Ele 45-9300 user manual

User manual for the device Ele 45-9300

Device: Ele 45-9300
Category: Cash Register
Manufacturer: Ele
Size: 0.09 MB
Added : 7/21/2014
Number of pages: 10
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Ele 45-9300. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Ele 45-9300.

For your convenience

If looking through the Ele 45-9300 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Ele 45-9300 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Ele 45-9300 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Ele 45-9300 User manual - Online PDF
Advertisement
« Page 1 of 10 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Ele 45-9300 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Ele 45-9300. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

International

Operating Instructions
VACUUM PYCNOMETER
Model: 45-9300 (AP-132)



Distributor:
ELE International, Inc. ELE International, Ltd.
PO Box 608 Chartmoor Road Chartwell Business Park
Loveland, CO 80539 Leighton Buzzard, Bedfordshire
USA LU7 4WG England
Phone: (970) 663-9780 Phone: + (0) 1525 249200
Fax: (970) 663-9781 Fax: + (0) 1525 249249
E-Mail: soiltest@eleusa.com E-Mail: ele@eleint.co.uk
Website: www.eleusa.com Website: www.eleint.co.uk

Summary of the content on the page No. 2

International TABLE OF CONTENTS I. GENERAL INFORMATION................................................................................................ 1 II. RELATED USER DOCUMENTATION............................................................................. 1 III. CALIBRATION................................................................................................................. 1 IV. OPERATION...........................................................................

Summary of the content on the page No. 3

International VACUUM PYCNOMETER MODEL 45-9300 (AP-132) I. GENERAL INFORMATION The 45-9300 (AP-132) Vacuum Pycnometer is designed to be used in determining the theoretical maximum specific gravity of bituminous paving mixtures, using the procedure described in ASTM standard test method D 2041 for type F containers. This large capacity (approximately 10 liters) unit can easily handle samples up to 13.2 lbs (6 kg), minimizing segregation effects. Constructed of lightw

Summary of the content on the page No. 4

International IV. OPERATION A. Sample Preparation Follow the procedure outlined in ASTM D 2041 for separating the sample particles, oven-drying the sample, and cooling it to room temperature. B. Operation 1. Weigh the empty pycnometer without the lower water inlet hose and without the gauge and hose assembly on the top. Designate this weight as "B." 2. Place the prepared sample in the pycnometer and weigh the sample and pycnometer together, designating this weight as "C."

Summary of the content on the page No. 5

International 8. Open the water inlet valve to fill the pycnometer to the very top without leaving any air space. Be careful not to turn off the vacuum. Close the water inlet valve. 9. Using the quick-disconnect, detach the gauge-hose assembly from the top of the pycnometer. 10. If there is any air trapped in the pycnometer, reconnect the aspirator and vacuum gauge (using the quick-connect) and let more water in. 11. Close the water inlet valve. 12. Disconnect the water inlet

Summary of the content on the page No. 6

International V. CALCULATIONS If the test temperature is within +3° or -5°F of 77°F (+ 1.7° or - 2.8°C of 25°C), the following equation can be used to determine the maximum specific gravity of the sample, with an error of 0.001 points or less due to thermal effects: Where: A = Mass of the dry sample in air (grams) D = Mass of container when filled with water at 77°F (25° C) (grams) E = Mass of container filled with both water and sample at 77°F (25°C) (grams) Note:

Summary of the content on the page No. 7

International A. Pycnometer Not Getting Vacuum 1. Check 'O' ring to make sure it is clean and in good shape. If not, contact ELE/Soiltest for a replacement 'O' ring. 2. Check to make sure the water inlet valve is on tight. 3. Tighten the stopcock nut (at bottom of stopcock) of the water inlet valve. B. Air Bubbles Entering from the Water Inlet Valve 1. Check to make sure the water inlet valve is on tight. 2. Tighten the stopcock nut (at bottom of stopcock) of the water i

Summary of the content on the page No. 8

International 45-9301 (AP-131) Filtering Kit. Functions as water trap for vacuum pump. 45-9320 (AP-134) Manometer VIII. SPECIFICATIONS Capacity Approximately 10 liters; 6 kg (13.2 lbs) sample weight Construction Lightweight polycarbonate, with transparent upper half Gauge 2" (50.8 mm) diameter; 30" x 0.5 " Hg Aspirator Plastic; 3/8" pipe thread (included) Connections Water inlet valve; quick disconnect for vacuum gauge and hose Dimensions 10-3/4" (273 mm) o.

Summary of the content on the page No. 9

International FIGURE 1 . 7 Distributor: ELE International, Ltd. ELE International, Inc. Chartmoor Road Chartwell Business PO Box 608 Park Loveland, CO 80539 Leighton Buzzard, Bedfordshire USA LU7 4WG England Phone: (970) 663-9780 Phone: + (0) 1525 249200 Fax: (970) 663-9781 Fax: + (0) 1525 249249 E-Mail: soiltest@eleusa.com E-Mail: ele@eleint.co.uk Website: www.eleusa.com Website: www.eleint.co.uk

Summary of the content on the page No. 10

International GRAPHS 8 Distributor: ELE International, Ltd. ELE International, Inc. Chartmoor Road Chartwell Business PO Box 608 Park Loveland, CO 80539 Leighton Buzzard, Bedfordshire USA LU7 4WG England Phone: (970) 663-9780 Phone: + (0) 1525 249200 Fax: (970) 663-9781 Fax: + (0) 1525 249249 E-Mail: soiltest@eleusa.com E-Mail: ele@eleint.co.uk Website: www.eleusa.com Website: www.eleint.co.uk


Alternative user manuals
# User manual Category Download
1 Dodge PARA-FLEX GT User manual Cash Register 0
2 Casio 160CR User manual Cash Register 62
3 Samsung M-ER290 User manual Cash Register 362
4 Casio 140CR 140CR User manual Cash Register 220
5 Casio 140 CR User manual Cash Register 377
6 Philips 220WS8 User manual Cash Register 11
7 ABC Office ROYAL 110CX User manual Cash Register 718
8 Sony ER-A420 User manual Cash Register 9
9 Casio PCRT470 PCR-T470 User manual Cash Register 2252
10 Samsung SAM52M User manual Cash Register 9
11 Casio BT-9100 User manual Cash Register 168
12 Samsung SAM52 User manual Cash Register 5
13 Samsung ER-290 User manual Cash Register 332
14 Sony ER-A410 User manual Cash Register 0
15 Casio PCRT48S PCRT48S User manual Cash Register 3407