Omron M6 Comfort user manual

User manual for the device Omron M6 Comfort

Device: Omron M6 Comfort
Category: Blood Pressure Monitor
Manufacturer: Omron
Size: 0.7 MB
Added : 9/18/2014
Number of pages: 36
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omron M6 Comfort. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omron M6 Comfort.

For your convenience

If looking through the Omron M6 Comfort user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omron M6 Comfort on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omron M6 Comfort to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omron M6 Comfort User manual - Online PDF
Advertisement
« Page 1 of 36 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omron M6 Comfort but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omron M6 Comfort. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

English
Français
Deutsch
Italiano
Español
Nederlands
Automatic Blood Pressure Monitor

Model M6 Comfort
Türkçe
Instruction Manual
IM-HEM-7321-E-01-08/2013
2298869-1A

Summary of the content on the page No. 2

1 2 b b J N c d a O

Summary of the content on the page No. 3

A G K B C H L J D E I F H P V G Q W R X M Y S N Z AA AB H T AC H O AD AE U AF

Summary of the content on the page No. 4

English Français Deutsch Italiano Español Nederlands Automatic Blood Pressure Monitor Model M6 Comfort Türkçe Instruction Manual Check following components! Vérifier les composants suivants ! Controleer de volgende onderdelen! Prüfen Sie folgende Teile des Lieferumfangs! ! Controllare i componenti indicati di seguito! ¡Compruebe los siguientes componentes!

Summary of the content on the page No. 5

Contents Thank you for purchasing the OMRON M6 Comfort Automatic Blood Pressure Monitor. The OMRON M6 Comfort is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology. Intended Use This device is a digital monitor intended for use in measurin

Summary of the content on the page No. 6

Important Safety Information Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) Consult your physician before using the device in pregnancy including pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis. Do not use the device on the injured arm or the arm under medical treatment. Do not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion. EN Consult your physician b

Summary of the content on the page No. 7

Important Safety Information If there are any abnormalities during the measurement, remove the arm cuff. Do not use this device on infants or persons who cannot express their intentions. Do not inflate the arm cuff more than necessary. Do not use the device for any purpose other than measuring blood pressure. Use only the approved arm cuff for this device. Use of other arm cuffs may result in incorrect measurement results. Do not use a mobile phone or other devices that emit electromagnetic fiel

Summary of the content on the page No. 8

Important Safety Information (Battery Usage) Do not insert the batteries with their polarities incorrectly aligned. Use only 4 “AA” alkaline or manganese batteries with this device. Do not use other types of batteries. Do not use new and used batteries together. Remove the batteries if the device will not be used for three months or more. General Precautions EN • Do not forcibly crease the arm cuff or the air tube excessively. • Do not press the air tube while taking a measurement. • To unplug

Summary of the content on the page No. 9

1. Know Your Device Open the rear cover page to read the following: The alphabet in the rear cover page correspond to those in the body page. Monitor Display A P Display Memory symbol B Q Cuff wrap guide lamp USER ID symbol C R Memory button Average value symbol D S Weekly average button Systolic blood pressure E T START/STOP button Diastolic blood pressure F U Up/Down buttons Heartbeat symbol (Flashes during measurement) G USER ID selection switch H V Date/Time setting button Date/Time display

Summary of the content on the page No. 10

1. Know Your Device Display Symbols Irregular Heartbeat Symbol ( ) Normal Heartbeat When the monitor detects an irregular rhythm two or more times during the Pulse measurement, the irregular heartbeat symbol ( ) will appear on the Blood pressure display with the measurement values. An irregular heartbeat rhythm is defined as a rhythm that is 25% less or 25% Irregular Heartbeat EN Short Long more than the average rhythm detected while the monitor is measuring the Pulse systolic and diastolic

Summary of the content on the page No. 11

1. Know Your Device Blood Pressure Colour Indicator If your systolic or diastolic pressure is above the standard range (135 mmHg for the systolic blood pressure and/or 85 mmHg for the diastolic blood pressure), the blood pressure colour indicator will light in “orange” when the measurement result is displayed. If they are within the standard range, the blood pressure colour indicator will light in “green”. The JNC7* Guideline recommends the following guideline. General Guidelines for Blood Pr

Summary of the content on the page No. 12

2. Preparation 2.1 Battery Installation 1. Remove the battery cover. 2. Insert 4 “AA” batteries as EN indicated in the battery compartment. 3. Replace the battery cover. Notes: • When the low battery symbol ( ) appears on the display, turn the monitor off, then replace all batteries at the same time. Long life alkaline batteries are recommended. • The measurement values continue to be stored in memory even after the batteries are replaced. • The supplied batteries may have a shorter life. Dis

Summary of the content on the page No. 13

2. Preparation Open the rear cover page to read the following: The letter identifiers on the rear cover page correspond to those in the body of this page. 2.2 Setting the Date and Time Set the monitor to the correct date and time before taking a measurement for the first time. H 1. Press the Date/Time setting ( ) button. V The year flashes on the Date/Time display. 2. Push or button to change the year. Push button to confirm the year and then the month flashes. Repeat the same steps to change

Summary of the content on the page No. 14

3. Using the Device Open both the front and rear covers to read the following: The letter identifiers on the cover pages correspond to those in the body of this page. 3.1 Applying the Arm Cuff Remove tight-fitting clothing or tight rolled up sleeve from your left upper arm. EN Do not place the arm cuff over thick clothes. N J 1. Insert the air plug into the air jack securely. 2. Apply the arm cuff to your left upper arm. a The bottom edge of the arm cuff should be 1 to 2 cm above the elbow. O

Summary of the content on the page No. 15

3. Using the Device 3.2 How to Sit Correctly To take a measurement, you need to be relaxed and comfortably seated, under comfortable room temperature. Avoid bathing, drinking alcohol or caffeine, smoking, exercising or eating 30 minutes before taking a measurement. • Sit on a chair with your feet flat on the floor. c • Sit upright with your back straight. --- • Sit with your back and arm being supported. d • The arm cuff should be placed on your arm at the same level as your heart. --- 10

Summary of the content on the page No. 16

3. Using the Device 3.3 Taking a Measurement Notes: • To cancel a measurement, press the START/STOP button to release the air in the arm cuff. • Remain still while taking a measurement. The monitor is designed to take measurements and store the measurement values in the memory for 2 people using USER ID 1 and USER ID 2. EN 1. Select your USER ID (1 or 2). 2. Press the START/STOP button. The arm cuff starts to inflate automatically. START INFLATE DEFLATE COMPLETE If your systolic pressure is mo

Summary of the content on the page No. 17

3. Using the Device 3. Remove the arm cuff. 4. Press the START/STOP button to turn the monitor off. The monitor automatically stores the measurement result in its memory. It will automatically turn off after 2 minutes. Note: Wait 2-3 minutes before taking another measurement. Waiting between measurements allows the arteries to return to the condition prior to taking a measurement. Using the Guest Mode The monitor stores measurement values for 2 users in the memory. The guest mode can be used t

Summary of the content on the page No. 18

3. Using the Device 3.4 Using the Memory Function The monitor automatically stores the results up to 100 sets for each user (1 and 2). It can also calculate an average value based on the last 3 measurement values taken within 10 minutes. Notes: • If there are only 2 measurement values in the memory for that period, the average will be based on these EN 2 values. • If there is 1 measurement value in the memory for that period, this is displayed as the average. • If the memory is full, the mo

Summary of the content on the page No. 19

3. Using the Device To View the Average Value 1. Select your USER ID (1 or 2). 2. Press and hold the button for more than 3 seconds. Notes: • If the previous measurement was taken without setting the date and time, the average value is not calculated. • If there are no measurement values stored in the memory, the screen to the right is displayed. 14

Summary of the content on the page No. 20

3. Using the Device To View the Weekly Average Value The monitor calculates and displays weekly averages for the measurements taken in the morning and evening within 8 weeks for each user. Note: The week begins Sunday at 2:00. 1. Select your USER ID (1 or 2). EN 2. Press the button. The morning average for “THIS WEEK” appears on the display. Note: The morning hypertension symbol ( ) appears if the morning weekly average is above 135/85 mmHg. Press the button again, and the evening average fo


Alternative user manuals
# User manual Category Download
1 Omron 11-675D User manual Blood Pressure Monitor 53
2 Omron 11-675DNL User manual Blood Pressure Monitor 2
3 Omron 11-685NL User manual Blood Pressure Monitor 1
4 Omron ELITE 7300IT User manual Blood Pressure Monitor 36
5 Omron BP762 User manual Blood Pressure Monitor 151
6 Omron HBF 306C User manual Blood Pressure Monitor 330
7 Omron INTELLISENSE HEM-780 User manual Blood Pressure Monitor 220
8 Omron HBP-1300 User manual Blood Pressure Monitor 56
9 Omron Hem 907XL User manual Blood Pressure Monitor 55
10 Omron HEM712C User manual Blood Pressure Monitor 41
11 Omron BP785 User manual Blood Pressure Monitor 98
12 Omron HEM-711DLX User manual Blood Pressure Monitor 98
13 Omron M6 User manual Blood Pressure Monitor 878
14 Omron INTELLI 637IT User manual Blood Pressure Monitor 57
15 Omron Ne U22V User manual Blood Pressure Monitor 0
16 Philips 319 User manual Blood Pressure Monitor 0
17 Philips HF319 User manual Blood Pressure Monitor 9
18 Philips M3860A User manual Blood Pressure Monitor 17
19 Philips M3861A User manual Blood Pressure Monitor 4
20 Philips M5066A User manual Blood Pressure Monitor 51