Maytag MDG31 user manual

User manual for the device Maytag MDG31

Device: Maytag MDG31
Category: Clothes Dryer
Manufacturer: Maytag
Size: 1.39 MB
Added : 7/5/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Maytag MDG31. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Maytag MDG31.

For your convenience

If looking through the Maytag MDG31 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Maytag MDG31 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Maytag MDG31 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Maytag MDG31 User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Maytag MDG31 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Maytag MDG31. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

MDG31 / MDG51 / MDG77
Installation/Operator Manual
AVERTISSEMENT: Assurez-vous de bien
WARNING: For your safety the information
suivre les instructions données dans cette
in this manual must be followed to
notice pour réduire au minimum le risque
minimize the risk of fire or explosion and
d’incendie ou d’explosion ou pour éviter
to prevent property damage, personal
tout dommage matériel, toute blessure ou
injury or death.
la mort.
— Do not store or use gasoline or other
— Ne pas entreposer ni

Summary of the content on the page No. 2

Retain This Manual in a Safe Place for Future Reference This product embodies advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble free operation. Only qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer. The following “FOR YOUR SAFETY” caution must be posted near the dryer i

Summary of the content on the page No. 3

Table of Contents _______ IMPORTANT You must disconnect and lockout the electric supply and the gas supply or the steam supply Safety Precautions ................................4 before any covers or guards are removed from the machine to allow access for cleaning, Specifications ........................................6 adjusting, installation, or testing of any equipment per OSHA standards. Installation Procedures ......................14 Location Requirements ................................

Summary of the content on the page No. 4

Do not operate steam dryers with more than 150 psi (10.34 Safety Precautions ____________________ bar) steam pressure. Excessive steam pressure can damage Warning the steam coil and/or harm personnel. For your safety, the information in this manual Replace leaking flexible hoses or other steam fixtures ! must be followed to minimize the risk of fire or immediately. Do not operate the dryer with leaking flexible explosion and to prevent property damage, personal injury, hoses. Personal injury

Summary of the content on the page No. 5

Exhaust duct outlet should be checked periodically for NOTES ____________________________________ blockages, and if any found, removed. ___________________________________________ Important A means of restraint must be used to prevent ! ___________________________________________ straining of the gas supply when the appliance is moved. ___________________________________________ An external means of power removal (disconnect device) must be provided by the installer. __________________________

Summary of the content on the page No. 6

6 Maytag Co. 113430-3

Summary of the content on the page No. 7

113430-3 Telephone: (641) 787-7000 7

Summary of the content on the page No. 8

MDG31 Specifications ________________________________________________________________ 13.61 kg MAXIMUM CAPACITY (DRY WEIGHT) 30 lb TUMBLER DIAMETER 30” 76.20 cm TUMBLER DEPTH 27” 68.58 cm 312.62 L TUMBLER VOLUME 11.04 cu ft TUMBLER/DRIVE MOTOR 1/4 hp 0.18 kW BLOWER/FAN MOTOR 1/2 hp 0.37 kW 49.23 cm DOOR OPENING (DIAMETER) 19-3/8” DOOR SILL HEIGHT 14-7/8” 37.78 cm WATER CONNECTION 3/4”-11.5 NH DRYERS PER 20’/40’ CONTAINER 12 / 28 DRYERS PER 48’/53’ TRUCK 34 / 38 VOLTAGE AVAILABLE 120v 1ø 2w

Summary of the content on the page No. 9

MDG31 Specifications ________________________________________________________________ 113430-3 Telephone: (641) 787-7000 9

Summary of the content on the page No. 10

MDG51 Specifications _________________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 50 lb 22.68 kg 93.98 cm TUMBLER DIAMETER 37” TUMBLER DEPTH 25-3/4” 65.41 cm TUMBLER VOLUME 16.02 cu ft 453.64 L 0.75 kW TUMBLER/DRIVE MOTOR 1 hp BLOWER/FAN MOTOR 1/2 hp 0.37 kW DOOR OPENING (DIAMETER) 27-3/8” 69.55 cm 40.64 cm DOOR SILL HEIGHT 16” WATER CONNECTION 3/4”-11.5 NH DRYERS PER 20’/40’ CONTAINER 10 / 22 DRYERS PER 48’/53’ TRUCK 28 / 30 VOLTAGE AVAILABLE 120-240v 1ø

Summary of the content on the page No. 11

MDG51 Specifications _________________________________________________________________ 113430-3 Telephone: (641) 787-7000 11

Summary of the content on the page No. 12

MDG77 Specifications ______________________________________________________________ MAXIMUM CAPACITY (DRY WEIGHT) 75 lb 34.02 kg 93.98 cm TUMBLER DIAMETER 37” TUMBLER DEPTH 35-1/2” 90.17 cm TUMBLER VOLUME 22.09 cu ft 625.52 L 0.75 kW TUMBLER/DRIVE MOTOR 1 hp BLOWER/FAN MOTOR 1/2 hp 0.37 kW DOOR OPENING (DIAMETER) 27-3/8” 69.53 cm 40.64 cm DOOR SILL HEIGHT 16” WATER CONNECTION 3/4”-11.5 NH DRYERS PER 20’/40’ CONTAINER 9 / 20 DRYERS PER 48’/53’ TRUCK 25 / 27 VOLTAGE AVAILABLE 120-240V 1ø 2,

Summary of the content on the page No. 13

MDG77 Specifications ______________________________________________________________ 113430-3 Telephone: (641) 787-7000 13

Summary of the content on the page No. 14

Installation Procedures _______________ Unpacking/Setting Up _________________ Installation should be performed by competent professional Remove protective shipping material (i.e., plastic wrap and in accordance with local, state, and country codes. In the optional shipping box) from the dryer. absence of these codes, the installation must conform to Important applicable American National Standards: ANSI Z223.1-LATEST EDITION (National Fuel Gas Code) or ANSI/NFPA NO. 70- Dryer must be transport

Summary of the content on the page No. 15

Domestic Type I (MDG31, MDG51 Only) A = 10-inches (25.4 cm) B = 11-inches (27.94 cm) EXAMPLE: For a bank of 4 MDG31 dryers, 2 unrestricted openings measuring 10-inches by 11-inches (25.4 cm by A = 6-inches (15.24 cm) B = 24-inches (60.96 cm) 27.94 cm) are acceptable. EXAMPLE: For MDG51, 2 unrestricted openings measuring Important 6-inches by 24-inches (15.24 cm by 60.96 cm) are acceptable. Make-up air must be free of dry cleaning solvent If a closet door is installed: unobstructed air openings a

Summary of the content on the page No. 16

Important Vertical Venting Exhaust back pressure measured by a When vertical dryer venting is used, the length of the ductwork ! manometer/magnehelic in the exhaust duct must from the dryer to the outside exhaust outlet, must not exceed be no less than 0 and must not exceed 0.6 in WC (1.48 12 feet (3.66 meters). The minimum diameter of this ductwork mb). must be at least 4-inches (10.16 cm) for XXXX, 6-inches (15.24 cm) for MDG31, and 8-inches (20.32 cm) for MDG51 Note and MDG77. Including

Summary of the content on the page No. 17

Important Electrical Information _________________ No more than 4 dryers should be connected to 1 ! Electrical Requirements main common duct. All electrical connections must be made by a properly licensed and competent electrician. This is to ensure that the electrical The illustration below shows the minimum cross-sectional installation is adequate and conforms to local, state, and area for multiple dryer round or square venting. These figures national regulations or codes of the country of o

Summary of the content on the page No. 18

Warning (Gas Models Only) Dryers built for use with a voltage between 200 ! and 240 must verify the input voltage during installation. If the nominal voltage is outside of the medium tolerances shown on the diagram below, adjust the autotransformer, located near the burner assembly. To adjust the autotransformer wiring, place the red wire on the appropriate tap (HIGH, MED, LOW) of the autotransformer. For additional wiring details, refer to the electrical diagram located on the inside of the c

Summary of the content on the page No. 19

Grounding Gas and Steam Models Only A ground (earth) connection must be provided and installed 120-240V Application with Neutral in accordance with local, state, and national regulations or codes of the country of origin. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFPA NO. 70-LATEST EDITION, or in Canada, the installation must conform to applicable Canada Standards: Canadian Electrical Codes Parts 1 & 2 CSA C22.1-1990

Summary of the content on the page No. 20

Important For ease of service, the individual gas supply line ! of each dryer must have its own manual shutoff valve. The dryer and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa) for non-CE dryers or 50 mb for CE dryers. Failure to isolate or disconnect the dryer from supply as noted can cause irreparable damage to the gas valve, voiding the warranty. Note The dryer m


Alternative user manuals
# User manual Category Download
1 Maytag Bravos W10163136A User manual Clothes Dryer 30
2 Maytag Bravos W10150660A User manual Clothes Dryer 3
3 Maytag Bravos W10260037A User manual Clothes Dryer 5
4 Maytag Bravos W10267625A - SP User manual Clothes Dryer 9
5 Maytag Bravos W10150661A User manual Clothes Dryer 5
6 Maytag Bravos W10201177B User manual Clothes Dryer 3
7 Maytag Bravos W10160250A User manual Clothes Dryer 0
8 Maytag Bravos W10201175A User manual Clothes Dryer 2
9 Maytag BRAVOS W10388781A-SP User manual Clothes Dryer 3
10 Maytag D-2 User manual Clothes Dryer 4
11 Maytag BRAVOS W10388780A User manual Clothes Dryer 4
12 Maytag Epic W10139629A User manual Clothes Dryer 1
13 Maytag User manual Clothes Dryer 12
14 Maytag DV316LG User manual Clothes Dryer 2
15 Maytag Epic W10150639A User manual Clothes Dryer 2
16 ACS 882.00284.00 User manual Clothes Dryer 0
17 ACS 255 CMF (85 User manual Clothes Dryer 0
18 ACS 380 M3 /hr) User manual Clothes Dryer 0
19 Philips 1.07E+23 User manual Clothes Dryer 1
20 Philips 1.07E+31 User manual Clothes Dryer 3