Honeywell R482J user manual

User manual for the device Honeywell R482J

Device: Honeywell R482J
Category: Switch
Manufacturer: Honeywell
Size: 0.14 MB
Added : 5/1/2013
Number of pages: 6
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Honeywell R482J. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Honeywell R482J.

For your convenience

If looking through the Honeywell R482J user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Honeywell R482J on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Honeywell R482J to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Honeywell R482J User manual - Online PDF
Advertisement
« Page 1 of 6 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Honeywell R482J but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Honeywell R482J. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

R182J, R482J, R845A, R847A,
R882J, RA89A, RA832A
Switching Relays
These relays provide intermediate or heavy
duty service in a wide variety of switching con-
figurations.
n Relays with 24V control coils: Rl82J, R882J, R847A, n Heavy duty relays: R847J.
RA89A, RA832A, and R845A.
n R847A has flexible internal leads to provide either
n Relays with line voltage control coils: R482J. spst or spdt switching.
n Relays with internal 24V transformer: R182J, n RA832A has contacts for low voltage and
®
RA8

Summary of the content on the page No. 2

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A SPECIFICATIONS • ORDERING INFORMATION Specifications IMPORTANT: The specifications given in this publica- replacement value. TRADELINE model specifications are tion do not include normal manufacturing toler- the same as those of standard models except as noted below. ances. Therefore, this unit may not exactly match the listed specifications Also, this product is tested and TRADELINE MODELS AVAILABLE: calibrated under closely controlled conditions

Summary of the content on the page No. 3

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A SPECIFICATIONS • INSTALLATION a IMPORTANT: The transformer on the R182 can over- heat when used with a series 20 thermostat if the total resistance of the thermostat (including thermo- Fig. 1—Approximate mounting dimensions in in. [mm]. stat wire and thermostat contact resistance) exceeds 2.5 ohms, add a 100 ohm, 10 watt resistor between 1 the W and R terminals. Table 2 gives maximum 4 [108] 4 5 thermostat wire runs; if longer runs are necess

Summary of the content on the page No. 4

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A INSTALLATION MOUNTING TABLE 3—WIRE LENGTH SPECIFICATIONS. For replacement, mount the relay in the same location as Length of Run to the old control. If this is a new installation, locate the relay Total Wire Thermostat AWG Wire vertically on a solid wall or partition as near as possible to Length (2 wires) Size the device to be controlled. Select a location that is easily (Number) accessible for installation and service. Feet Metres Feet Metres

Summary of the content on the page No. 5

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A INSTALLATION Fig. 5—Thermostat connections for R182J. Fig. 7—Schematic diagram showing R845A in multizone, forced hydronic heating system. This arrangement is suitable for any number THREE-WIRE THREE-WIRE TWO-WIRE LOW VOLTAGE LOW VOLTAGE LOW VOLTAGE of additional zones. (SERIES 10) (SERIES 20) (SERIES 80) 2 1 THERMOSTAT THERMOSTAT THERMOSTAT HYDRONIC HEATING TO ADDITIONAL R845A CONTROL TERMINALS RELAYS FOR OTHER ZONES W R B B W R T RA845A RELAY T

Summary of the content on the page No. 6

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A INSTALLATION • SERVICE AND CHECKOUT Fig. 9—Internal schematic and hookup for Fig. 11—Internal view of RA832A Switching R847A. Relay. LOW VOLTAGE (CLASS 2) 2-WIRE THERMOSTAT T X R847A TT RELAY T X L2 L1 4 3 7 6 24V TRANSFORMER 4 4 3 1 1 2 1 TO TO L1 LOAD 2 L2 POWER LOAD 1 POWER (HOT) 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 1 2 WHEN CONTROLLING TWO LOADS, USE 3 AND 4 FOR LINE VOLTAGE LOAD AND 5 AND 6 FOR L


Alternative user manuals
# User manual Category Download
1 Honeywell AML54 Series User manual Switch 1
2 Honeywell AML56 Series User manual Switch 1
3 Honeywell 7800 User manual Switch 62
4 Honeywell CSP-C User manual Switch 0
5 Honeywell CSP-O User manual Switch 0
6 Honeywell CSS-O User manual Switch 2
7 Honeywell C645A-E User manual Switch 4
8 Honeywell FAST-ACTING, TWO-POSITION ACTUATORS ML4702 User manual Switch 0
9 Honeywell EVN2000 Series User manual Switch 2
10 Honeywell FAST-ACTING, TWO-POSITION ACTUATORS ML4302 User manual Switch 0
11 Honeywell FAST-ACTING, TWO-POSITION ACTUATORS ML4202 User manual Switch 0
12 Honeywell CSS-C User manual Switch 0
13 Honeywell FAST-ACTING, TWO-POSITION ACTUATORS ML4802 User manual Switch 0
14 Honeywell FAST-ACTING, TWO-POSITION ACTUATORS ML8202 User manual Switch 1
15 Honeywell FF-SNC User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4