Ultra Start 430 Series user manual

User manual for the device Ultra Start 430 Series

Device: Ultra Start 430 Series
Category: Automobile Alarm
Manufacturer: Ultra Start
Size: 1.09 MB
Added : 5/5/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Ultra Start 430 Series. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Ultra Start 430 Series.

For your convenience

If looking through the Ultra Start 430 Series user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Ultra Start 430 Series on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Ultra Start 430 Series to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Ultra Start 430 Series User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Ultra Start 430 Series but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Ultra Start 430 Series. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

INSTALL GUIDE
430 and 440 Series Vehicle Security Systems
WWW.ULTRASTARTERS.COM
Technical Support 866-698-5872 ext 0
Support@ultrastarters.com
FCC/ID Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
CAUTION: Changes or modifications not expressly approved by the part

Summary of the content on the page No. 2

TABLE OF CONTENTS Table Of Contents Page 2 Wiring Diagram Page 3 Installation Tips Page 4 Pre-Installation Suggestions Installation Suggestions Mounting The Module Installing The LED Installing The Program Button Under Hood Connections Mounting The Siren Wire Connectors Page 5 14 Pin Main Harness Connector 4 Pin Red Connector- Keyless Entry 2 Pin Connector Red- Plug-in LED 2 Pin Blue Connector- Plug-in Program Button 3 Pin White Connector- Aux. outputs 4 Pin White Connector- Addition sensor inpu

Summary of the content on the page No. 3

WIRING DIAGRAM *500ma negative output Orange (-) When Armed Gray *500ma negative output Trunk Release Connect to vehicles ignition wire Yellow Ignition Input Connect to constant power. 20amp input Red 12 Volt Input Connect to Siren wire. 2amp Maximum Brown Siren Output Black Connect to chassis ground Ground Input Connect to door pin. (+) when opened Purple Door Input Connect to door pin. (-) when opened Green Door Input Connect to hood and / or trunk pin Hood Input Blue

Summary of the content on the page No. 4

10 Pin Connector White (+) Park lights Park light output. Orange (-) When Armed Negative output when system is armed. Grey (-) Trunk Release Negative output for trunk release. 500ma max. Yellow Ignition Input Input from vehicles ignition wire. RedMain Power Input Constant 12 Volt input. Brown (+) Siren Output Positive output for siren. Black Ground Input System ground input. Purple (+) Door Input Positive door pin switch input. Green (-) Door Input Negative door pin switch input. Blue (-) Hood I

Summary of the content on the page No. 5

BASIC INSTALLATION Step 1 - Connect All Of the Following Wires 10 Pin Power Connector Black Ground Input System ground input. Yellow Ignition Input Input from vehicles ignition wire. Red Power Input Constant 12 Volt input. Brown (+) Siren Output Positive output for siren. White (+) Park lights Positive park light output. Green* (-) Door Input Negative door pin switch input. Purple* (+) Door Input Positive door pin switch input. *Test for door pin type (+ or -) then connect the appropriate wire (

Summary of the content on the page No. 6

PROGRAM OVERVIEW Program mode allows you to adjust the settings and options of your system. Your system has been intelligently designed by installers with years of experience. The system’s default settings do not require any program changes in most cases. However, this system does incorporate a advanced programming system with settings that can be easily adjusted Entering Program Mode To Enter Program Mode 1) Make sure ignition is in the off position. 2) Within three seconds turn the key ON the

Summary of the content on the page No. 7

Enter Program Mode Entering program mode is done by the following steps: 1) Make sure ignition is in the off position. 2) Turn the ignition key ON - OFF, leaving key in the OFF position. 3) Press and release the Valet button two times. 4) The siren will chirp one time to confirm entering program mode. ( If this does not happen, turn ignition off, wait five seconds and repeat steps 1-4). Passive / Active Arming To change settings: 1 - Enter Program Mode - (Ignition ON-OFF, followed by Valet 2 tim

Summary of the content on the page No. 8

Double Pulse Unlock To change settings: 1 - Enter Program Mode - (Ignition ON-OFF, followed by Valet 2 times) 2 - Press & release transmitter buttons in the following sequence #2 - #2 then #1. 3 - The siren will respond with the following: 1 Chirp Double Pulse Unlock 2 Chirps Single Pulse Unlock Repeat sequence to change selection Voltage / Door Pin Sensing To change settings: 1 - Enter Program Mode - (Ignition ON-OFF, followed by Valet 2 times) 2 - Press & release transmitter buttons in the fol

Summary of the content on the page No. 9

Transmitter Programming Follow the steps below to program the transmitters to the system s memory Step 1 - Turn the Ignition key ON then OFF - Leaving Key Off. Step 2 - Press and release the Program Button twice then press and hold. Step 3 - The siren will respond with five chirps to confirm Transmitter Program Mode. Note: If the siren does not respond, repeat Steps1&2 Step 4 - Continue to hold the Program Button and press lock button on each of the transmitter’s to be programmed(Maximum of 3 Di

Summary of the content on the page No. 10

Lock Doors & Arm The Alarm 1.Press & release the LOCK button on the remote transmitter. 2.The park lights will flash and the siren will chirp once. 3.The doors will lock. 4.The LED will start flashing within five seconds. Unlock Doors & Disarm The Alarm 1.Press & release the UNLOCK button on the remote transmitter. 2.The park lights will flash and the siren will chirp twice. 3.The doors will unlock. 4.The LED will stop flashing. Silent Arm And Disarm 1.Press & release the button three, then pres

Summary of the content on the page No. 11

Service Mode 1. The system must be disarmed and the ignition is turned OFF. 2.Press and release the lock and unlock buttons at the same time, then press and hold the lock button for five seconds. 3.The system will respond with five chirps and park light flashes to confirm that the system is in Valet mode. 4. The LED will stay ON steady to confirm Valet Mode. Exit Service Mode 1.Press and release the lock and unlock buttons at the same time, then press and hold the lock button for five seconds. 2

Summary of the content on the page No. 12

Negative Type Door Locks Positive Type Door Locks 87 87 87a 87a 86 85 86 85 30 30 5 Wire / Reverse Polarity Type Door Locks 87 87 87a 87a 86 86 85 85 30 30 Negative Park Lights- In some cases the park lights may flash erratically after installing the negative park light relay. To correct this issue add a diode between the coil pins of the relay as shown. Ground Add IN4001 Diode 87 as shown 87a 86 85 White 30 Negative park light output


Alternative user manuals
# User manual Category Download
1 Ultra Start 1250 User manual Automobile Alarm 19
2 Ultra Start 2250 User manual Automobile Alarm 4
3 Ultra Start 1655XR User manual Automobile Alarm 0
4 Ultra Start 22xx User manual Automobile Alarm 0
5 Ultra Start 2250M User manual Automobile Alarm 2
6 Ultra Start 2271M User manual Automobile Alarm 0
7 Ultra Start 1256M User manual Automobile Alarm 0
8 Ultra Start 23xx User manual Automobile Alarm 0
9 Ultra Start 1271M User manual Automobile Alarm 1
10 Ultra Start 3271M User manual Automobile Alarm 0
11 Ultra Start 3266M User manual Automobile Alarm 0
12 Ultra Start 4271M User manual Automobile Alarm 0
13 Ultra Start 42xx User manual Automobile Alarm 0
14 Ultra Start 4266M User manual Automobile Alarm 0
15 Ultra Start 43xx User manual Automobile Alarm 4
16 Philips 42HF7945D User manual Automobile Alarm 1
17 Aastra Telecom 600 User manual Automobile Alarm 0
18 Acumen CAT21 User manual Automobile Alarm 16
19 Alamo RX84 User manual Automobile Alarm 5
20 Samsung SPF-83H User manual Automobile Alarm 5