Bakers Pride Oven Ventless Hood System FH-28 user manual

User manual for the device Bakers Pride Oven Ventless Hood System FH-28

Device: Bakers Pride Oven Ventless Hood System FH-28
Category: Ventilation Hood
Manufacturer: Bakers Pride Oven
Size: 0.52 MB
Added : 4/6/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bakers Pride Oven Ventless Hood System FH-28. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bakers Pride Oven Ventless Hood System FH-28.

For your convenience

If looking through the Bakers Pride Oven Ventless Hood System FH-28 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bakers Pride Oven Ventless Hood System FH-28 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bakers Pride Oven Ventless Hood System FH-28 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bakers Pride Oven Ventless Hood System FH-28 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bakers Pride Oven Ventless Hood System FH-28 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bakers Pride Oven Ventless Hood System FH-28. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Ventless Hood System
MODEL FH-28
Installation & Operation Manual
Serial Numbers 123046 and higher





Summary of the content on the page No. 2

Warranty Information LIMITED ONE YEAR WARRANTY BKI (The "Company") warrants to the original purchaser that at time of shipment from the Company factory, this equipment will be free from defect in materials and workmanship. Written notice of a claim under this warranty must be received by the Company within ONE YEAR from the date of installation, but no longer than ONE YEAR AND THREE MONTHS from date of shipment from the factory. Defective conditions caused by abnormal use or misuse, la

Summary of the content on the page No. 3

Ventless Hood System Table of Contents Table of Contents Table of Contents........................................................................................................................................1 Introduction .................................................................................................................................................2 Safety Precautions....................................................................................................

Summary of the content on the page No. 4

Ventless Hood System Introduction Introduction Congratulations! You have chosen BKI’s Ventless Hood system, a state-of-the-art unit that filters grease laden air and returns it to the room. The BKI name and trademark on this unit assures you of the finest in design and engineering -- that it has been built with care and dedication -- using the best materials available. Attention to the operating instructions regarding proper operation, installation and maintenance will result in long

Summary of the content on the page No. 5

Ventless Hood System Introduction Specific Precautions Carbon monoxide poisoning will result from using this hood with any appliance that utilizes combustible fuel. Use only electrical appliances with this hood. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is not properly secured to the hood. A restraining device has been provided to assure that the appliance remains in the proper position under the hood during normal

Summary of the content on the page No. 6

Ventless Hood System Introduction Keep Safety Labels Clean and in Good Condition Do not remove or cover any safety labels on your equipment. Keep all safety labels clean and in good condition. Replace any damaged or missing safety labels. If you need new safety labels, contact: BKI Technical Services Department P.O. Box 80400 Simpsonville, S.C. 29680-0400 Or call toll free: 1-800-927-6887 Outside the U.S., call 864-963-3471 Prepare for Emergencies Be prepared

Summary of the content on the page No. 7

Ventless Hood System Introduction UL Information Failure to adhere to building, fire and electrical codes during installation of this unit could result in death, serious injury or property damage. The authority having jurisdiction, such as the local building inspector or fire marshal, should be consulted prior to installation to insure compliance with applicable codes. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is po

Summary of the content on the page No. 8

Ventless Hood System Introduction Fryers Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 60 Maximum Input 22 KW (3ph) 14.4 KW (1ph) Frequency 60 Hz Maximum normal frying temperature 375° F. (191° C.) Maximum shortening capacity 110 lbs. (50kg.) Maximum cooking surface area 396 sq. in. (2555 sq. cm.) USE ELECTRIC FRYERS AND SINGLE VAT FRYERS ONLY Griddles Specifications Volts 208/240 Phase 1 or 3 Maximum Amps 38.5 Maximum Input 8 KW Frequency 60

Summary of the content on the page No. 9

Ventless Hood System Operation Operation Principle of Operation A blower inside the ventless hood draws cooking vapors through a grease baffle. Inside the baffle, the air reverses direction two times capturing particles of moisture, grease, and dirt. Material collecting on the baffle drains into the condensation trough located below the baffle. After air passes through the baffle, it then enters a specially designed, high efficiency particle/odor filter where any particles that may have

Summary of the content on the page No. 10

Ventless Hood System Operation Shut-Down Power to the appliance is turned off, when the hood is turned off. For proper operation, always turn off appliance and allow time for it to cool before turning off the filter hood. This will insure proper capture of grease vapors. To stop the Filter Hood, press the “STOP” button. When to Replace the Filter The particle/odor filter should be replaced when the CHANGE FILTER light illuminates. In low to medium volume applications, the

Summary of the content on the page No. 11

Ventless Hood System Installation Installation Unpacking and Handling Inspection for Shipping Damage YOU are responsible for filing all freight claims with the delivering truck line. Inspect all cartons and crates for damage as soon as they arrive. If damage to cartons or pallets is found, or if a shortage is found, note this on the bill of lading (all copies) prior to signing and receiving. If damage is found when the equipment is opened, immediately call the delivering truck line a

Summary of the content on the page No. 12

Ventless Hood System Installation Leveling 1. Adjust the four feet provided on the bottom of the unit so there is a minimum of 6” clearance below the frame side members (NSF/UL REQUIREMENTS). 2. Check for level from side to side and front to back using a 4’ level placed appropriately on the frame. 10

Summary of the content on the page No. 13

Ventless Hood System Installation Securing Wall Mount After the hood has been located and leveled, secure to building by utilizing the .437 diameter holes provided in the rear of the fire extinguisher cylinder shelf (Refer to figure below). Using 1/4” lag screw(s), spacer(s) (if required), and anchor(s) (if required) secure the hood to a wall to prevent movement. The outside holes are spaced at 16 inches in the event wall studs can position the unit. Brace Mount If the unit is be

Summary of the content on the page No. 14

Ventless Hood System Installation Assembly and Mounting Fire Damper A UL Listed 165° F fusible link must be installed in the damper assembly located at the top of the unit. Install as follows: 1. Lift the damper. 2. Place the link on the damper hook. 3. Lower the damper while placing the link onto the stationary hook. Air Deflector Mount air deflector, as shown in the figure below, using two knurled screws (provided). 12

Summary of the content on the page No. 15

Ventless Hood System Installation Particle/Odor Filter 1. Remove the filter from the plastic bag. 2. Open the filter door on the front of the unit by rotating the handle counter-clockwise. 3. Observing the “UP” arrows on the filter, with a hand at each front corner, carefully slide the filter into the unit. 4. Close and latch the door. Appliance Stop FB37144203 (Used with BKI Automatic Lift Fryers) The Appliance Stop must be installed if a BKI Automatic Lift Fryer with M0084

Summary of the content on the page No. 16

Ventless Hood System Installation Appliance Restraining Device Install appliance-restraining device as shown in the figure below. In the event of an appliance fire, serious injury, property damage or death could occur if the appliance is not secured to the hood. A restraining device has been provided to assure that the cooking appliance remains in the proper position under the hood during normal operation. DO NOT REMOVE THE RESTRAINING DEVICE! Adjust restraining cable to allow no

Summary of the content on the page No. 17

Ventless Hood System Installation Fire Extinguishing System In the event of an appliance fire, serious injury, property damage or death could occur if any part of the appliance obstructs the spray nozzles. Ensure that lids and/or other parts of the appliance do not obstruct the spray pattern of either nozzle. The fire extinguishing system components used in this hood have been evaluated by U.L. in the course of their classification for use on this hood. An authorized Range

Summary of the content on the page No. 18

Ventless Hood System Installation 3. If required, connect the provided fire extinguishing system contacts for remote signaling (refer to the electrical diagram in this manual). 4. Adjust the position of the two ADP appliance nozzles as depicted below. 5. Reset control head. With control head NOT connected to cylinder, dry test system by activating the remote pull. 6. Install cylinder by placing bottom of cylinder over socket head screws at the bottom of cylinder bracket.

Summary of the content on the page No. 19

Ventless Hood System Installation The fire extinguishing system must be operative before the electrical system will function. Refer to the electrical diagram included in attached to this unit or in the service manual. Standard Electrical Connection This connection is for UL listed appliances supplied with a cord and a NEMA style 15-60 right angle plug. 1. Remove fire extinguisher access panel. 2. Route incoming power lines through holes located in the top of the 12”x8”x4” el

Summary of the content on the page No. 20

Ventless Hood System Installation 18


Alternative user manuals
# User manual Category Download
1 Bakers Pride Oven PB-24S User manual Ventilation Hood 0
2 Bakers Pride Oven PB-24 User manual Ventilation Hood 0
3 Sony SH-L35W User manual Ventilation Hood 0
4 Air King AIF8X User manual Ventilation Hood 3
5 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
6 Air King AIF10X User manual Ventilation Hood 0
7 Agilent Technologies 31A User manual Ventilation Hood 0
8 Air King 500CFM User manual Ventilation Hood 0
9 Agilent Technologies 6610XA User manual Ventilation Hood 1
10 Air King AIK14X User manual Ventilation Hood 0
11 Agilent Technologies HP 83621A User manual Ventilation Hood 0
12 Air King 380 CFM User manual Ventilation Hood 38
13 Agilent Technologies Agilent 86120C User manual Ventilation Hood 2
14 Air King AD series User manual Ventilation Hood 1
15 AEG DD 8665 User manual Ventilation Hood 4