Hunter Fan ELLIPSE 90063 user manual

User manual for the device Hunter Fan ELLIPSE 90063

Device: Hunter Fan ELLIPSE 90063
Category: Ventilation Hood
Manufacturer: Hunter Fan
Size: 10.89 MB
Added : 8/26/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Hunter Fan ELLIPSE 90063. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Hunter Fan ELLIPSE 90063.

For your convenience

If looking through the Hunter Fan ELLIPSE 90063 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Hunter Fan ELLIPSE 90063 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Hunter Fan ELLIPSE 90063 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Hunter Fan ELLIPSE 90063 User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Hunter Fan ELLIPSE 90063 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Hunter Fan ELLIPSE 90063. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

ENGLISH ES L
See page 2 Vea la página 21
I n s t a l l a t i o n G u i d e
oñap

90063/90064 Ellipse Bath Ventilator with Light and Night Light
READ and SAVE THESE INSTRUCTIONS
41722-01 3/29/2006
41722_EngS_3.29.03.indd 1 3/29/06 10:54:38 PM

Summary of the content on the page No. 2

W a r n i n g TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: such as those published by the National Fire Prevention 1. Use this unit only in a manner intended by the manufacturer. Association (NFPA), and the American Society for Heating, If you have questions, contact the manufacturer at the phone Refrigeration and Air-Conditioning Engineers (ASHRAE), and number or address listed in the warranty. the local code authorities. 2. Before installing, servicing, or c

Summary of the content on the page No. 3

Check all the parts. 95044-01-000 D If damaged, call 1-888-830-1326 95022-01-000 E for replacements. 75190-01-000 F x5 A 03242-07-133 G 95492-01-000 H B * 74508-03-133 3/8” Cable Connector x2 I C 95510-01-000 * J 75184-01-133 K x2 I Extra Screws 95366-01/02-000 NOTE: Strain relief cable connector L * must be installed. Not Included. Included. Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes Before Installation NOTE: Remove all packing materials before instal

Summary of the content on the page No. 4

4 3 H E Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. 7 8 F G Remove the wiring cover screw. Remove the wiring cover. 4 41722-013/29/2006 41722-01 3/29/2006 41722_EngS_3.29.03.indd 4 3/29/06 10:54:44 PM

Summary of the content on the page No. 5

10 9 E C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page15 New Construction – attaching to joist A11

Summary of the content on the page No. 6

A13 Pull wires through the strain relief. A14 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White Night Light Red Night Light 3 Pin Light Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. A15 A16 F G • F Install the wiring cover plate. Make sure all Tighten the wiring cover plate screw. wiring connections are inside the box or under the wiring cover plate. 6 41722-013/29/2006

Summary of the content on the page No. 7

ON OFF A18 A17 0 H Connect 4” duct and vent to the outside. Tape joints. Connect wiring from the motor to the wiring cover plate. If ducting does not fit securely, an adapter may need to be purchased. A19 A20 H I Reinstall the motor by inserting the tabs and pushing up Secure the motor by tightening the 2 screws. into position. Make sure the wires are not pinched between the motor and the housing. A21 A22 Test the motor. If the motor does not run, check the plug Turn on the power source. con

Summary of the content on the page No. 8

A23 Go to step E1 on page 18 to attach grille. New Construction – suspended between joists B12 B11 E D 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of Slide the mounting rails into brackets. the joist based on the thickness of your sheetrock. B13 B14 1/8" Bit E Mark position of screws by using holes as a template. Drill a hole in the center of each outline. 8 41722-01 3/29/2006 41722-01 3/29/2006 41722_EngS_3.29.03.indd 8 3/29/06 10:54:53 PM

Summary of the content on the page No. 9

B15 B16 Insert screws, leaving space between the screw Attach the rails onto the screws. head and the joist. Screws are not provided. B18 B17 Pull wires through the strain relief. Tighten screws. B19 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White Night Light Red Night Light 3 Pin Black Light Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. 41722-013/29/2006 41722-01 3

Summary of the content on the page No. 10

B20 B21 F G • F Install the wiring cover plate. Make sure all Tighten the wiring cover plate screw. wiring connections are inside the box or under the wiring cover plate. B23 B22 H Connect 4” duct and vent to the outside. Tape joints. Connect wiring from the motor to the wiring cover plate. If ducting does not fit securely, an adapter may need to be purchased. B24 B25 H I Reinstall the motor by inserting the tabs and pushing up Secure the motor by tightening the 2 screws. into position. Make

Summary of the content on the page No. 11

ON OFF B27 B26 Turn on the power source. Test the motor. If the motor does not run, check the plug connection. B28 Go to step E1 on page 18 to attach grille. Existing Construction – accessible from above NO EXISTING FAN EXISTING FAN C11 OR Remove an existing fan and check to make sure the Use the motor housing as a template to mark position. opening is large enough to accommodate the new motor housing (9”x 9.75”). 41722-01 3/29/2006 41722-01 3/29/2006 11 41722_EngS_3.29.03.indd 11 3

Summary of the content on the page No. 12

9” C12 E D Cut out an opening for the housing. Slide the mounting rails into brackets. C13 C14 5/8 5/8 1/2 1/2 Position the correct depth mark at the bottom edge of the Mark position of screws by using holes as a template. joist based on the thickness of your sheetrock. C15 C16 1/8" Bit Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. 41722-01 3/29/2006 41722-01 3/29/2006 12 41722_EngS_3.29.03.in

Summary of the content on the page No. 13

C17 C18 Attach the rails onto the screws. Tighten screws. C20 C19 Connect 4” duct and vent to the outside. Tape joints. Pull wires through the strain relief. If ducting does not fit securely, an adapter may need to be purchased. C21 Tighten the strain relief screws. 41722-01 3/29/2006 41722-01 3/29/2006 13 41722_EngS_3.29.03.indd 13 3/29/06 10:55:07 PM

Summary of the content on the page No. 14

C22 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White Night Light Red Night Light 3 Pin Light Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. C23 C24 G • F Install the wiring cover plate. Make sure all Tighten the wiring cover plate screw. wiring connections are inside the box or under the wiring cover plate. C25 C26 H H Connect wiring from the motor to the wiring cover pla

Summary of the content on the page No. 15

ON OFF C27 C28 I Secure the motor by tightening the 2 screws. Turn on the power source. C29 C30 Go to step E1 on page 18 to attach grille. Test the motor. If the motor does not run, check the plug connection. Existing Construction – accessible only from below EXISTING FAN D11 D12 E Remove an existing fan and check to make sure the open- Move the housing into position above the ceiling ing is large enough to accommodate the new motor hous- ing (9”x 9.75”). 41722-013/29/2006 41722-01

Summary of the content on the page No. 16

D13 D14 Attach existing ducting to duct connector. Tape joints. Pull wires through strain relief. If ducting does not fit securely, an adapter may need to be purchased. D15 E Screw pre-loaded screws into joist or framing. D16 Ground Black Green 2 Pin Bare Copper White A Black Main Switch 1 (AC In) Fan Motor White White Night Light Red Night Light 3 Pin Light Black Light Red Switch 1 (AC In) *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. 41722-013/29

Summary of the content on the page No. 17

D18 D17 G • F Install the wiring cover plate. Make sure all Tighten the wiring cover plate screw. wiring connections are inside the box or under the wiring cover plate. D20 D19 H H Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. D21 D22 I Secure the motor by tightening the 2 screws. Turn on the power source. 41722-013/29/2006 41722-0

Summary of the content on the page No. 18

ON OFF D23 D24 Go to step E1 on page 18 to attach grille. Test the motor. If the motor does not run, check the plug connection. Attaching the Grille E1 E2 H K L Remove the thumbscrews. Remove glass. E3 E4 H J K Connect wiring harness. Slide light mount over posts and attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. 18 41722-01 3/29/2006 41722-01 3/29/2006 41722_EngS_3.29.03.indd 18 3/29/06 10:55:23 PM

Summary of the content on the page No. 19

E5 E6 J L Align glass and push up. Install 2 Max 60 Watt A-15 bulbs (Not Included) and 1 Max 7 Watt C-7 bulb (Not Included). Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wirin

Summary of the content on the page No. 20

Warranty Hunter Fan Company Bath Exhaust Fan LIMITED WARRANTY Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter bath exhaust fan: If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year after the date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the defective part free of charge for parts and labor performed


Alternative user manuals
# User manual Category Download
1 Hunter Fan 41787-01 User manual Ventilation Hood 0
2 Hunter Fan 42947-01 User manual Ventilation Hood 0
3 Hunter Fan 43041-01 User manual Ventilation Hood 0
4 Hunter Fan 43042-01 User manual Ventilation Hood 0
5 Hunter Fan 48054 User manual Ventilation Hood 0
6 Hunter Fan 81006 User manual Ventilation Hood 0
7 Hunter Fan 41953-01 User manual Ventilation Hood 0
8 Hunter Fan 81003 User manual Ventilation Hood 1
9 Hunter Fan 41949-01 User manual Ventilation Hood 0
10 Hunter Fan 81020 User manual Ventilation Hood 0
11 Hunter Fan 48055 User manual Ventilation Hood 0
12 Hunter Fan 81005 User manual Ventilation Hood 0
13 Hunter Fan 81007 User manual Ventilation Hood 0
14 Hunter Fan 81021 User manual Ventilation Hood 0
15 Hunter Fan 82005 User manual Ventilation Hood 0
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0