Summary of the content on the page No. 1
User’s Manual
POE-1200
POE-2400
IEEE 802.3af
12 / 24-Port Power over Ethernet
Web Management Injector Hub
Summary of the content on the page No. 2
Trademarks Copyright © PLANET Technology Corp. 2008. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness f
Summary of the content on the page No. 3
TABLE OF CONTENTS 1. INTRODUCTION ........................................................................................................................................... 1 1.1 PACKAGE CONTENTS .................................................................................................................................. 1 1.2 PRODUCT DESCRIPTION.............................................................................................................................. 1 1.3 HOW TO U
Summary of the content on the page No. 4
1. INTRODUCTION 1.1 Package Contents Check the contents of your package for following parts: ● IEEE 802.3af Power over Ethernet Injector Hub x1 ● User’s Manual x1 ● Quick installation guide x1 ● 19” rack mounting kit x1 ● Power cord x1 ● Rubber feet x 4 If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it
Summary of the content on the page No. 5
Figure 1-1 Power over Ethernet Application 1.3 How to Use This Manual This Web Smart Power over Ethernet Injector Hub User Manual is structured as follows: Section 2, Installation It explains the functions of POE-1200 / POE-2400 and how to physically install the POE-1200 / POE-2400. Section 3, Management It contains information about the software function of the POE-1200 / POE-2400. Section 4, Web Configuration The section explains how to manage the POE-1200 / POE-2400 t
Summary of the content on the page No. 6
1.4 Product Features Interface 24 / 48-Port RJ-45 STP 12 / 24-Port “Data input” 12 / 24-Port “Data + Power output” 1 10/100Base-TX Management port PoE Complies with IEEE 802.3af Power over Ethernet Mid-Span PSE Up to 12/24 IEEE 802.3af devices powered Support PoE Power up to 15.4 watts for each PoE ports Auto detect powered device (PD) Circuit protection prevent power interference between ports Remote power feeding up to 100m PoE Management Total PoE power budge
Summary of the content on the page No. 7
1.5 Product Specifications Product POE-1200 POE-2400 Hardware Specification “Data” 12 x RJ-45 STP 24 x RJ-45 STP Input Ports Interface “Data+Power” 12 x RJ-45 STP 24 x RJ-45 STP Output Ports Management Port 1 x RJ-45; 10/100Base-TX, auto-negotiation, auto-MDI LED System: Power x 1 Per PoE Port: PoE in Use x 1 Network Cable • 10Base-T: 2-Pair UTP Cat. 3, 4, 5, up to 100 m (328ft) • 100Base-TX: 2-Pair UTP Cat. 3, 4, 5, up to 100 m (328ft) • EIA/TIA- 568 100-ohm STP (100 m) Dimensio
Summary of the content on the page No. 8
2. INSTALLATION This section describes the hardware features and installation of these PoE Injector Hub on the desktop or rack mount. For easier management and control of the PoE Injector Hub familiarize yourself with its display indicators, and ports. Front panel illustrations in this chapter display the unit LED indicators. Before deploy the PoE Injector Hub please read this chapter completely. 2.1 Hardware Description The section describes the hardware of the POE-1200 / POE-2400
Summary of the content on the page No. 9
The following is the summary table of Reset button functions: Reset Button Pressed and Released Function About 1 second Reboot the PoE Injector Hub Reset the PoE Injector Hub to Factory Default configuration. The PoE Injector Hub will reboot and load the default IP settings as below: Until the SYS LED lit off 。 Default Password: admin 。 Default IP address: 192.168.0.100 。 Subnet mask: 255.255.255.0 。 Default Gateway: 192.168.0.254 To press the RESET button about 10 seconds and t
Summary of the content on the page No. 10
Figure 2-4 POE-2400 Rear Panel 1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It Power will prevent you from network data loss or network downtime. Notice: 2. In some area, installing a surge suppression device may also help to protect your device from being damaged by unregulated surge or current to the PoE Injector Hub or t
Summary of the content on the page No. 11
Step5: Supply power to the PoE Injector Hub. A. Connect one end of the power cable to the PoE Injector Hub. B. Connect the power plug of the power cable to a standard wall outlet. When the PoE Injector Hub receives power, the Power LED should remain solid Green. 2.2.2 Rack Mounting To install the PoE Injector Hub in a 19-inch standard rack, follow the instructions described below. Step1: Place your PoE Injector Hub on a hard flat surface, with the front panel positioned towards your fron
Summary of the content on the page No. 12
Figure 2-6 Mounting thePoE Injector Hub in a Rack Step6: Proceeds with the steps 4 and steps 5 of session 2.2.1 Desktop Installation to connect the network cabling and supply power to your PoE Injector Hub. 2.2.3 Network Application Installation The PoE Injector Hub is not equipment with data switching function between data ports. To inject PoE power and transmit data packets to PDs, the PoE Injector Hub is usually link to an Ethernet switch. Typically, the Mid-Span Injector is install
Summary of the content on the page No. 13
Figure 2-7 Network application installation The PoE Injector Hub supports Data passive mode, that is, even the PoE Injector Hub is manual power off, the data between “DATA” port and “DATA+PoE” port can still be transmitted without data loss. The POE-1200 / POE-2400 Mid-Span Injector Hub doesn’t support Gigabit data rate. The Ethernet switches or PoE PDs with Gigabit interface will operate at 100Mpbs Full Duplex mode when connect to the Mid-Span Injector Hub. 2.2.4 Power over Et
Summary of the content on the page No. 14
3 MANAGEMENT This chapter describes how to manage the Web Smart PoE Injector Hub. Topics include: - Overview - Management method - Logging on to the Web Smart PoE injector Hub 3.1 Overview The Web Smart PoE injector Hub provides a user-friendly, Web interface. Using this interface, you can perform various device configuration and management activities, including: System Power over Ethernet Tools 3.2 Requirements ■ Network cables. Use standard network (UTP) cables with RJ45
Summary of the content on the page No. 15
Figure 3-1 Web Management over Ethernet 2. When the following login screen appears, please enter the default username "admin" and password “admin” (or the password you have changed via console) to login the main screen of PoE Injector Hub. The login screen in Figure 3-12 appears. Default IP Address: 192.168.0.100 Default Account: admin Default Password: admin Figure 3-2 Login screen 1. For security reason, please change and memorize the new password after this first setup.
Summary of the content on the page No. 16
3.3.2 PLANET Smart Discovery Utility For easily list the PoE Injector Hub in your Ethernet environment, the Planet Smart Discovery Utility from user’s manual CD-ROM is an ideal solution. The following install instructions guiding you for run the Planet Smart Discovery Utility. 1. Deposit the Planet Smart Discovery Utility in administrator PC. 2. Run this utility and the following screen appears. Figure 3-3 Planet Smart Discovery Utility Screen If there are two LAN cards or above i
Summary of the content on the page No. 17
4. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version, Device IP Subnet address, also can assign new password, IP Subnet address and description for the devices. 5. After setup completed, press “Update Device”, “Update Multi” or “Update All” button to take affect. The meaning of the 3 buttons above are shown as below: Update Device: use current setting on one single device. Update Multi: use current setting on choose multi-devi
Summary of the content on the page No. 18
4 WEB CONFIGURATION The PoE Injector Hub provide Web interface for PoE smart function configuration and make the PoE Injector Hub operate more effectively - They can be configured through the Web Browser. A network administrator can manage and monitor the PoE Injector Hub from the local LAN. This section indicates how to configure the PoE Injector Hub to enable its smart function. 4.1 Manin Menu After a successful login, the main screen appears. The main screen displays the product name
Summary of the content on the page No. 19
4.2 Web Panel At the top of the Web management page, the active panel displays the link status of management port and PoE ports. Figure 4-2 Main menu screen Green lit is the network data send or receiver, Orange lit is the PoE in use. 4.3 System The System function allows viewing system information, IP Configuration and Password Setting. As showed in Figure 4-3. Figure 4-3 System screen The page includes the following information: Object Description System Information Displa
Summary of the content on the page No. 20
4.3.1 System Information The System information allows viewing system MAC Address, Software Version, Hardware Version, IP Address, Subnet Mask and Gateway.. As showed in Figure 4.4 Figure 4-4 System Information screen The page includes the following fields: Object Description MAC Address Specifies the PoE Injector Hub MAC address. Software Version The current software version running on the PoE Injector Hub . Hardware Version The current hardware version of the PoE Injector Hub.