Emerson FDESIGN 30004000A user manual

User manual for the device Emerson FDESIGN 30004000A

Device: Emerson FDESIGN 30004000A
Category: Switch
Manufacturer: Emerson
Size: 2.79 MB
Added : 1/15/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Emerson FDESIGN 30004000A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Emerson FDESIGN 30004000A.

For your convenience

If looking through the Emerson FDESIGN 30004000A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Emerson FDESIGN 30004000A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Emerson FDESIGN 30004000A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Emerson FDESIGN 30004000A User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Emerson FDESIGN 30004000A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Emerson FDESIGN 30004000A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

7000 Series ADTS
Operator’s
Automatic Delayed–Transition Transfer Switches
Manual
E–design 150–400A, F–design 600–800A,
G–design 1000–4000A, F–design 3000–4000A,
TABLE OF CONTENTS
DANGER is used in this manual to warn of high
section-page
voltages capable of causing shock, burns, or death.
INSTALLATION ........................ 1-1
Mounting and Line Connections ......... 1-1
Auxiliary Circuits and Harness........... 1-2
WARNINGisusedinthismanualtowarn
Engine Starting Contacts ............... 1-2

Summary of the content on the page No. 2

Catalog Number Identification Typical7000Seriescatalogno.forG–designswitchedneutral,3pole,2000A,480V,ADTSinType1enclosure: G 7ADTS B 3 2000 N 5 C design prefix letter Neutral PhasePoles Amperes Voltage Controller Enclosure A–solid 2–singleØ 5–standard 150 1000 A 115 J 400 C –type1 260 B–switched 3–threeØ 1200 B 120 5X–if F–type3R K 415 accessories 400 G–type4 C 208 L 440 1600 ordered 600 L–type12 2000 blank–none D 220 M 460 800 M –type3Rsecure 3000 E 230 N 480 N –type4secure F 240 P 550 4000 P –

Summary of the content on the page No. 3

Rating Label Nameplate The Transfer Switch nameplate includes data for each Eachautomaticdelayed–transitiontransferswitchcontainsa specific7000SeriesADTS. Use the switchonly withinthe rating label to define the loads and fault circuit withstand / limitsshownonthisnameplate.AtypicalCatalogNumber closing ratings. Refer to the label on the transfer switch for isshownonthepreviouspagewithitselementsexplained. specificvalues. Do not exceed the values on the rating label. Exceeding the rating can caus

Summary of the content on the page No. 4

SECTION1 INSTALLATION ASCOSeries7000AutomaticDelayed–Transition TransferSwitchesarefactorywiredandtested. Field installationsimplyrequiresmountingandconnectionof De–energizetheconductorsbeforemakingany line or auxiliary circuitry connections. Be sure servicecables, andauxiliarycontrolcircuits(ifrequired). that Normal and Emergency line connections Remove the Shipping Skid areinproperphaserotation.Placeenginegen- eratorstartingcontrolintheOFFposition.Make Forlargeswitches, openthefrontdoorandremo

Summary of the content on the page No. 5

INSTALLATION (continued) TightenboltedjointstothetorquespecifiedinTableA. Engine Starting Contacts Theenginecontrolcontact connections(ifused)are locatedonthe transferswitch. Connect signalwiresto appropriateterminalsasspecifiedinTableBandshown The reliablility of the connection depends in Figure 1---1. onhowcleanandhowtightthejointis. Table B. Engine start connections Table A. Tightening torque values for bolted joints Whennormal Terminals on (Grade 5 hardware) source fails transferswitch conta

Summary of the content on the page No. 6

INSTALLATION (continued) handle shafts handle handle Figure 1-2. Figure 1-3. Figure 1-4 150 – 400 A (3 pole) 600 & 800 A (& 4 pole 400 A) 3000 & 4000 A E–design switches F–design switches F–design transfer switches 1000through 4000AG–design SeeFigure1-5. 1–ManualOperation Installthe hub(with pin) onto the shaft and insert the Adetachablemanualoperatorhandleisprovidedonthe manualfirmlyintothesideholeinthehub. Pushinor Transfer Switchesformaintenancepurposesonly.Manual pullout hubto engage opposit

Summary of the content on the page No. 7

INSTALLATION (continued) GREEN RED observe these lights GREEN RED AMBER Figure 1-6. Standard controls and indicators. Close the normal source circuit breaker. The Transfer Switch 2–VoltageChecks 1 Connected To Normal and the Load Disconnect First checknameplateontransferswitch;ratedvoltage Normal Source Accepted lights Active should come on. mustbethesameasnormalandemergencylinevoltages. Use an accurate voltmeter to check phase to phase and Before energizing the switchcheckto be 2 phase to neutr

Summary of the content on the page No. 8

INSTALLATION (continued) GREEN RED operate observe this switch these lights GREEN RED AMBER Figure 1-7. Standard controls and indicators. Turn and hold Transfer Control switch clockwise to Transfer 3 --- ElectricalOperation Test until the engine starts 1 and runs (within 15 sec.). The Load Thisprocedure willcheck the electricaloperationof the Disconnect Active Emergency Source Accepted AutomaticDelayed–TransitionTransferSwitch. See light should come on. Figure 1---7. Transfer switch CN opens and

Summary of the content on the page No. 9

SECTION2 TESTING&SERVICE TRANSFER TEST DISCONNECTING THECONTROLLER Operate the 7000 Series ADTS at least once a month The harness disconnect plugs are furnished forrepair by followingthe five–step Electrical Operation purposesonly and should not have to be unplugged. Transfer Testprocedure on page 1–5. If the controlpanelmust be isolated, followthese steps: Disconnecting the Plugs PREVENTIVEMAINTENANCE Reasonable care inpreventive maintenance willinsure high reliability and longlife forthe 7000

Summary of the content on the page No. 10

TESTING&SERVICE (continued) 2. Use manualhandle to manually operate transfer MANUALLOADTRANSFER switch to the opposite source. First open the Thisprocedure willmanually transferthe loadif the closedtransferswitch, thenclose the othertransfer controlpanelis disconnected. switch. 3. Thenremovethemaintenancehandle. Seepage1–3. Do notmanually operate the transferswitch until bothpowersources are disconnected (all conductors deenergized). Verify thatthemaintenancehandle has beenremoved before proceed

Summary of the content on the page No. 11

Summary of the content on the page No. 12

INDEX A I O operation auxiliarycablebox,1–1 electrical,1–5 inspection, 3–1 manual, 1–3 auxiliarycircuits,1–2 illustrationof, 1–3 installation, 1–1 warning, 1–3 sequenceof, 2–1 B optionalaccessories barriers, 1–1 see ControllerUser’s Guide L P labels, C parts, 2–1 enginestartcontacts, 1–2 phaserotationcheck,1–4 cable rating, cover problem, 2–2 lugs, 1–2 preparation,1–2 lights, 1–4, 1–5 R catalognumber, cover ratinglabel, cover cleaning, 2–1 LoadDisconnect Activelight, 1–5 replacementparts,2–1 con


Alternative user manuals
# User manual Category Download
1 Emerson 5081-T User manual Switch 38
2 Emerson ASCO 300 Series User manual Switch 747
3 Emerson ASCO 7000 User manual Switch 91
4 Emerson 7000 User manual Switch 58
5 Emerson ASCO 185 User manual Switch 45
6 Emerson 7ADTB User manual Switch 3
7 Emerson 185 User manual Switch 7
8 Emerson B-294 HD User manual Switch 0
9 Emerson Autochangeover Controllers AC8 User manual Switch 7
10 Emerson 214A401 User manual Switch 0
11 Emerson 214A400 User manual Switch 3
12 Emerson 214A404 User manual Switch 0
13 Emerson 260 User manual Switch 0
14 Emerson 300 User manual Switch 1
15 Emerson 386 User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4