Omron R3-1 Plus user manual

User manual for the device Omron R3-1 Plus

Device: Omron R3-1 Plus
Category: Blood Pressure Monitor
Manufacturer: Omron
Size: 1.22 MB
Added : 6/25/2013
Number of pages: 34
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omron R3-1 Plus. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omron R3-1 Plus.

For your convenience

If looking through the Omron R3-1 Plus user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omron R3-1 Plus on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omron R3-1 Plus to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omron R3-1 Plus User manual - Online PDF
Advertisement
« Page 1 of 34 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omron R3-1 Plus but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omron R3-1 Plus. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

HEM6022-E.book Page 1 Thursday, August 21, 2008 7:54 PM
Wrist Blood Pressure Monitor
Model R3-I Plus
EN
• Instruction Manual
FR
• Mode d’emploi
DE
• Gebrauchsanweisung
IT
• Manuale di istruzioni
ES
• Manual de instrucciones
NL
• Gebruiksaanwijzing
RU
• РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
AR
IM-HEM-6022-E-02-08/08
5320469-9B

Summary of the content on the page No. 2

HEM6022-E.book Page 2 Thursday, August 21, 2008 7:54 PM Contents Before using the unit Introduction ................................................3 Important Safety Information .................... 4 1. Overview ................................................ 6 2. Preparation ............................................ 8 2.1 Installing/Replacing the Batteries ....... 8 2.2 Setting the Date and Time ............... 10 Operating instructions 3. Using the Unit ..........................

Summary of the content on the page No. 3

HEM6022-E.book Page 3 Thursday, August 21, 2008 7:54 PM Before using the unit Introduction Thank you for purchasing the OMRON R3-I Plus Wrist Blood Pressure Monitor. This remarkable, compact and easy to use instrument is ideal for people who frequently monitor their own blood pressure. The small, pre-formed wrist cuff is very convenient and easy to apply. With a push of a button the OMRON Wrist Blood Pressure Monitor measures your blood pressure and pulse and displays the reading on a c

Summary of the content on the page No. 4

HEM6022-E.book Page 4 Thursday, August 21, 2008 7:54 PM Important Safety Information Consult your doctor during pregnancy, arrhythmia and arteriosclerosis. People with poor peripheral circulation may find that results for measurements taken at the wrist vary from those taken on the upper arm. Please read this section carefully before using the unit. Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. (General Usage) • Alwa

Summary of the content on the page No. 5

HEM6022-E.book Page 5 Thursday, August 21, 2008 7:54 PM Important Safety Information • Do not use a mobile phone, or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit. • Do not operate unit in a moving vehicle (car, airplane). (Battery Usage) • If battery fluid should get on your skin or clothing, immediately rinse with plenty of clean water. • Use only two “AAA” alkaline batteries with this unit. Do not use other types of ba

Summary of the content on the page No. 6

HEM6022-E.book Page 6 Thursday, August 21, 2008 7:54 PM 1. Overview Main Unit C A D E F B A. Display C. Wrist cuff B. Battery compartment D. MEM (Memory) button cover E. O/I START button F. SET button 6

Summary of the content on the page No. 7

HEM6022-E.book Page 7 Thursday, August 21, 2008 7:54 PM 1.Overview Display G H M I N J O K P L G. Systolic blood pressure M. Heartbeat symbol H. Diastolic blood pressure 1. Flashes during I. Average value symbol measurement. (Displayed when viewing 2. If flashing after value for the last three measurement measurements.) completed, or when J. Memory value symbol viewing results stored in (Displayed when viewing the memory, indicates values stored in memory) blood pressure out of K. Irre

Summary of the content on the page No. 8

HEM6022-E.book Page 8 Thursday, August 21, 2008 7:54 PM 2. Preparation 2.1 Installing/Replacing the Batteries 1. Remove the battery compartment cover by pulling it off in the direction of the arrow. 1) Grasp both ends of the battery cover. 2) Pull the cover off the 1 main unit. 1 2 2. Insert two identical 1.5V “AAA” alkaline (LR03) batteries in the battery compartment. Make sure their polarity (+/-) is aligned with the polarity (+/-) as indicated in the battery compartment. 8

Summary of the content on the page No. 9

HEM6022-E.book Page 9 Thursday, August 21, 2008 7:54 PM 2.Preparation 3. Put the battery cover back in place. Note: Be sure to set the date and time after installing or replacing the batteries. Refer to “2.2 Setting the Date and Time”. The measurement values continue to be stored in memory even after the batteries are replaced. Battery Life & Replacement If the battery low symbol ( ) appears on the display, replace both batteries at the same time. - When the battery low symbol ( ) starts

Summary of the content on the page No. 10

HEM6022-E.book Page 10 Thursday, August 21, 2008 7:54 PM 2.Preparation 2.2 Setting the Date and Time Your blood pressure monitor automatically stores up to 60 measurement values in its memory and calculates an average value based on the three most recent measurements taken within 10 minutes of the last reading. (If there are only two readings in memory for that period, the average will be based on two readings. If there is one reading in memory for that period, the average will be based

Summary of the content on the page No. 11

HEM6022-E.book Page 11 Thursday, August 21, 2008 7:54 PM 2.Preparation 4. Repeat steps 2 and 3 to set the month and day. 5. Repeat steps 2 and 3 to set the hour and minutes for the time. After all settings are completed the display may still be flashing. To confirm settings and shut off the unit press O/I START button. Note: EN The unit will automatically turn itself off after you press the SET button to confirm the minute setting when the batteries are installed for the first time. 11

Summary of the content on the page No. 12

HEM6022-E.book Page 12 Thursday, August 21, 2008 7:54 PM Operating instructions 3. Using the Unit 3.1 Applying the Wrist Cuff You can take a measurement on either your left or right wrist. Notes: • You can take a measurement on either your left or right wrist. The blood pressure can differ between your right and left wrist and therefore also the measured blood pressure values can be different. Omron recommends to always use the same wrist for a measurement. If the values between the two w

Summary of the content on the page No. 13

HEM6022-E.book Page 13 Thursday, August 21, 2008 7:54 PM 3.Using the Unit 2. Hold the bottom part of the wrist cuff and wrap it around the wrist while pulling so that it fits comfortably. Note: Unless the wrist cuff is wrapped securely around the wrist, it may not be possible to take correct measurements. Smooth the cuff with your fingers to ensure that it fits snugly around the wrist. Notes: • If the fastener is not wrapped securely around your wrist, the cuff may slip during mea

Summary of the content on the page No. 14

HEM6022-E.book Page 14 Thursday, August 21, 2008 7:54 PM 3.Using the Unit Taking a reading on the right wrist Measurements can also be made on the right wrist. Fit the unit on the right wrist as shown. 14

Summary of the content on the page No. 15

HEM6022-E.book Page 15 Thursday, August 21, 2008 7:54 PM 3.Using the Unit 3.2 Correct Posture Correct posture during measurement helps you get accurate results. You should also try to measure your blood pressure at the same time each day. Notes: • Do not take measurements after bathing, drinking alcohol, smoking, exercising or eating. • Do not move or talk during measurement. Sit comfortably with Position your arm so that your back straight, the unit is at the same hold your arm acros

Summary of the content on the page No. 16

HEM6022-E.book Page 16 Thursday, August 21, 2008 7:54 PM 3.Using the Unit 3.3 Taking a Reading 1. Press the O/I START button to start measurement. The wrist cuff will start to inflate automatically after the power is turned on. 2. After the unit has detected your blood pressure and pulse rate, the cuff automatically deflates and your blood pressure and pulse rate are displayed. Notes: • Sit still and do not talk or move until the measurement is completed. • Keep the unit at heart heigh

Summary of the content on the page No. 17

HEM6022-E.book Page 17 Thursday, August 21, 2008 7:54 PM 3.Using the Unit 3. Check the measurement result. The unit automatically stores blood pressure and pulse rate into its memory. Refer to “3.4 Using the Memory Function”. The time and date of the measurement are displayed alternately. 4. Undo the fastener and remove the unit. 5. Press the O/I START button to turn off the unit. If you forget to turn off the unit, it will shut itself off automatically after two minutes. EN 17

Summary of the content on the page No. 18

HEM6022-E.book Page 18 Thursday, August 21, 2008 7:54 PM 3.Using the Unit Symbol Information: • If your systolic or diastolic pressure is outside the standard range, the Heartbeat symbol ( ) will blink when the measurement result is displayed. Recent research suggests that the following values can be used as a guide to high blood pressure for measurements taken at home. Systolic Blood Pressure Above 135 mmHg Diastolic Blood Pressure Above 85 mmHg This criteria is for home blood pressure

Summary of the content on the page No. 19

HEM6022-E.book Page 19 Thursday, August 21, 2008 7:54 PM 3.Using the Unit What is Irregular Heartbeat? An irregular heartbeat is a Normal Heartbeat heartbeat rhythm that Pulse varies by more than 25% Blood pressure from the average heartbeat rhythm detected while the Irregular Heartbeat unit is measuring the Short Long systolic and diastolic blood Pulse pressure. If such an irregular rhythm Blood pressure is detected more than twice during measurement, the Irregular heartbeat symbol ( )

Summary of the content on the page No. 20

HEM6022-E.book Page 20 Thursday, August 21, 2008 7:54 PM 3.Using the Unit 3.4 Using the Memory Function This unit has a memory capable of storing 60 sets of readings. Every time you complete the measurement, the unit automatically stores blood pressure and pulse rate. If there are three readings within 10 minutes of the last reading, the average of the three readings is displayed. (If there are only two readings in memory for that period, the average will be based on two readings. If ther


Alternative user manuals
# User manual Category Download
1 Omron 11-675D User manual Blood Pressure Monitor 53
2 Omron 11-675DNL User manual Blood Pressure Monitor 2
3 Omron 11-685NL User manual Blood Pressure Monitor 1
4 Omron ELITE 7300IT User manual Blood Pressure Monitor 36
5 Omron BP762 User manual Blood Pressure Monitor 151
6 Omron HBF 306C User manual Blood Pressure Monitor 330
7 Omron INTELLISENSE HEM-780 User manual Blood Pressure Monitor 220
8 Omron HBP-1300 User manual Blood Pressure Monitor 56
9 Omron Hem 907XL User manual Blood Pressure Monitor 55
10 Omron HEM712C User manual Blood Pressure Monitor 41
11 Omron BP785 User manual Blood Pressure Monitor 98
12 Omron HEM-711DLX User manual Blood Pressure Monitor 98
13 Omron M6 User manual Blood Pressure Monitor 878
14 Omron INTELLI 637IT User manual Blood Pressure Monitor 57
15 Omron Ne U22V User manual Blood Pressure Monitor 0
16 Philips 319 User manual Blood Pressure Monitor 0
17 Philips HF319 User manual Blood Pressure Monitor 9
18 Philips M3860A User manual Blood Pressure Monitor 17
19 Philips M3861A User manual Blood Pressure Monitor 4
20 Philips M5066A User manual Blood Pressure Monitor 51