Znyx Networks ZX4300P user manual

User manual for the device Znyx Networks ZX4300P

Device: Znyx Networks ZX4300P
Category: Switch
Manufacturer: Znyx Networks
Size: 0.12 MB
Added : 5/2/2014
Number of pages: 18
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Znyx Networks ZX4300P. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Znyx Networks ZX4300P.

For your convenience

If looking through the Znyx Networks ZX4300P user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Znyx Networks ZX4300P on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Znyx Networks ZX4300P to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Znyx Networks ZX4300P User manual - Online PDF
Advertisement
« Page 1 of 18 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Znyx Networks ZX4300P but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Znyx Networks ZX4300P. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




ZX4300P 10/100 ETHERNET SWITCH
USER'S GUIDE
Layer 2 CPSB Switch
Document No: DC0138-04

Summary of the content on the page No. 2

Copyright Notice ZNYX Networks 48421 Milmont Drive Fremont, CA 94538 USA Telephone: (510) 249-0800 or (800) 724-0911 Fax: (510) 656-2460 Email: sales@znyx.com support@znyx.com Website: www.znyx.com ZX4300P Series User's Guide Document # DC0138-04 September 26, 2001 ©2001 ZNYX Networks. All rights reserved worldwide. Information in this document is subject to change without prior notice. ZNYX Networks, RAIN, RAINlink, OpenArchitect are tradema

Summary of the content on the page No. 3

About this Manual This manual includes the installation, troubleshooting, and reference data for the ZX4300P 10/100 Ethernet Switch. See the ZNYX Networks data sheet for product specifications. All documentation for ZNYX Networks products, including data sheets, release notes and User's Guides are available for downloading from the ZNYX Networks website (http://www.znyx.com). Files are supplied in PDF format so your system requires Adobe Acrobat Reader to open and read the documenta

Summary of the content on the page No. 4

Overview Chapter 1 Overview of the ZX4300PSwitch The ZX4300P CompactPCI Ethernet 10/100 Mbps switch is the cost-effective and flexible solution to Embedded Carrier Class Layer 2 switching requirements. ZNYX Networks' ZX4300P is the first switch designed to support the upcoming PICMG 2.16 specification for a CompactPCI Packet Switching Backplane (CPSB), but it can also be deployed in a standard CompactPCI chassis by using one of three optional Rear Transition Boards (RTB). When installe

Summary of the content on the page No. 5

Overview Features of the ZX4300PSwitch The ZX4300P switch best satisfies the demand for high density, low cost, and high performance. It enables system architects to accelerate development of their next-generation CPSB products and achieve first-to-market deployment. • Designed for use in CompactPCI PICMG 2.16 fabric slots • Designed for standard CompactPCI chassis slots • Designed with 3 optional Rear Transition Board (RTB) configurations • Layer 2 switching • Non-blocking line-rate

Summary of the content on the page No. 6

Installation Chapter 2 Installation The ZX4300P is an unmanaged layer 2 switch requiring no software setup or configuration. Once the switch is installed in a chassis and power applied, it is fully operational as a layer 2 switch. Be sure to carefully follow the instructions for attaching the ZX4300P switch into an available 6U Compact PCI (cPCI) slot to prevent damage. For CPSB applications, the ZX4300P must be placed in a PICMG 2.16 compliant fabric slot. If you intend to use a Rear

Summary of the content on the page No. 7

Installation Installing the Rear Transition Board (RTB) 1. Remove the slot cover (or covers) from the corresponding rear panel bracket (slot filler) on your system. 2. Insert the correct Rear Transition Board into the slot. NOTE: Exercise extreme care when inserting the RTB card into the chassis. Improper alignment of the rear transition card connector with the rear panel connector pins can damage the pins. Your switch includes AB connectors to assist in properly aligning the RTB

Summary of the content on the page No. 8

SPD100 ACT LNK Installation Connecting the Cables The ZX4300P uses Broadcom's proprietary HP-AutoMDI-X technology that senses the cable attachment and adjusts it's internal Transmit and receive paths accordingly. The ports of the switch will auto-sense and correct for MDI (straight-through) or MDI-X (crossover) cabling. LED Reference The LED lights on the ZX4300P switch and corresponding Rear Transition Board (RTB) provide diagnostic and activity information during power up and normal u

Summary of the content on the page No. 9

Installation ZX4300P Series LED Reference Key LED Color Function Power up Display LNK (0-23) Green ON indicates a link is established OFF during power up. with the corresponding port. ACT (0-23) Yellow Flashing indicates activity on the OFF during power up. channel. SPD100 Green ON indicates the ethernet channel OFF during power up. OFF (0-23) is successfully linked at 100 Mb/s linked at 10Mb/s RESET Pressing RESET runs a lamp test to ensure all switch LEDs are operating and resta

Summary of the content on the page No. 10

Legal Notices and Certifications A. Legal Notices and Certification FCC Class A Notice: ZX4300P SERIES Pending THE ZX4300P IS FOR USE ONLY WITH COMPACT PCI BUS COMPATIBLE SYSTEMS THAT HAVE ENCLOSED POWER SUPPLIES WITH SELV OUTPUTS AND INSTALLATION INSTRUCTIONS DETAILING USER INSTALLATION OF CARD CAGE ACCESSORIES. Manufacturer Name: ZNYX Networks Manufacturer Address: 48421 Milmont Drive, Fremont, CA 94538 Warranty ZNYX Networks warrants to the original purchaser of any Z

Summary of the content on the page No. 11

Connector Pinouts B. J Connector Pin Assignments Standard and Extended Board J5 Pin Assignments 22 GND LP19_DA+ LP19_DA- GND LP19_DC+ LP19_DC- GND 21 GND LP19_DB+ LP19_DB- GND LP19_DD+ LP19_DD- GND GND LP18_DA+ LP18_DA- GND LP18_DC+ LP18_DC- GND 20 19 GND LP18_DB+ LP18_DB- GND LP18_DD+ LP18_DD- GND 18 GND LP17_DA+ LP17_DA- GND LP17_DC+ LP17_DC- GND GND LP17_DB+ LP17_DB- GND LP17_DD+ LP17_DD- GND 17 16 GND LP16_DA+ LP16_DA- GND LP16_DC+ LP16_DC- GND 15 GND LP16_DB+ LP16_DB- GND LP16

Summary of the content on the page No. 12

Connector Pinouts Extended Fabric Board J4 Pin Assignment 25 GND LP20_DA+ LP20_DA- GND LP20_DC+ LP20_DC- GND 24 GND LP20_DB+ LP20_DB- GND LP20_DD+ LP20_DD- GND 23 GND LP21_DA+ LP21_DA- GND LP21_DC+ LP21_DC- GND 22 GND LP21_DB+ LP21_DB- GND LP21_DD+ LP21_DD- GND 21 GND LP22_DA+ LP22_DA- GND LP22_DC+ LP22_DC- GND 20 GND LP22_DB+ LP22_DB- GND LP22_DD+ LP22_DD- GND 19 GND LP23_DA+ LP23_DA- GND LP23_DC+ LP23_DC- GND 18 GND LP23_DB+ LP23_DB- GND LP23_DD+ LP23_DD- GND 17 GND LP24_DA+ LP24_DA- GND

Summary of the content on the page No. 13

Connector Pinouts Standard and Extended Fabric Board J3 Pin Assignment 19 GND SGA4(4) SGA3(4) SGA2(4) SGA1(4) SGA0(4) GND 18 GND LPf_DA+ LPf_DA- GND LPf_DC+ LPf_DC- GND 17 GND LPf_DB+ LPf_DB- GND LPf_DD+ LPf_DD- GND 16 GND LP8_DA+ LP8_DA- GND LP8_DC+ LP8_DC- GND GND LP8_DB+ LP8_DB- GND LP8_DD+ LP8_DD- GND 15 GND LP7_DA+ LP7_DA- GND LP7_DC+ LP7_DC- GND 14 13 GND LP7_DB+ LP7_DB- GND LP7_DD+ LP7_DD- GND 12 GND LP6_DA+ LP6_DA- GND LP6_DC+ LP6_DC- GND (2) (2) LP6_DB+ LP6_DB- GND

Summary of the content on the page No. 14

Connector Pinouts Node & Fabric Board J2 Pin Assignment 22 GND GA4(3,7) GA3(3,7) GA2(3,7) GA1(3,7) GA0(3,7) GND (7,16) (7,16) (7,16) (7,16) (7,16) 21 GND GND (7,16) (7,16) (7,16) (7,16) (7,16) 20 GND GND (7,17) (7,17) SMB_ SMB_ SMB_ 19 GND GND (7,18) (7,18) (7,18) SDA SCL ALERT (7,17) (7,17) (7,17) (7,17) (7,17) 18 GND GND (7,17) (7,17) (7,17) (7,17) (7,17) 17 GND GND (7,17) (7,17) (7,17) (7,17) (7,17) 16 GND GND (7,17) (7,17) (7,17) (7,17) (7,17) GND GND 15 (7,17) (7,17) (7,17)

Summary of the content on the page No. 15

Connector Pinouts Node & Fabric Board J1 Pin Assignment (7) 25 GND 5V(8) ENUM#(15) 3.3V(8) 5V(8) GND (7) (7) (7) 24 GND 5V(8) V(I/O)(8) GND (7) (7) (7) 23 GND 3.3V(8) 5V(8) GND (7) (7) (7) 22 GND GND(8) 3.3V(8) GND (7) (7) (7) (7) 21 GND 3.3V(8) GND (7) (7) (7) GND GND(8) V(I/O)(8) GND 20 (7) (7) (7) 19 GND 3.3V(8) GND(8) GND (7) (7) (7) 18 GND GND(8) 3.3V(8) GND (7) GND 3.3V(8) IPMB_ SCL(7) IPMB_ GND(8) GND 17 SDA(7) (7) (7) (7) 16 GND GND(8) V(I/O)(8) GND (7) (7) (7) 15 GN

Summary of the content on the page No. 16

Connector Pinouts Notes for J Connector Pinouts from Previous Tables Sections referenced below pertain to the CompactPCI Packet Switching Backplane PICMG 2.16 Draft 0.6.5 June 19, 2001 1. BP(I/O) connects Front card to Rear card and does not connect to backplane. Refer to Section 3.1.1.2 for Alternate Node Board Keying Compliance. 2. GND for Type B style J3 connector. 3. Refer to Sections 3.3.2.3, 3.3.3.7, 3.3.5.1, 3.3.6.1, 4.3.5, 4.3.6, 4.4.1, and 4.4.10. 4. Refer to Sections 3.

Summary of the content on the page No. 17

Patch Panel Cable Specifications C. Patch Panel Cable Specifications The specifications required to build a cable for attaching the ZX4300P Series ZXRTB24R Rear Transition Board to a standard patch panel are on the following page. Contact your ZNYX Networks Sales Representative for assistance, or visit http://www.panduit.com. The diagrams below illustrate the cables when they are properly attached. Figure D-1 Cable Attached to the ZXRTB24R Figure D-2 Cable Attached to the P

Summary of the content on the page No. 18

Patch Panel Cable Specifications Ordering Information (from www.panduit.com) Depth Length Width Width Height Height No. of Part Number Part Description (in) (ft) (in) (mm) (in) (mm) Ports DP24584TV25 19" (482.6mm) W X 1.39" 1.39 19 482.6 1.72 43.7 24 (35.3mm) D X 1.72" (43.7mm) H DP48584TV25 19" (482.6mm) W X 1.39" 1.39 19 482.6 3.47 88.1 48 (25.3mm) D X 3.47" (88.1mm) H UTPCH8SR25 Straight, 110° , Right 8 Part Drawing orientation UTP


Alternative user manuals
# User manual Category Download
1 Znyx Networks bh5700 User manual Switch 0
2 Sony 4-296-436-11 (2) User manual Switch 0
3 3Com 10/100BASE-TX User manual Switch 61
4 3Com 2226-SFP User manual Switch 688
5 3Com 16985ua.bk User manual Switch 10
6 3Com 10BASE-T User manual Switch 4
7 3Com 10BASE-2 User manual Switch 1
8 3Com 1000BASE User manual Switch 6
9 3Com 2226 PLUS User manual Switch 473
10 3Com 2250-SFP User manual Switch 538
11 3Com 1600 User manual Switch 0
12 3Com 2924-PWR User manual Switch 72
13 Sony BZPS-8001 User manual Switch 1
14 Sony DFS-700P User manual Switch 123
15 Sony DVS-9000 User manual Switch 9