Miele DA 8-2 user manual

User manual for the device Miele DA 8-2

Device: Miele DA 8-2
Category: Ventilation Hood
Manufacturer: Miele
Size: 0.4 MB
Added : 7/26/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Miele DA 8-2. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Miele DA 8-2.

For your convenience

If looking through the Miele DA 8-2 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Miele DA 8-2 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Miele DA 8-2 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Miele DA 8-2 User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Miele DA 8-2 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Miele DA 8-2. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operating instructions for the
DA 8-2 Extractor

M.-Nr. 03 997 810

Summary of the content on the page No. 2

Description of the appliance Description of the appliance 1 2 6 5 4 3 2

Summary of the content on the page No. 3

Description of the appliance Description of the appliance The DA-8 Extractor draws cooking va- Data plate pors in through the grease filter c and Because the data plate is no longer exhausts them to the outside. visible once the appliance has been in- b Ventilation grill stalled, a 2nd data plate is supplied. It should be placed into the space pro- c Grease filter vided on page 11 of these instructions. d 5’’ (120 mm) diameter exhaust connection e Extraction warning label Do not install the DA

Summary of the content on the page No. 4

Help protect our environment Help protect our environment Disposal of packaging Disposal of your old machine The transport and protective packing is Old machines contain materials which mostly manufactured from the following can be recycled. Please contact your re-usable materials: local recycling center or scrap mer- chant about potential recycling pro- . . . Corrugated paper / cardboard - grams, before disposing of the ap- mostly from recycled materials. pliance. . . . Polyethylene foil (PE) -

Summary of the content on the page No. 5

Contents Contents Description of the appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Help protect our environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Warning and safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Cleaning and care . . . .

Summary of the content on the page No. 6

Warning and safety instructions Warning and safety instructions Before servicing, disconnect the Before installation and before using power supply by removing the fuse the appliance for the first time read or tripping the circuit breaker. Grasp these operating instructions care- the plug, not the cord, when unplugg- fully to avoid the risk of accidents ing from the wall. and damage to the appliance. Do not use an open flame beside the extractor. When turned on, the The appliance is intended for

Summary of the content on the page No. 7

Warning and safety instructions Warning and safety instructions Never leave the unit unattended If exhaust air is to be vented into a when cooking with oil or fat. Very chimney or ventilation duct no hot oil can ignite and damage the ex- longer serving other purposes, seek tractor. professional advice. Try to prevent drops of soup, Ensure there is sufficient ventilation sauce, etc., or residues from the in the room when the extractor is in grease filter from finding their way into operation. the

Summary of the content on the page No. 8

Warning and safety instructions Warning and safety instructions Disposal of an old appliance Before disposing of an old ap- pliance, cut the cable off the ap- pliance as close to the housing as possible. The plug and cord should be disposed of and not used elsewhere in the house (electric shock hazard). Text highlighted in boxes is of par- ticular importance, and should be read in conjunction with the warning and safety instructions. 8

Summary of the content on the page No. 9

Operation Operation Turn the extractor on before starting to Select a power setting strong cook: enough to clear the air: Turn the control knob f clockwise. Setting 1 = for normal operation. Setting 2 = for removing heavy cooking odors. After cooking Turn the control knob counter clock- wise to ”0“. 9

Summary of the content on the page No. 10

Cleaning and care Cleaning and care Before cleaning the extractor dis- Make sure that no particles from the connect it from the main electrical grease filter fall into the interior of supply (pull out the plug or trip the the appliance. If this does happen, circuit breaker). the Service Department will have to be called to clean the appliance, as the fan casing will need to be dis- Grease filter mantled. A re-usable metal grease filter is used to remove solid particles (oil, dust, etc.) Loosen b

Summary of the content on the page No. 11

After Sales Service After Sales Service In the event of problems you cannot The address of the nearest Service De- correct yourself, please contact partment is given on the back page. Your Miele Dealer When contacting the Service Depart- ment, please quote the Model and Ser- or ial No. of the appliance. The Miele Service Department Space for enclosed data plate 11

Summary of the content on the page No. 12

Electrical connection Electrical connection Electrical connection - CDN Electrical connection - USA The extractor is supplied with a 1.10 m The extractor is supplied with a 4 ft power supply cable ready for connec- cord ready for connection to a tion to a 120 VAC, 60 Hz supply. 120 VAC, 60 Hz power supply. Connec- The rated load is 110 W. Fuse rating is tion should be made in an appropriate 10 A. junction box. The rated load is 110 W. Fuse rating is 10 A. Caution: Make sure the power supply i

Summary of the content on the page No. 13

Appliance dimensions Appliance dimensions 3 3/8" 20 3/16" 14 3/16" 19 5/16" 3 1/16" 13

Summary of the content on the page No. 14

Installation instructions Installation instructions Depth Width Do not install the DA 8-2 directly (in (= Dimen- next to a gas hob. mm) sion B) (in mm) This extractor is designed for installa- tion between Combiset appliances. 2 zone Combiset It should always be installed between 1 combiset 490 265 two appliances, such as the grill and 2 combisets 490 558 3 combisets 490 851 deep fryer. 4 combisets 490 1144 5 combisets 490 1437 4 zone Combiset 1 combisets 490 560 2 combisets 490 1143 3 combise

Summary of the content on the page No. 15

Installation instructions Installation instructions Remove the ventilation grill and Depth Width grease filter. (in (= Dimen- inches) sion B) Unscrew the frame (2 screws) at the (in front and remove. inches) 2 zone Combiset Install the extractor into the cut-out, 1 combiset 19-5/16 10-7/16" from below the countertop, so that 2 combisets 19-5/16 22" the protruding front edge rests on 3 combisets 19-5/16 33-1/2" the countertop. 4 combisets 19-5/16 45-1/16" 5 combisets 19-5/16 56-9/16" Raise the

Summary of the content on the page No. 16

Exhaust connection Exhaust connection The exhaust ducting should be as Please read the ”Warning and short and straight as possible. Safety Instructions“ to avoid the danger of toxic fumes. The use of angled pipes should be avoided, as this will reduce the air The DA-8 extractor should be in- flow of the extractor. stalled in accordance with local and Only use ducting made of non- national building regulations. flammable material. The exhaust ducting may be angled The exhaust connection should be

Summary of the content on the page No. 17

Exhaust connections Exhaust connections Vent connection variations F 13" 5 1/8" D 7 1/2" 8 1/4" An opening of at least 135 mm (5-5/16") diameter must be cut in the kitchen cabinet in order to allow the In connection examples B and C, exhaust ducting to pass through. neither the KM 88 nor the KM 89 can be installed to the left of the Mount the fan so that the impeller DA 8, since it will not be possible to cannot be inadvertently reached by place a container beneath the oil

Summary of the content on the page No. 18

Exhaust connections Exhaust connections Calculation of exhaust ducting Example A pipe diameter of 5" should ensure trouble-free extraction up to a total pipe length of 5.4. meters (17 1/2 ft). Determine the total pipe length as fol- lows: Measure the total length of ducting needed. Add the length of additional ducting to this figure according to the num- Wall vent (1) 1.1 m 43’’ ber and type of bends (see table below). Flexible 90° bend (2) 0.3 m 12’’ Note Flexible pipe (3) 1.0 m 39’’ If the ex

Summary of the content on the page No. 19

19

Summary of the content on the page No. 20

Alteration rights reserved / 22 / 001 CDN, USA - 4698


Alternative user manuals
# User manual Category Download
1 Miele DA 219-3 User manual Ventilation Hood 4
2 Miele DA 219-2 User manual Ventilation Hood 10
3 Miele DA 220-4 User manual Ventilation Hood 19
4 Miele DA 216-2 EXT User manual Ventilation Hood 8
5 Miele DA 230-3 User manual Ventilation Hood 12
6 Miele DA 219-2 EXT User manual Ventilation Hood 9
7 Miele DA 249-4 User manual Ventilation Hood 13
8 Miele DA 188 User manual Ventilation Hood 5
9 Miele DA 189 User manual Ventilation Hood 1
10 Miele DA 216-2 User manual Ventilation Hood 17
11 Miele DA 217-2 User manual Ventilation Hood 13
12 Miele DA 229-2 User manual Ventilation Hood 22
13 Miele DA 250 User manual Ventilation Hood 5
14 Miele DA 251 User manual Ventilation Hood 1
15 Miele DA 3160 User manual Ventilation Hood 21
16 Sony SH-L35W User manual Ventilation Hood 0
17 Air King AIF8X User manual Ventilation Hood 3
18 Acme Kitchenettes Koolmaster PP-32 User manual Ventilation Hood 0
19 Air King AIF10X User manual Ventilation Hood 0
20 Agilent Technologies 31A User manual Ventilation Hood 0