wear safety goggles and faceshield during installation/service. 5. Do not alter product construction. 6. Failure to follow safety instructions could result in severe personal injury! 1. Instrument Wiring OMEGA FP-90 Series, FPM-5500, FPM-9020A

Summary of the content on the page No. 4

3. Surface Mount Instructions Remove sensor then use correct 2 screws for panel material. #6 or M3 metric screws recommended 120° 1 Mounting surface (top), Mounting surface (side) Mounting surface 68 mm (2.68 in.) bolt circle 4. Fitting Installation CAUTION: • Maximum pipe fi tting torque: 10 ft - lbs (13 N m). • DO NOT overtighten. Failure to observe torque specifi cation may permanently damage sensor ports. FP-5060 Pipe Pipe fitting Pipe fitting Pipe Sealant Technical Notes: • Compatible

Summary of the content on the page No. 5

6. Specifi cations General Electrical Flow range: Supply voltage: 5 to 24 VDC, regulated 5061 and 5062: 0.11 to 2.6 lpm (0.03 to 0.7 gpm) Supply current: 10 mA max. 5063 and 5064: 1.13 to 12.11 lpm (0.3 to 3.2 gpm) Output type: Open-collector NPN transistor, 10 mA max sink Linearity: ±1.2% of full range Repeatability: ±0.5% of full range Connections: ¼ in. NPT (male) or ISO 7/1 - R¼ (male) Quality Standard Cable length: 8 m (25 ft.), can splice up to 300 m (1000 ft.) max. • Manufactured u

Summary of the content on the page No. 6

NOTES: page 6 OMEGA FP-5060 Series Micro Flow Sensor

Summary of the content on the page No. 7

WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from date of purchase. OMEGA’s WARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time. This ensures that OMEGA’s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA’s Customer Service Departme

Summary of the content on the page No. 8

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course! Shop online at www.omega.com TEMPERATURE  Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies  Wire: Thermocouple, RTD & Thermistor  Calibrators & Ice Point References  Recorders, Controllers & Process Monitors  Infrared Pyrometers PRESSURE, STRAIN AND FORCE  Transducers & Strain Gages  Load Cells & Pressure Gages  Displacement Transducers  Instrumentation & Accessori


Alternative user manuals
# User manual Category Download
1 Omega Engineering CDE681 User manual Stud Sensor 0
2 Omega Engineering CDE-45P User manual Stud Sensor 1
3 Omega Engineering OS136 User manual Stud Sensor 4
4 Omega Engineering ULTRASONIC SENSOR LVU30 User manual Stud Sensor 2
5 Omega Engineering LVRD500 User manual Stud Sensor 8
6 Omega Engineering FLR1000 User manual Stud Sensor 4
7 Omega Engineering LVU40 User manual Stud Sensor 1
8 Omega Engineering Wet/Wet Differential Sensor PX838 User manual Stud Sensor 0
9 Omega Engineering LV860 User manual Stud Sensor 0
10 A&D sf/sg User manual Stud Sensor 2
11 Sony ICX423AL User manual Stud Sensor 1
12 Sony E01X23A41 User manual Stud Sensor 1
13 Sony ICX418ALB User manual Stud Sensor 1
14 Agilent Technologies 81680A User manual Stud Sensor 3
15 Agilent Technologies 81689A User manual Stud Sensor 3