Robertshaw 158A user manual

User manual for the device Robertshaw 158A

Device: Robertshaw 158A
Category: Stud Sensor
Manufacturer: Robertshaw
Size: 0.69 MB
Added : 2/4/2014
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Robertshaw 158A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Robertshaw 158A.

For your convenience

If looking through the Robertshaw 158A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Robertshaw 158A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Robertshaw 158A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Robertshaw 158A User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Robertshaw 158A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Robertshaw 158A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MODEL 158A 909GF197B




INSTRUCTION MANUAL


FOR

MODEL 158A

LEVEL-TEL



We do our level best



















Probe, Cable and Conduit Outlet Box
shown for illustration only.

Must be ordered separately.







INSTRUCTION MANUAL NUMBER



Industrial Products Division
909GF197B
1602 Mustang Drive

Maryville, Tennessee 37801
P-2410
Phone: (865) 981-3100 Fax: (865) 981-3168

- 1 -

Summary of the content on the page No. 2

MODEL 158A 909GF197B Table 3 – DISPLAY HOUSING AND Section I – DESCRIPTION INDICATION Desig. Description 1.1 GENERAL A Water tight enclosure without The Robertshaw Model 158A Level-Tel is a indicator. capacitance operated DC current transmitter with Meets NEMA Type 4 and CSA noninteracting and independent zero and span Enclosure 5. adjustments internally located. The transmitter is B Water tight housing with indicator. remotely mounted from the probe with a triax Meets NEM

Summary of the content on the page No. 3

MODEL 158A 909GF197B 1.3 TRIAXIAL CABLE ACCESSORY ITEMS 032KE03X-XX 032KE090-05 (5 ft long) GENERAL PURPOSE (polyethylene insulated) 032KE090-10 (10 ft long) Triax Cable with probe connection conduit GENERAL PURPOSE (polyethylene insulated) outlet box. (Recommended for use with Triax Cable in explosion proof flexible conduit customer supplied rigid or flexible conduit.) (protective armor) with seal fitting and probe connection conduit outlet box. Maximum

Summary of the content on the page No. 4

MODEL 158A 909GF197B 2.4 ENCLOSURE Section II - SPECIFICATIONS Water Tight ............... NEMA 4, CSA Enclosure 5, 2.1 ENVIRONMENTAL Polyurethane painted cast aluminum Ambient Temperature Limits.......-40 ° F to +160 ° F Explosion Proof...Class I, Division 1, Groups C, D; Class II, Division 1, Groups E, F, G; Vibration Limits ................ ± 2 G from 10 to 200 Hz Polyurethane painted cast aluminum 2.2 ELECTRICAL Weatherproof ..... NEMA 12, 13, CSA Enclosure 3, Polyuretha

Summary of the content on the page No. 5

MODEL 158A 909GF197B 3.3 TRANSMITTER UNIT MOUNTING Section III - INSTALLATION The Model 158A is designed for vertical surface 3.1 GENERAL mounting: e.g. wall, panel or column. Choose the mounting location to avoid extremes of ambient Examine the instrument for possible shipping temperature or vibration (see Specifications, damages. IMPORTANT: If for any reason it is Section II). determined that parts should be returned to the factory, please notify the nearest Robertshaw 3

Summary of the content on the page No. 6

MODEL 158A 909GF197B MM INCHES SEE FIGURE 5 FOR DIMENSIONS OF PROBE MOUNTED CONDUIT OUTLET BOX. FIGURE 1 MOUNTING DIMENSIONS FOR MODEL 158A WATER TIGHT ENCLOSURE WITH AND WITHOUT INDICATOR, MODELS 158A – ( ) ( ) – A1 AND 158A – ( ) ( ) B1. - 6 -

Summary of the content on the page No. 7

MODEL 158A 909GF197B MM INCHES SEE FIGURE 5 FOR DIMENSIONS OF PROBE MOUNTED CONDUIT OUTLET BOX. FIGURE 2 MOUNTING DIMENSIONS FOR MODEL 158A EXPLOSION PROOF ENCLOSURE WITH AND WITHOUT INDICATOR, MODELS 158A – ( ) ( ) – C1 AND 158A – ( ) ( ) – D1. - 7 -

Summary of the content on the page No. 8

MODEL 158A 909GF197B TERMINAL TERMINAL CONNECTION REMARKS PROBE TRIAX WHITE LEAD SHLD TRIAX RED LEAD GND TRIAX BLACK LEAD 1 N ( ) SUPPLY SEE RATING PLATE 2 H (+) SUPPLY (120 VAC, 240 VAC OR 26.5 VDC) GND CHASSIS GROUND 3 ( ) OUTPUT SIGNAL SEE NOTE 1 4 (+) OUTPUT SIGNAL NOTES: 1. REMOVE JUMPER ACROSS OUTPUT TERMINALS 3 AND 4 WHEN RECORDE

Summary of the content on the page No. 9

MODEL 158A 909GF197B MILLIMETER INCH SEE FIGURE 5 FOR DIMENSIONS OF PROBE MOUNTED CONDUIT OUTLET BOX. FIGURE 4 MOUNTING DIMENSIONS FOR LARGE WEATHERPROOF ENCLOSURE WITH INDICATOR (USED WITH OPTIONAL ALARMS) MODEL 158A – ( ) ( ) – E ( ). - 9 -

Summary of the content on the page No. 10

MODEL 158A 909GF197B FIGURE 5 DIMENSIONS OF PROBE MOUNTED CONDUIT OUTLET BOX SUPPLIED WITH TRIAX CABLE. (TRIAX CABLE ORDERE D SEPARATELY) FIGURE 6 ELECTRICAL CONNECTIONS FOR LARGE WEATHERPROOF ENCLOSURE, MODEL 158A – ( ) ( ) – E ( ). - 10 -

Summary of the content on the page No. 11

MODEL 158A 909GF197B FIELD WIRING TERMINAL CONNECTION REMARKS PROBE TRIAX WHITE LEAD TB2 SHLD TRIAX RED LEAD GND TRIAX BLACK LEAD G CHASSIS GROUND 1 N ( ) SUPPLY SEE RATING PLATE (120 VAC, 240 VAC OR 26.5 VDC) 2 H (+) SUPPLY TB7 3 ( ) OUTPUT SEE NOTES 2 AND 5 4 (+) OUTPUT 5 6 NO CONNECTION SEE NOTE 5 7 8 9 N.C. 10 COM. TB8 OPTIONAL NO. 1 ALARM CONTACTS 11 N.O. 12 N.C. SEE NOTES 1 AND 3 13 COM. 14

Summary of the content on the page No. 12

MODEL 158A 909GF197B NOTES: 1. IN FIGURE 1, THE TRANSMITTER IS CSA CERTIFIED FOR HAZARDOUS LOCATIONS, CLASS I, DIVISION 1, GROUPS C & D; CLASS II, DIVISION 1, GROUPS E, F & G. THE PROBE IS INTRINSICALLY SAFE FOR CLASS I, DIVISION 1, GROUPS A, B, C & D; CLASS II, DIVISION 1, GROUPS E, F & G. IN FIGURE 2, THE TRANSMITTER IS CSA CERTIFIED FOR ENCLOSURE 5. THE PROBE IS INTRINSICALLY SAFE FOR C

Summary of the content on the page No. 13

MODEL 158A 909GF197B Alarm Module No. 2. Refer to Figure 9 and the Section IV – OPERATION following paragraphs for detailed instructions on how to change the links to obtain the desired 4.1 CALIBRATION ADJUSTMENTS mode. The supply voltage to the instrument All the adjustments for calibrating the Model 158A should be disconnected when making this Level-Tel are located on the printed circuit board change. assembly and consist of the following (see Figure 8): 4.2.1 Low Level

Summary of the content on the page No. 14

MODEL 158A 909GF197B CALIBRATION PROCEDURE d) Change the process level in the tank to the desired 100% (high) level and adjust the 4.3.1 Zero and Span Calibration Coarse and Fine Span until the output or With the Model 158A Level-Tel mounted and meter indicates 100% (5, 10, 20 or 50 mA electrical connections made, the following depending on the output signal range of the procedures should be followed in calibrating the Model 158A Level-Tel being used). instrument: Clockwise rota

Summary of the content on the page No. 15

MODEL 158A 909GF197B Section IV – SPARE PARTS SPARE PARTS DESIG. DESCRIPTION SUPPLY OUTPUT USED ON PART NO. 1-5 mADC 158A-A1-XX 044KB766-01 26.5 VDC 4-20 mADC 158A-B1-XX 044KB766-04 10-50 mADC 158A-C1-XX 044KB766-07 0-10 mADC 158A-D1-XX 044KB766-10 1-5 mADC 158A-A2-XX 044KB766-02 TB2 TRANSMITTER 4-20 mADC 158A-B2-XX 044KB766-05 120 VAC PRINTED CIRCUIT ASSY 50/60 Hz 10-50 mADC 158A-C2-XX 044KB766-08 0-10 mADC

Summary of the content on the page No. 16

MODEL 158A 909GF197B Q-3882 (1/03) Printed in U.S.A. - 16 -


Alternative user manuals
# User manual Category Download
1 A&D sf/sg User manual Stud Sensor 2
2 Sony ICX423AL User manual Stud Sensor 1
3 Sony E01X23A41 User manual Stud Sensor 1
4 Sony ICX418ALB User manual Stud Sensor 1
5 Agilent Technologies 81680A User manual Stud Sensor 3
6 Agilent Technologies 81689A User manual Stud Sensor 3
7 Agilent Technologies 81480A User manual Stud Sensor 1
8 Agilent Technologies 85037-90013 User manual Stud Sensor 2
9 Agilent Technologies 81682A User manual Stud Sensor 2
10 Agilent Technologies 81640A User manual Stud Sensor 1
11 Agilent Technologies 4A User manual Stud Sensor 1
12 Agilent Technologies E9300 User manual Stud Sensor 1
13 Agilent Technologies 3A User manual Stud Sensor 1
14 Agilent Technologies 81632A User manual Stud Sensor 10
15 Agilent Technologies 81642A User manual Stud Sensor 1