Bunn H5X user manual

User manual for the device Bunn H5X

Device: Bunn H5X
Category: Water Dispenser
Manufacturer: Bunn
Size: 3.41 MB
Added : 8/10/2014
Number of pages: 25
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bunn H5X. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bunn H5X.

For your convenience

If looking through the Bunn H5X user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bunn H5X on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bunn H5X to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bunn H5X User manual - Online PDF
Advertisement
« Page 1 of 25 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bunn H5X but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bunn H5X. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

H5E, H5X
With Digital Control Board
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
To ensure you have the latest revision of the manual or to obtain the illustrated parts catalog, please visit
the Bunn-O-Matic website, at www.bunn.com. This is absolutely FREE, and the quickest way to obtain
the latest catalog and manual updates. Contact Bunn-O-Matic Corporation at 1-800-286-6070 to obtain
a

Summary of the content on the page No. 2

BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 po

Summary of the content on the page No. 3

CONTENTS Warranty .......................................................2 Introduction ..................................................3 User Notices .................................................3 Electrical Requirements ................................4 Plumbing Requirements ...............................5 Initial Set-Up .................................................5 Programming ................................................6 Draining the Dispenser ........................

Summary of the content on the page No. 4

ELECTRICAL REQUIREMENTS WARNING - The dispenser must be disconnected from the power source until specified in Initial Set-Up. Refer to Data Plate on the Brewer, and local/national electrical codes to determine circuit requirements. L2 RED L2 RED L2 RED L2 RED BLUE WHITE WHITE L2 L2 N N NEUTRAL NEUTRAL L1 BLACK L1 BLACK L1 BLACK L1 BLACK L1 BLACK L1 BLACK BROWN L1 L1 L1 GREEN GREEN G GREEN GREEN GRN/YEL GREEN GREEN G G 120 volt ac models 208 & 240 volt ac models 230 volt ac models Note: This elec

Summary of the content on the page No. 5

PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 90 psi 1 (138 and 620 kPa)from a ⁄2” or larger supply line. A shut-off valve should be installed in the line before the dis- penser. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 1 kPa). The water inlet fitting is ⁄4” flare. 1 3 NOTE - Bunn-O-Matic recommends ⁄4” tubing for installations of less than 25 feet and ⁄8” f

Summary of the content on the page No. 6

PROGRAMMING When power is applied to the dispenser, the display located on the bottom of the main circuit board will show the revision level of the software for 5 seconds, and then go to (-). While the tank is filling, the display will read (FIL). When the tank is full the display will return to (-). P3747 CENTER RIGHT LEFT BUTTON BUTTON BUTTON INITIAL PROGRAMMING OF THE CONTROL BOARD 1. Before programming any settings into the Control Board, confirm the correct machine selection is entered.

Summary of the content on the page No. 7

PROGRAMMING (Continued) LEVEL 2 PROGRAMMING FAHRENHEIT OR CENTIGRADE SELECTION, & RESTORING FACTORY DEFAULTS 1. To enter Level 2 Programming, press and hold the center button until H2 appears on the display (approximately 6 seconds). Release the center button, The display will show either FAH (Degrees in Fahrenheit) or CEn (Degrees in Centigrade). 2. Press and release the (+) or (-) buttons to alternate between FAH and CEn. 3. After setting FAH or CEn, to exit Level 2 Programming, press and re

Summary of the content on the page No. 8

DRAINING THE DISPENSER CAUTION - The dispenser must be disconnected from the power source throughout these steps. 1. Disconnect the dispenser from the power source. 2. Shut-off and disconnect the incoming water supply 3. Remove the 4-40 screws at the sides of the top panel. 4. Gently remove one of the grommets from the tank lid. 5. Insert a tube to the bottom of the tank and syphon ALL of the water out. NOTE - The dispenser must be full using the INITIAL SET-UP steps before reconnecting to the

Summary of the content on the page No. 9

TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be per formed only by qualified ser vice person- nel. • All electronic components have 120 – 240 volt ac and low voltage dc potential on their te

Summary of the content on the page No. 10

TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Equipment will not operate 2. Safety overflow switch Refer to Ser vice – safety overflow switch (cont.) for testing procedures. See page 18. Automatic refill will not oper- 1. No water Check plumbing and shut-off valves. ate after drawing hot water. 2. Water strainer/flow control (A) Direction of flow arrow must be point- ing towards dispenser. (B) Remove the strainer/flow control and check for obstructions. Clear or replace. 3. Saf

Summary of the content on the page No. 11

TROUBLESHOOTING (cont.) Problem Probable Cause Remedy Water boils continuously. 1. Temperature control Refer to Ser vice – electronic controls for testing procedures. See page 10. 2. Lime build-up Inspect the tank assembliy for excess lime deposits. Delime as required. CAUTION – T anks and tank components should be delimed reglarly depending on local water conditions. Exces- sive mineral build-up on stainless steel surfaces can initiate corrosive reactions resulting in s

Summary of the content on the page No. 12

SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Refer to Troubleshooting for assistance in determining the cause of any problem. Component Access WARNING – Disconnect the dispenser from the power source before the removal of any panel or the replace- ment of any component. P1770 The limit thermostat, liquid level probe, tank heater, and temperature sensor are located at the top of the dispe

Summary of the content on the page No. 13

SERVICE (cont.) Electronic Controls H5E, H5X LIQUID LEVEL CONTROL PROBLEM: Overflows Drain cup Unplug Ready Lamp Retry No Overflow Replace Ready Lamp ? Yes Drain cup Disconnect Probe Wire From Probe P1772 Short Probe Wire T o Chassis FIG. 1 ELECTRONIC CONTROL Retry Location: No Overflow Replace Probe The electronic control board is located inside the ? rear of the dispenser. Access will also be needed to the Yes temperature sensor, overflow tube temperature sensor, Drain cup Disconnect Wir

Summary of the content on the page No. 14

SERVICE (cont.) Electronic Controls (cont.) 4. Remove the pink wire from terminal 5 of the elec- tronic control assembly. Liquid Level Control Test Procedure 5. Check the voltage across terminals 1 & 4 of the 1. Disconnect the dispenser from the power source. electronic control board with a voltmeter. Connect 2. Check the voltage across terminals 3 & 4 of the the dispenser to the power source. The indication electronic control board with a voltmeter. Connect must be: the dispenser to the p

Summary of the content on the page No. 15

SERVICE (cont.) If voltage was present as described, reinstall the Electronic Controls (cont.) probe, the sensing function of the system is operating 7. Reconnect the pink wire to terminal 5 of the elec- properly. tronic control assembly. If voltage was not present as described, check the pink 8. Loosen the compression fitting, remove the probe probe wire and the green ground wire for continuity from the tank lid, and inspect it for mineral depos- and/or replace the probe. its. Replace it

Summary of the content on the page No. 16

SERVICE (cont.) Electronic Controls (cont.) If voltage was present as described, the temperature control of the system is operating properly. If voltage was not present as described, contact Bunn- O-Matic to order an electronic control board and tem- perature sensor for evaluation and proceed to #9. 6. Replace the electronic control board. T5 PNK to Liquid 7. Check the voltage across the tank heater terminals Level Probe with a voltmeter. Connect the dispenser to the T4 WHI or RED to Termina

Summary of the content on the page No. 17

This equipment is to be installed to comply with the Basic Plumbing Code of t l he Building Officia s and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) Limit Thermostat If voltage was present as described, reconnect the black Location: wire and proceed to #5. The limit thermostat is located on the tank lid. If voltage was not present as described, refer to the To test the limit thermostat, access

Summary of the content on the page No. 18

This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) Removal and Replacement: 1. Disconnect the black wires from the safety overflow Safety Overflow Switch switch. 2. Remove the nut beneath the copper overflow cup. 3. Remove the entire switch assembly from the cup. 4. Place the new switch assembly into

Summary of the content on the page No. 19

! WARNING SERVICE (cont.) 7. Check the solenoid valve for coil action. Connect Solenoid Valve the dispenser to the power source. Listen carefully Location: in the vicinity of the solenoid valve for a “clicking” The solenoid valve is located inside the rear of the sound after approximately 5 seconds, as the coil dispenser on the right side near the bottom. magnet attracts the plunger. To test the solenoid valve, access will also be needed 8. Disconnect the dispenser from the power source. to

Summary of the content on the page No. 20

This equipment is to be installed to comply with the Basic Plumbing Code of the Building Officials and Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the Food and Drug Administration (FDA). SERVICE (cont.) Tank Heater Removal and Replacement: Location: 1. Remove the wires to the tank heater. The tank heater is located in the tank lid. 2. Remove the 8-32 nuts from the tank heater flange. 3. Remove the tank heater. 4. Inspect the tank heater gasket and re


Alternative user manuals
# User manual Category Download
1 Bunn H5X User manual Beverage Dispenser 7
2 Bunn AFPO-3 SL User manual Water Dispenser 0
3 Bunn AFPO-3 User manual Water Dispenser 2
4 Bunn 39338.0001 User manual Water Dispenser 2
5 Bunn 10267 User manual Water Dispenser 0
6 Bunn AFPO-3 User manual Water Dispenser 0
7 Bunn FPGA-2 DBC User manual Water Dispenser 0
8 Bunn AFPO-2 SL User manual Water Dispenser 0
9 Bunn 39338 User manual Water Dispenser 0
10 Bunn EQHP-10 User manual Water Dispenser 0
11 Bunn dispenser User manual Water Dispenser 0
12 Bunn TITAN SINGLE 2 User manual Water Dispenser 0
13 Bunn HW2A User manual Water Dispenser 6
14 Bunn HW2 User manual Water Dispenser 15
15 Bunn EASY CLEAR H5X User manual Water Dispenser 1
16 Edelbrock 2475 User manual Water Dispenser 0
17 Sony 2 User manual Water Dispenser 3
18 ADTX User manual Water Dispenser 4
19 Agilent Technologies E4408B User manual Water Dispenser 16
20 AEG PWE9039M User manual Water Dispenser 15