Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111 user manual

User manual for the device Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111

Device: Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111
Category: Switch
Manufacturer: Multi-Tech Systems
Size: 0.72 MB
Added : 11/5/2014
Number of pages: 99
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111.

For your convenience

If looking through the Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111 User manual - Online PDF
Advertisement
« Page 1 of 99 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Multi-Tech Systems Multi-Tech MultiFRAD 100-Series FR111. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Model FR111
Single Port Frame Relay
Access Device with 56K DSU
Owner's Manual

Summary of the content on the page No. 2

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there

Summary of the content on the page No. 3

Summary of the content on the page No. 4

Owner's Manual 82067401 Revision B TM MultiFRAD 100-Series (Model No FR111) This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved. Copyright © 1998, by Multi-Tech Systems, Inc. Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore,

Summary of the content on the page No. 5

Contents Chapter 1 - Introduction and Description 1.1 Introduction ................................................................................. 9 1.2 About This Manual ................................................................... 10 1.3 A Typical Application ............................................................... 12 1.4 FCC Regulations for Telephone Line Interconnection........... 16 1.5 Canadian Limitations Notice ...................................................18 1.6 Spec

Summary of the content on the page No. 6

5.3 Data Port Configuration ........................................................... 56 5.4 Trunk Configuration .................................................................62 5.5 Statistics....................................................................................66 5.6 Diagnostics...............................................................................66 Chapter 6 - ASCII Terminal Menu System 6.1 Introduction ...............................................................

Summary of the content on the page No. 7

1 Introduction and Description

Summary of the content on the page No. 8

8

Summary of the content on the page No. 9

1.1 Introduction The Multi-Tech Systems MultiFRAD™ 100-Series, Model number FR111, is a one-port Frame Relay Access Device (FRAD) with 56K DSU that encapsulates non-packetized data from a serial device into frame relay frames and is responsible for framing that data with header and trailer information prior to transmission to a frame relay network. The Multi- FRAD allows a non-frame relay device to connect to a common carrier frame relay network service or private frame relay network. The acce

Summary of the content on the page No. 10

1.2 About This Manual This manual describes the MultiFRAD, and tells you how to install and configure the unit. The information contained in each chapter is as follows: Chapter 1 - Introduction and Description Chapter 1 introduces the MultiFRAD 100-Series. A typical application is presented with a discussion on ordering a frame relay line and how to configure a MultiFRAD. A list of relevant specifications are provided at the end of the chapter. Chapter 2 - Front and Back Panel Descriptions Ch

Summary of the content on the page No. 11

Chapter 6 - ASCII Terminal Menu System Chapter 6 provides a description of the ASCII terminal menu system. The ASCII terminal menu system is used when a dumb terminal is connected to the data port. These menus allow you to configure the data port and trunk, view statistics, reset the unit, and enable diagnos- tics. Chapter 7 - Service, Warranty and Tech Support Chapter 5 provides instructions on getting service for your MultiFRAD at the factory, a statement of the limited warranty, information

Summary of the content on the page No. 12

1.3 A Typical Application A typical application for a MultiFRAD 100-Series is connecting a single non-frame relay device to a frame relay network. The MultiFRAD 100- Series is usually used at a remote site where a single DLCI and a single device needs to be connected to a frame relay network. A MultiFRAD 100-Series can connect any existing synchronous or asynchronous non-frame relay device to a frame relay network. MultiMux Trunk Data LAN 1 R BUFFER F L R T A INTERNAL LINK DEVICE N A

Summary of the content on the page No. 13

your capability to present data to the local telephone switch. Your capability to present data is determined by the internal DSU (Data Service Unit) that can transfer digital data at a maximum rate of 56,000 bits-per-second to the network. A general rule of thumb in this scenario is to assign a CIR of 32K bps and an excess burst rate (Be) of 24K bps. The sum of the CIR and Be can not exceed your capability to present data to the network. Finally during subscription, the management type is def

Summary of the content on the page No. 14

length, parity, stop bits, and flow control. The Async Data Port Configu- ration dialog box displays the default parameters that may apply to a majority async devices. When the data device is defined, then the trunk configuration needs to be defined. The trunk configuration is displayed in the Trunk Configura- tion dialog box. Most of the trunk information is supplied by your network service provider. For example, if the MultiFRAD at remote site 2 in our typical Frame Relay network in Figure

Summary of the content on the page No. 15

tion. The trunk configuration would be complete by clicking on the Save button and returning to the Main menu. In the Main menu, click on the download button to transfer the configuration to the MultiFRAD. Within a few seconds the new configuration is downloaded to the MultiFRAD and it is ready for operation. 15

Summary of the content on the page No. 16

1.4 FCC Regulations for Telephone Line Intercon- nection 1. This equipment complies with Part 68 of the FCC rules. On the outside surface of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN). If requested, this information must be provided to the telephone company. 2. As indicated below the suitable jack (USOC connecting arrange- ment) for this equipment is shown. If applicable, the facility interface codes (FIC)

Summary of the content on the page No. 17

commission or corporation commission for information.) 9. If so required, this equipment is hearing aid compatible. Manufacturer: Multi-Tech Systems, Inc. Model Number: MultiFRAD 100-Series FCC Registration Number: AU7USA-24704-XD-N Ringer Equivalence: N/A Modular Jack (USOC) RJ48 Service Center in U.S.A. Multi-Tech Systems Inc. 2205 Woodale Drive Mounds View, MN 55112 USA (612) 785-3500 or (800) 328-9717 U.S. Fax (612) 785-9874 17

Summary of the content on the page No. 18

1.5 Canadian Limitations Notice Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination of a interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5. Notice: The Industry Canada label identifies certificated equipment. This certification mean

Summary of the content on the page No. 19

1.6 Specifications Data Port • Single data port with synchronous or asynchronous data format • Async data rate up to 57.6K bps or sync data rate up to 56K bps • RS232C and ITU-T V.35 interface using an adapter cable • Internal shunt plugs to configure RS232C or ITU-T V.35 interface • Async data format of 5,6,7, or 8 bits; 1, 1½, or 2 stop bits; odd, even, or no parity • Sync data format is HDLC/SDLC • Data port connector is a DB-25 female Trunk • Single trunk port with synchronous DDS or compati

Summary of the content on the page No. 20

20


Alternative user manuals
# User manual Category Download
1 Multi-Tech Systems Hub User manual Switch 0
2 Multi-Tech Systems MultiVOIP GSM SIP-to-Cellular Gateways MVPGSM-2 User manual Switch 0
3 Sony 4-296-436-11 (2) User manual Switch 0
4 3Com 10/100BASE-TX User manual Switch 61
5 3Com 2226-SFP User manual Switch 688
6 3Com 16985ua.bk User manual Switch 10
7 3Com 10BASE-T User manual Switch 4
8 3Com 10BASE-2 User manual Switch 1
9 3Com 1000BASE User manual Switch 6
10 3Com 2226 PLUS User manual Switch 473
11 3Com 2250-SFP User manual Switch 538
12 3Com 1600 User manual Switch 0
13 3Com 2924-PWR User manual Switch 72
14 Sony BZPS-8001 User manual Switch 1
15 Sony DFS-700P User manual Switch 123