Pentair VERTICAL GRID DE FILTERS S8D110 user manual

User manual for the device Pentair VERTICAL GRID DE FILTERS S8D110

Device: Pentair VERTICAL GRID DE FILTERS S8D110
Category: Water Dispenser
Manufacturer: Pentair
Size: 0.52 MB
Added : 7/2/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Pentair VERTICAL GRID DE FILTERS S8D110. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Pentair VERTICAL GRID DE FILTERS S8D110.

For your convenience

If looking through the Pentair VERTICAL GRID DE FILTERS S8D110 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Pentair VERTICAL GRID DE FILTERS S8D110 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Pentair VERTICAL GRID DE FILTERS S8D110 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Pentair VERTICAL GRID DE FILTERS S8D110 User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Pentair VERTICAL GRID DE FILTERS S8D110 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Pentair VERTICAL GRID DE FILTERS S8D110. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

VERTICAL GRID DE FILTERS
O W N E R’ S M A N U A L
INSTALLATION, OPERATION & PARTS
MODELS
S7D75 S8D110
This manual should be furnished to
the end user of this filter; its use will
reduce service calls and chance of in-
jury and will lengthen filter life.
Sta-Rite Pool/Spa Group U.S. PATENT NO. 4995523 (Other patents pending)
293 Wright Street, Delavan, WI 53115
International: 262-728-5551, FAX: 262-728-7550
www.starite.com
Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA
© 2004, St

Summary of the content on the page No. 2

VERTICAL GRID DE FILTERS To avoId unneeded service calls, prevent possible injuries, and get the most out of your filter, READ THIS MANUAL CAREFULLY! The Sta-Rite System 3 Vertical Grid DE Filter: • Is designed to filter water for swimming pools. • Is an excellent performer; durable, reliable. Table of Contents Safety Instructions .......................................................................................3 General Information..........................................................

Summary of the content on the page No. 3

READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your filter or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal in- jury, or major property damage if ignored. warns about hazards that can cause death, serious personal in- jury, or major property damage if ignored. warns about hazards that will or can cause minor personal injury

Summary of the content on the page No. 4

GENERAL INFORMATION • Clean a new pool as well as possible before filling pool and operating filter. Excess dirt and large particles of foreign matter in the system can cause seri- ous damage to the filter and pump. • With a diatomaceous earth (DE) filter system in place and operating cor- rectly, clean water is returned to the pool faster than pool water is being contaminated. A typical pool installation will require approximately one week to obtain and maintain the sparkle that your filter is

Summary of the content on the page No. 5

INSTALLATION Installation of filter should only be done by qualified, licensed personnel. Filter mount must: • Provide weather and freezing protection. • Provide space and lighting for easy access for routine maintenance. (See Figure 1 and Table II, Page 6, for space requirements.) • Be on a reasonably level surface and provide adequate drainage. • Be as close to pool as possible to reduce line loss from pipe friction. Piping: • Piping must conform to local/state plumbing and sanitary codes. •

Summary of the content on the page No. 6

SPECIFICATIONS D WATER OUTLET TO POOL A WATER INLET PUMPED FROM POOL E C Figure 2 – Filter Cycle B OUTLET 7.812(198.4) INLET WATER INLET 9.19(233.4) PUMPED FROM POOL 2" (51mm)Sta-Rite WASTE PORT TO Union Connections SEPARATION TANK FIGURE 1 – Dimensions in inches (mm) Figure 3 – Backwash Cycle TABLE II - SPACE REQUIREMENTS IN INCHES (MM) Model No. A B C* D E 1 1 S7D75 28 ⁄2(724) 42(1067) 7 36(914) 53 ⁄2(1359) 1 1 1 S8D110 32 ⁄2(826) 42 ⁄4(1074) 8 40(1020) 54 ⁄4(1378) 8.0 * Number of clamps. 6

Summary of the content on the page No. 7

INITIAL START-UP Be sure pump is OFF before starting procedure. Do not operate these filters at more than 50 PSI (345 kPa) under any circumstances! To prevent serious damage to the element fabric, NEVER run you DE filter without a diatomaceous earth precoat! To avoid damage to internal filter components, never change Hazardous pressure. handle position on control valve while pump is running. Can cause severe injury or major 1. Make sure all clamps are in place and knobs are securely hand-tight

Summary of the content on the page No. 8

FILTER DISASSEMBLY/ ASSEMBLY PROCEDURE To avoid equipment damage and personal injury, never change handle position on control valve while pump is running. BEFORE DISASSEMBLING FILTER: 1. STOP PUMP. 2. OPEN air release valve and drain fitting. 3. WAIT until all pressure is released and water drained from filter tank and system before loosening clamp knobs. Disassembly: 1. Backwash filter according to instructions under “Filter Backwash Procedure”, Page 9. 2. Stop pump. Hazardous pressure. 3. Open

Summary of the content on the page No. 9

CLEANING THE FILTER 1 When to Clean: 5 4 NOTICE: If installation does not allow backwashing, use manual cleaning proce- dure regularly (see Page 10). 1. With a new filter: A. Record filter operating pressure at startup. When pressure reaches 15 PSI (103kPa) above startup operation pressure, stop pump for 15-30 3 6 seconds to allow filtering cake to release. B. Restart pump to form new cake. Pressure should now be less than 10 PSI (69kPa) above startup operating pressure. 7 2 C. If pressure is s

Summary of the content on the page No. 10

9. If any DE remains on grids after backwashing, flush filter elements with garden hose to remove it. Be sure to comply with local code for waste DE disposal. 10. Follow instructions under 'Assembly', Page 8, to reassemble filter. 11. Follow 'Initial Start-up' procedure (Page 7, steps 4, 5, 6 and 7) to restart system. 12. Compare pressure reading on gauge with reading recorded after initial startup. The two readings should be very close; if not, do "Manual Filter Hazardous pressure. Can cause se

Summary of the content on the page No. 11

collars may need to be cleaned before reassembly. 10. Follow filter assembly procedure, Page 8. To avoid severe injury or major property damage, exactly follow instructions under “Assembly” (Page 8)! 11. If unit is returning to service, see “Initial Startup”, Page 7. 12. If cleaning is part of seasonal shutdown, see “Winterizing”, Page 12. CHEMICAL CLEANING Hazardous pressure. PROCEDURE Can cause severe injury or major property damage Before Disassembling Filter: from tank blow up. 1. STOP P

Summary of the content on the page No. 12

l2. If cleaning is part of seasonal shutdown, see “Winterizing”, Page 12. SYSTEM INSPECTION General: Wash outside of filter with a mild detergent and water. Rinse off with hose. NOTICE: DO NOT use solvents to clean filter; solvents may damage plastic components in system. NOTICE: Open air bleed valve and bleed all air from filter each time pump is stopped and restarted. Weekly Inspection: 1. Skimmer basket- remove debris. 2. Stop pump, release all pressure. Remove trap cover and basket, remove d

Summary of the content on the page No. 13

TROUBLESHOOTING GUIDE 1. Short Cycle between backwashes: NOTICE: Time between backwashes will vary with each installation and be- tween different areas of the country. The following causes and remedies are for cycle times shorter than normal for your area. A. Chlorine residual too low; maintain proper residual (consult pool pro- fessional for recommendation). B. Flow rate too high; restrict flow to rated capacity of filter (see instruc- tion plate on filter or specifications on Page 6). C. Filte

Summary of the content on the page No. 14

5 5 0 5 5 4 0 4 5 3 0 3 MODELS 2 21 1 3 S7D75 4 5 S8D110 6 8 7 9 20 10 19 17 11 18 12 14 13 16 14 1460 0497 15 REPAIR PARTS LIST Model No. Key Part No. Description S7D75 S8D110 12 Inch Gauge 33600-0023 33600-0023 2 Air Release Valve WC212-120P WC212-120P 3 Close Nipple 1/4 in. U37-16P U37-16P 4 Adapter Bushing 24900-0504 24900-0504 5 O-Ring 35505-1423 35505-1423 6 Upper Tank Shell Kit* 24851-9000 24851-9001 7 Filter Element Assembly 23900-1220 23900-1221 8 O-Ring U9-362 U9-362 9 Outlet Ass

Summary of the content on the page No. 15

1 2 FILTER ELEMENT ASSEMBLY FOR S7D75 3 Key Part No. Part No. No. Description Used 23900-1220 4 5 1 Wing Nut 2 35402-0074 6 7 2 Air Bleed Assembly 1 24800-0120 8 9 3 Manifold 1 24800-0100 4 Covered Element 12-7/16" 1 23900-1171 5 Covered Element 13-13/16" 2 23900-1170 6 Covered Element 16-1/2" 2 23900-0033 7 Covered Element 15-3/16" 2 23900-1174 1063 0497 8 Covered Element 12-7/16" 2 23900-1175 10 9 Covered Element 9-11/16" 2 23900-1173 11 10 Element Grid Support 1 23900-0350 11 Rod 2 23900-0

Summary of the content on the page No. 16

STA-RITE LIMITED WARRANTY Pumps, filters, skimmers, underwater lights (except bulbs), * Full warranty coverage is in effect for one year after instal- accessories and fittings manufactured by Sta-Rite are war- lation. The pro-rated warranty covers the tank only during ranted to be free of defects in material and workmanship for the 2nd through 10th year after installation. The amount cov- one (1) year from date of installation. ered decreases by 10% each year. (ie., 2nd year 90% covered, 3rd yea


Alternative user manuals
# User manual Category Download
1 Pentair filter User manual Water Dispenser 151
2 Pentair Clean & Clear Plus Cartridge Filter User manual Water Dispenser 34
3 Pentair VERTICAL GRID DE FILTERS S7D75 User manual Water Dispenser 11
4 Pentair Water Pool and Spa40106 Rev. H 05/05 User manual Water Dispenser 32
5 Pentair Water Pool and SpaModel 5600 & 5600 Econominder User manual Water Dispenser 574
6 Pentair Modular DE Filter PLDE36 User manual Water Dispenser 13
7 Pentair Modular DE Filter PLDE48 User manual Water Dispenser 2
8 Pentair SM/SMBW 2000 User manual Water Dispenser 9
9 Edelbrock 2475 User manual Water Dispenser 0
10 Sony 2 User manual Water Dispenser 3
11 ADTX User manual Water Dispenser 4
12 Agilent Technologies E4408B User manual Water Dispenser 16
13 AEG PWE9039M User manual Water Dispenser 15
14 Agilent Technologies 8156A User manual Water Dispenser 7
15 Agilent Technologies 8591E User manual Water Dispenser 7