Dynacord DTI 2000 user manual

User manual for the device Dynacord DTI 2000

Device: Dynacord DTI 2000
Category: Telephone
Manufacturer: Dynacord
Size: 0.53 MB
Added : 9/28/2014
Number of pages: 14
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Dynacord DTI 2000. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Dynacord DTI 2000.

For your convenience

If looking through the Dynacord DTI 2000 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Dynacord DTI 2000 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Dynacord DTI 2000 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Dynacord DTI 2000 User manual - Online PDF
Advertisement
« Page 1 of 14 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Dynacord DTI 2000 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Dynacord DTI 2000. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1



Owner’s Manual



DTI 2000
DIGITAL TELEPHONE INTERFACE
















DTI 2000 Manual e EDITED.doc 1

Summary of the content on the page No. 2

Contents *** Inhaltsverzeichnis Introduction This owner’s manual covers the installation, programming, and operation of DYNACORD’s DTI 2000 Digital Telephone Interface. Since operating and programming the DTI 2000 is similar to the operation and programming of a paging console, the DPM 4000 System handbook, the DPC 4000 paging console owner’s manual, and the Help Files of the PC Designer software may also be useful information sources. Characteristics The DTI 2000 is a micro process

Summary of the content on the page No. 3

Controls and Connections front view 1. POWER indicator The POWER LED lights when the DTI 2000 receives power input from the supplied power supply unit, which allows worldwide connection and use because it accepts input voltages between 85V AC and 250V AC. 2. SEIZE / DROP key (SELECT) This key allows manually accepting or cancelling phone calls and is mostly used for testing. When an incoming phone call is present (ringing), pressing the SEIZE

Summary of the content on the page No. 4

Rear 6. TO PAGING MANAGER connectors, female The two TO PAGING MANAGER connectors represent the interface to the DPM 4000 System Manager. Using either the 9-pole D-Sub connector or the 6-pole RJ-12 socket (simultaneous use of both terminals is not possible) to establish audio and data connection to the DPM 4000 is possible. The DTI 2000 needs to be connected to one of the paging console inputs (DPC IN, RJ-45 socket) on the DPM 4000. The needed interface cable (RJ-12 to RJ-45) with

Summary of the content on the page No. 5

Se Up and Connections 1. Unpacking The DTI 2000 package contains the following parts: 1 DTI 2000 Digital Telephone Interface 1 power supply unit, 100 – 240V AC 1 IEC mains cord 1 interface cable for DPM 4000 connection, RJ-12 to RJ-45 1 telephone cable, RJ-11 to TAE 1 owner’s manual Make sure that everything is complete and that nothing is damaged. Otherwise, immediately contact your dealer or the TELEX / EVI Audio service department. 2. DIP switch settings The DTI 2000 pro

Summary of the content on the page No. 6

2.2 Internal DIP switches (S202 and S203) To make any changes to the internal DIP-switch settings, you first have to remove the cover plate by loosening/removing the screws on the rear panel, as indicated in the diagram below. Remove these screws Loosen these screws Slightly lift the cover plate at the rear and remove it. Now you are able to change the DIP-switch settings. For installing the cover plate back in place, first position the case top in the guidan

Summary of the content on the page No. 7

than the specified maximum connection timeout setting allows. If the caller does not enter any new selection during the connection timeout, the DTI 2000 automatically finishes the momentary announcement and releases the PA-system. Afterwards, the telephone connection is disconnected as well. Switches 1 – 4 are used to set the maximum timeout for a connection as indicated in the following table: SW1 SW2 SW3 SW4 TIMEOUT OFF OFF OFF OFF OFF CAUTION: ON OFF OFF OFF 20 sec. OFF ON OFF OFF

Summary of the content on the page No. 8

Use one of the TO PAGING MANAGER sockets (not both simultaneously) for connecting the DTI 2000 to the DPM 4000. The DTI 2000 needs to be connected to a paging console input (DPC IN, RJ-45 socket) of the DPM 4000 using the supplied, 3.5m long interface cable (RJ-12 to RJ- 45). The following diagrams show the pin-assignment of sockets and cables. The LED labelled DATA is located next to the sockets. This LED lights during active data transmission between DTI 2000 and DPM 4000 System Manager pr

Summary of the content on the page No. 9

6. Country settings Different countries and regions have different telephone standards, which may differ in e.g. signal level and dial tones. The DTI 2000 can be and should be configured to meet those individual requirements. Not doing so can result in faulty operation of the DTI 2000. Generally, the DTI 2000 is factory pre-set prior to shipping. In case of problems, please contact the nearest service-centre or the technical support. Operating the DTI 2000 First, make sure that the

Summary of the content on the page No. 10

accepts the call and establishes a connection. First, you will hear a short noise (DTI 2000 line test) followed by different tone signals, which indicate that the DTI 2000 expects further entries. 2. Password Entry The DTI 2000 answers an incoming phone call with different tone signals, depending on its actual status. When not password-protected, a single tone signal indicates that the DTI 2000 is ready to accept a function command (via entering a one or two-digit function number). If pro

Summary of the content on the page No. 11

The DTI 2000 outputs a “High Busy” signal when one or several high priority zones are busy. A tone-sequence indicates that a text message is being played back. Text message playback normally stops automatically but manually stopping the function is possible as well by entering the STOP- function number code (default setting = 0 respectively 00). 6. Macros The DTI 2000 allows launching macros that are programmed in the DPM 4000 System Manager, thus providing access to special functions. Fo

Summary of the content on the page No. 12

2000 is recommended, because this is the only way to gain access to the total amount of 100 call numbers (accordingly to 100 paging console keys). Connect a DPC 4550 + DPC 4530 to the corresponding input at the DPM 4000 in the PC Designer Software, give it a meaningful name (e.g. telephone interface), and open the paging console dialog with a double-click on the paging console icon. The paging console dialog allows assigning one of the following functions per each call number (0 ... 99) re

Summary of the content on the page No. 13

60 TALK All groups 9 Starts an announcement in all zones with priority 9 … … … … … 70 MACRO Nr. 15 0 Triggers macro No. 15 71 MACRO Nr. 16 0 Triggers macro No. 16 … … … … … 99 CLEAR 0 0 Clears the actual zone / group selection 0 (or 00) STOP 0 5 Stops audio signals with a lower priority than 5, which have been launched from the DTI 2000 * TALK Current selection 3 Starts an announcement in the current selected zone(s) with priority 3 Setting the DTI 2000’s password codes is possible

Summary of the content on the page No. 14

Test Functions The processor system automatically runs an initial self-test whenever the DTI 2000 is connected to the mains. During this procedure, first the red DROP LED should light. Afterwards, the orange TALK LED blinks for approximately 3 seconds. In case faulty operation is being recognized, the processor system stops and the DROP and TALK LEDs light. Otherwise the DROP LED is dimmed and only the red DROP LED lights as long as a telephone connection has not been established. Pres


Alternative user manuals
# User manual Category Download
1 Edelbrock 2005-2007 (R) User manual Telephone 0
2 3Com VCX V7000 User manual Telephone 8
3 3Com CommWorks 5210 User manual Telephone 0
4 3Com NBX 900-0208 User manual Telephone 7
5 3Com Analog NBX User manual Telephone 0
6 3Com V7000 User manual Telephone 1
7 3Com NBX 3101SP User manual Telephone 98
8 3Com NBX 3101 User manual Telephone 13
9 3Com VCX V7000 User manual Telephone 2
10 3Com NBX 3102 User manual Telephone 17
11 A & T International TL7610 User manual Telephone 1
12 Sony CM-Z100SPR User manual Telephone 10
13 Aastra Telecom 470 User manual Telephone 46
14 Aastra Telecom 57i IP Phone User manual Telephone 16
15 Aastra Telecom 6753i R User manual Telephone 10