National Instruments Compact FieldPoint Mounting Accessories cFP-21xx user manual

User manual for the device National Instruments Compact FieldPoint Mounting Accessories cFP-21xx

Device: National Instruments Compact FieldPoint Mounting Accessories cFP-21xx
Category: Switch
Manufacturer: National Instruments
Size: 1.45 MB
Added : 9/15/2013
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for National Instruments Compact FieldPoint Mounting Accessories cFP-21xx. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with National Instruments Compact FieldPoint Mounting Accessories cFP-21xx.

For your convenience

If looking through the National Instruments Compact FieldPoint Mounting Accessories cFP-21xx user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual National Instruments Compact FieldPoint Mounting Accessories cFP-21xx on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual National Instruments Compact FieldPoint Mounting Accessories cFP-21xx to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
National Instruments Compact FieldPoint Mounting Accessories cFP-21xx User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual National Instruments Compact FieldPoint Mounting Accessories cFP-21xx but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to National Instruments Compact FieldPoint Mounting Accessories cFP-21xx. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Quick Start Guide

FieldPoint cFP-21xx
What You Need to Get Set Up
•cFP-21xx LabVIEW RT controller � 11–30 VDC power supply
� Mounting hardware (DIN rail, � Accessories: Ethernet cable,
panel-mount, or rack-mount number 2 Phillips screwdriver
accessory)
� PC running Windows
� I/O module(s)
� FieldPoint software 4.1.1 or later
�cFP-BP-x backplane, connector
� LabVIEW Real-Time Module
blocks, cables

Summary of the content on the page No. 2

1. Mount the Compact FieldPoint Backplane You can mount the cFP-BP-x backplane on a 35mm DIN rail, on a panel, or in a standard 19 in. rack. Before using any of these mounting methods, record the serial number from the back of the backplane. Each set of mounting instructions in this document includes an instruction to connect the protective earth (PE) ground terminal on the cFP-BP-x backplane to the system safety ground. The backplane PE ground terminal has the following symbol stamped besi

Summary of the content on the page No. 3

4 slots = 246 mm (9.68 in.) 8 slots = 441 mm (17.4 in.) Cabling Clearance Cabling Clearance Cooling Outline 51 mm (2 in.) All Around 4 slots = 246 mm (9.68 in.) 8 slots = 441 mm (17.4 in.) Cooling Outline 51 mm (2 in.) Cooling Outline 51 mm (2 in.) Caution If you are using UL Recognized I\O modules with the Compact FieldPoint system, you must install the entire system in a suitably rated, UL Listed NEMA or IP enclosure. © National Instruments Corporation 3 cFP-21xx Quick Start Guide Min. 182

Summary of the content on the page No. 4

Caution NI recommends that you use one of the mounting systems described in this document. If you decide to use a custom mounting solution, make sure that the screws you use are short enough to fit in the holes in the backplane. The screw holes are 5 mm (0.2 in.) deep. cFP-21xx Quick Start Guide 4 ni.com

Summary of the content on the page No. 5

Mounting the Backplane on a Panel 1. Fasten the panel-mount plates to the back of the cFP-BP-x using a number 2 Phillips screwdriver and the 8-32 × 5/16 in. countersink screws shipped with the kit. Caution Do not use screws longer than 5/16 in. to fasten the panel-mount plates to the backplane. 102 mm (4 in.) 457 mm (18 in.) © National Instruments Corporation 5 cFP-21xx Quick Start Guide INSTRUMENTS NATIONAL

Summary of the content on the page No. 6

104.78 mm (4.1 in.) 63.50 mm 127.00 mm (2.5 in.) (5.0 in.) 22.23 mm (0.9 in.) 440.94 mm (17.4 in.) 102 mm (4 in.) 260 mm (10.25 in.) cFP-21xx Quick Start Guide 6 ni.com 33.15 mm (1.3 in.) 129.54 mm (5.1 in.) 311.40 mm (12.3 in.) 387.60 mm (15.3 in.) 407.80 mm (16.1 in.)

Summary of the content on the page No. 7

104.74 mm (4.1 in.) 63.46 mm 127.00 mm (2.5 in.) (5.0 in.) 22.19 mm (0.9 in.) 245.87 mm (9.6 in.) 2. Bolt or screw the panel-mount accessory to a panel. 3. Connect the PE ground terminal on the cFP-BP-x to safety ground. Caution Disconnect power before removing the backplane from the panel. Mounting the Backplane on a DIN Rail NI recommends DIN rail mounting for the cFP-BP-4 only. Use panel mounting or rack mounting for the cFP-BP-8. The DIN rail mounting kit is NI part number 778614-01. 1

Summary of the content on the page No. 8

Caution Do not use screws longer than 5/16 in. to fasten the DIN rail clip to the backplane. 2. Insert one edge of the DIN rail into the deeper opening of the DIN rail clip. 3. Press down firmly on the backplane to compress the spring until the clip locks in place on the DIN rail. 4. Connect the PE ground terminal on the cFP-BP-4 to safety ground. Caution Disconnect power before removing the backplane from the DIN rail. cFP-21xx Quick Start Guide 8 ni.com IN NA TTU IO M NEN ALT S R S

Summary of the content on the page No. 9

Mounting the Backplane in a Standard 19 in. Rack 1. Fasten the rack-mount bracket to the back of the cFP-BP-x using the captive screws on the bracket. 2. Bolt the rack-mount accessory to a standard 19 in. rack. © National Instruments Corporation 9 cFP-21xx Quick Start Guide IN N SA TR TU IO M NE A N LT S

Summary of the content on the page No. 10

3. Connect the PE ground terminal on the cFP-BP-x to safety ground. Caution Disconnect power before removing the backplane from the DIN rail. cFP-21xx Quick Start Guide 10 ni.com NATIONAL INSTRUMENTS

Summary of the content on the page No. 11

NATIONAL INSTRUMENTS 2. Install the cFP-21xx Controller on the Backplane 1. Make sure that no power is connected to the controller. 2. Make sure that the cFP-21xx controller is right side up with the NI logo at the top, and align the captive screws on the controller with the holes on the backplane. 3. Seat the card edge at the back of the controller in the card-edge connector on the backplane. 4. Press the controller firmly to seat it on the backplane. 5. Using a number 2 Phillips screwdriv

Summary of the content on the page No. 12

3. Install I/O Modules on the Backplane 1. Align the captive screws on the I/O module with the holes on the backplane. 2. Press firmly to seat the I/O module on the backplane. 3. Using a number 2 Phillips screwdriver with a shank of at least 64 mm (2.5 in.) length, tighten the captive screws to 1.1 N · m (10 lb · in.) of torque. 4. Repeat this procedure to install additional I/O modules on the backplane. cFP-21xx Quick Start Guide 12 ni.com

Summary of the content on the page No. 13

4. Install Connector Blocks on the Backplane In order to connect I/O modules to input signals or to external loads, you need to install a cFP-CB-x connector block or other connectivity accessory for each I/O module on the backplane. Use the connector socket to the right of each I/O module socket. Caution Do not insert or remove connector blocks or other connectivity accessories while power is applied to them. 1. Wire field devices as described in the I/O module and connector block operatin

Summary of the content on the page No. 14

5. Connect the cFP-21xx to Your Network Connect the cFP-21xx controller to an Ethernet network using the RJ-45 Ethernet port on the controller. Use a standard Category 5 Ethernet cable to connect the cFP-21xx to an Ethernet hub, or use an Ethernet crossover cable to connect the controller directly to a computer. Caution To prevent data loss and to maintain the integrity of your Ethernet installation, do not use a cable longer than 100 m. If you are using a 100 Mbps Ethernet network, Nationa

Summary of the content on the page No. 15

6. Wire Power to the Compact FieldPoint System Each cFP-21xx on your network requires an 11–30 VDC power supply. 1. Connect the positive lead of the primary power supply to one of the V1 terminals and the negative lead to one of the C terminals. 11–30 VDC Backup Power Supply (optional) 2. If you are using a backup power – – supply, connect the positive lead to + + 11–30 VDC V2 and the negative lead to one of the Primary Power Supply C terminals. The cFP-21xx uses the power supply with th

Summary of the content on the page No. 16

7. Power Up the cFP-21xx Check the DIP switches on the controller, making sure that the RESET IP switch is in the OFF position. Plug in each power supply to the Compact FieldPoint system. The cFP-21xx runs a power-on self test (POST) that takes several seconds. You should see the POWER and STATUS LEDs come on. After about three seconds, the STATUS LED begins flashing steadily. The cFP-21xx is ready to be configured. If you have already assigned an IP address to the cFP-21xx, the STATUS LED

Summary of the content on the page No. 17

8. Install Software on the Host PC 1. Install the software packages you plan to use, such as LabVIEW, the LabVIEW Real-Time Module, Measurement Studio, VI Logger, or ™ ™ LabWindows /CVI , before you install the FieldPoint software. The FieldPoint software installation installs the LabVIEW VIs and examples and the LabWindows/CVI instrument driver only if it finds the corresponding development software installed. 2. Close all other applications. 3. Insert the National Instruments FieldPoint S

Summary of the content on the page No. 18

Compact FieldPoint Safety Information The following section contains important safety information that you must follow when installing and using Compact FieldPoint products. Do not operate Compact FieldPoint products in a manner not specified in the user manual or operating instructions. Misuse of the product can result in a hazard. You can compromise the safety protection built into the product if the product is damaged in any way. If the product is damaged, return it to National Instrument

Summary of the content on the page No. 19

Operate the product only at or below Pollution Degree 2. Pollution is foreign matter in a solid, liquid, or gaseous state that can reduce dielectric strength or surface resistivity. The following is a description of pollution degrees: � Pollution Degree 1 means no pollution or only dry, nonconductive pollution occurs. The pollution has no influence. � Pollution Degree 2 means that only nonconductive pollution occurs in most cases. Occasionally, however, a temporary conductivity caused by co

Summary of the content on the page No. 20

impulse withstand voltage levels that commonly occur in electrical distribution systems. The following is a description of measurement categories: � Measurement Category I is for measurements performed on circuits not 1 directly connected to the electrical distribution system referred to as MAINS voltage. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equip


Alternative user manuals
# User manual Category Download
1 National Instruments 1192 User manual Switch 1
2 National Instruments 6024E User manual Switch 3
3 National Instruments 6023E User manual Switch 2
4 National Instruments 1191 User manual Switch 0
5 National Instruments 6025E User manual Switch 0
6 National Instruments 653X User manual Switch 0
7 National Instruments 7334 User manual Switch 0
8 National Instruments 7344 User manual Switch 2
9 National Instruments 7340 PCI User manual Switch 3
10 National Instruments 800 Series User manual Switch 0
11 National Instruments AT-MIO-16X User manual Switch 0
12 National Instruments 6527 User manual Switch 2
13 National Instruments DIO 6533 User manual Switch 1
14 National Instruments GPIB-BUF User manual Switch 0
15 National Instruments GPIB-COM User manual Switch 0
16 Sony 4-296-436-11 (2) User manual Switch 0
17 3Com 10/100BASE-TX User manual Switch 61
18 3Com 2226-SFP User manual Switch 688
19 3Com 16985ua.bk User manual Switch 10
20 3Com 10BASE-T User manual Switch 4