Summary of the content on the page No. 1
User’s Manual of WGSD-1022/WGSD-8000
User's Manual
WGSD-1022
8-Port 10/100Mbps
+ 2-Port Gigabit TP/SFP Combo
Managed Ethernet Switch
WGSD-8000
8-Port 10/100/1000Mbps
with 2 Shared SFP
Managed Ethernet Switch
- 1 –
Summary of the content on the page No. 2
User’s Manual of WGSD-1022/WGSD-8000 Trademarks Copyright © PLANET Technology Corp. 2007. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, perfor
Summary of the content on the page No. 3
User’s Manual of WGSD-1022/WGSD-8000 TABLE OF CONTENTS 1. INTRODUCTION ....................................................................................................................................................................14 How to Use This Manual......................................................................................................................................................14 Product Feature................................................................
Summary of the content on the page No. 4
User’s Manual of WGSD-1022/WGSD-8000 4.4.4 VLAN to Ports......................................................................................................................................................47 4.4.5 GVRP ..................................................................................................................................................................49 4.5 Statistics ...............................................................................................
Summary of the content on the page No. 5
User’s Manual of WGSD-1022/WGSD-8000 4.10.2 Bridge Multicast ...............................................................................................................................................121 4.10.3 Bridge Multicast Forward All ............................................................................................................................123 4.11 SNMP..................................................................................................................
Summary of the content on the page No. 6
User’s Manual of WGSD-1022/WGSD-8000 5.3.10 username.........................................................................................................................................................168 5.3.11 show users accounts .......................................................................................................................................168 5.4 Address Table Commands..............................................................................................
Summary of the content on the page No. 7
User’s Manual of WGSD-1022/WGSD-8000 5.6.1 copy...................................................................................................................................................................195 5.6.4 show startup-config............................................................................................................................................199 5.7 Ethernet Configuration Commands.............................................................................
Summary of the content on the page No. 8
User’s Manual of WGSD-1022/WGSD-8000 5.9.6 ip igmp snooping leave-time-out........................................................................................................................228 5.9.7 show ip igmp snooping mrouter.........................................................................................................................228 5.9.8 show ip igmp snooping interface ...................................................................................................
Summary of the content on the page No. 9
User’s Manual of WGSD-1022/WGSD-8000 5.15.3 channel-group..................................................................................................................................................252 5.15.4 show interfaces port-channel...........................................................................................................................253 5.16 Port Monitor Commands....................................................................................................
Summary of the content on the page No. 10
User’s Manual of WGSD-1022/WGSD-8000 5.20.2 snmp-server contact ........................................................................................................................................289 5.20.3 snmp-server location .......................................................................................................................................290 5.20.4 snmp-server enable traps ............................................................................................
Summary of the content on the page No. 11
User’s Manual of WGSD-1022/WGSD-8000 5.23.6 hostname.........................................................................................................................................................321 5.23.7 show users ......................................................................................................................................................321 5.23.8 show sessions .............................................................................................
Summary of the content on the page No. 12
User’s Manual of WGSD-1022/WGSD-8000 5.27.4 interface vlan ...................................................................................................................................................346 5.27.5 interface range vlan .........................................................................................................................................346 5.27.6 name.........................................................................................................
Summary of the content on the page No. 13
User’s Manual of WGSD-1022/WGSD-8000 5.29.14 show dot1x statistics......................................................................................................................................374 5.29.15 dot1x auth-not-req .........................................................................................................................................375 5.29.17 dot1x multiple-hosts...............................................................................................
Summary of the content on the page No. 14
User’s Manual of WGSD-1022/WGSD-8000 1. INTRODUCTION Thank you for purchasing PLANET Desktop Managed Switch- WGSD-1022 and WGSD-8000. If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair. Package Contents Check the contents of your package for following parts: • The WGSD Managed Switch x1 • CD
Summary of the content on the page No. 15
User’s Manual of WGSD-1022/WGSD-8000 Product Feature Physical Port WGSD-1022 8-Port 10/100Base-TX RJ-45 2 10/100/1000Base-T RJ-45 2 SFP slots, shared with Port-9(g1) and Port-10(g2) Console interface for Switch basic management and setup WGSD-8000 8-Port 10/100/1000Base-T RJ-45 2 SFP slots, shared with Port-7 and Port-8 Console interface for Switch basic management and setup Layer 2 Features Complies with the IEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z Gigabit Eth
Summary of the content on the page No. 16
User’s Manual of WGSD-1022/WGSD-8000 WEB-Based, Telnet, Console Command Line management SSH( Secure Shell), SSL Access through SNMPv1,v2c and v3 security set and get requests. Four groups (history, statistics, alarms, and events) of embedded remote monitoring (RMON) agents for network monitoring and traffic analysis Built-in Trivial File Transfer Protocol (TFTP) client Virtual Cable Test (VCT) technology provides the mechanism to detect and report potential cabling issues, such as
Summary of the content on the page No. 17
User’s Manual of WGSD-1022/WGSD-8000 Display each port’s speed duplex mode, link status, Flow control status. Port Status Auto negotiation status, trunk status. VLAN 802.1q Tagged Based VLAN ,up to 255 VLAN groups Supports 4 groups of 4-Port trunk support Link Aggregation IEEE 802.3ad LACP Traffic classification based on Port Number, 802.1p priority and DS/TOS field QoS in IP Packet IGMP Snooping Allow to be disabled or enable. Supports IGMP Snooping v1 and v2 RFC-1213 MIB-2 RF
Summary of the content on the page No. 18
User’s Manual of WGSD-1022/WGSD-8000 2. INSTALLATION This section describes the functionalities of the Switch's components and guides how to install it on the desktop or shelf. Basic knowledge of networking is assumed. Please read this chapter completely before continuing. 2.1 Product Description The PLANET WGSD-Series are Full Managed Desktop Switches with gigabit interfaces equipped. It boasts a high performance switch architecture that is capable of providing non-blocking switch fabri
Summary of the content on the page No. 19
User’s Manual of WGSD-1022/WGSD-8000 38400, N, 8, 1 8-Port Gigabit / 2 Shared SFP Managed Ethernet Switch LNK/ACT 1000 mini-GBIC PWR 1326 45 78 78 Figure 2-2 WGSD-8000 front panel. 2.1.3 LED Indications System LED Color Function PWR Green Lights to indicate that the Switch has power. Per 10/100Mbps port LED Color Function Lights to indicate the link through that port is successfully established. LNK/ACT Green Blink: indicate that the switch is actively sending or receiving dat
Summary of the content on the page No. 20
User’s Manual of WGSD-1022/WGSD-8000 2.0A Figure 2-4 WGSD-8000 rear panel Power Notice: 1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data loss or network downtime. 2. In some area, installing a surge suppression device may also help to protect your switch from being damaged by unregulated surge