DeVilbiss FAC125 user manual

User manual for the device DeVilbiss FAC125

Device: DeVilbiss FAC125
Category: Air Compressor
Manufacturer: DeVilbiss
Size: 0.21 MB
Added : 10/18/2014
Number of pages: 12
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for DeVilbiss FAC125. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with DeVilbiss FAC125.

For your convenience

If looking through the DeVilbiss FAC125 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual DeVilbiss FAC125 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual DeVilbiss FAC125 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
DeVilbiss FAC125 User manual - Online PDF
Advertisement
« Page 1 of 12 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual DeVilbiss FAC125 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to DeVilbiss FAC125. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

OWNERS MANUAL FOR
PERMANENTLY LUBRICATED AIR COMPRESSOR
(For Home Use Only)
MODEL NO.
FA125
FAC125
TABLE OF CONTENTS
SPECIFICATION CHART
SAFETY GUIDELINES .......................................................... 1
WARRANTY ........................................................................ 2
MODEL NO. FA125 FAC125
Horsepower 1 -----
WARNING CHART ........................................................... 3-4
SCFM @ 40 psig 3.7 3.7
GLOSSARY ................................................

Summary of the content on the page No. 2

LIMITED WARRANTY ONE YEAR FROM DATE OF PURCHASE All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include: air compressors, *air tools, accessories, service parts, pressure washers, and generators used in consumer applications (i.e., personal residential household us

Summary of the content on the page No. 3

IMPORTANT SAFETY INSTRUCTIONS  SAVE THESE INSTRUCTIONS  IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUC- TIONS BEFORE USING THIS EQUIPMENT. HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT RISK OF BURSTING AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION: 1.FAILURE TO PROPERLY DRAIN DRAIN TANK DAILY OR AFTER EACH USE. CONDENSED WAT

Summary of the content on the page No. 4

HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT REPAIRS ATTEMPTED BY UNQUALIFIED ANY ELECTRICAL WIRING OR REPAIRS RISK OF PERSONNEL CAN RESULT IN SERIOUS REQUIRE ON THIS PRODUCT SHOULD BE ELECTRICAL SHOCK INJURY OR DEATH BY ELECTROCUTION. PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL IN ACCORDANCE WITH NATIONAL AND LOCAL ELECTRICAL CODES. ELECTRICAL GROUNDING: FAILURE TO MAKE CERTAIN THAT THE ELECTRICAL PROVIDE ADEQUATE GROUNDING TO THIS CIRCUIT TO WHICH THE COMPRESSOR IS PRODUCT COULD RESULT IN SE

Summary of the content on the page No. 5

GLOSSARY SCFM or CFM: Standard Cubic Feet per Minute; a unit of which the motor automatically re-starts is called "cut-in measurement of air delivery. pressure." PSIG or PSI: Pounds per square inch gauge. CUT-OUT PRESSURE: When you turn on your air com- CUT-IN PRESSURE: While the motor is off, air tank pressor and it begins to run, air pressure in the air tank pressure drops as you continue to use your accessory. begins to build. It builds to approximately 125 PSI before the When the tank pr

Summary of the content on the page No. 6

DESCRIPTION OF OPERATION Depending on the air requirements of each particular Air Compressor Pump: To compress air, the piston accessory, the outlet regulated air pressure may have to be moves up and down in the cylinder. On the downstroke, air adjusted while operating the accessory. is drawn in through the intake valves. The exhaust valves remain closed. On the upstroke of the piston, air is Outlet Pressure Gauge: The outlet pressure gauge compressed. The intake valves close and compressed

Summary of the content on the page No. 7

INSTALLATION AND BREAK-IN PROCEDURES GROUNDING INSTRUCTIONS Additional Regulators and Controls Since the air tank pressure is usually greater than that RISK OF ELECTRICAL SHOCK! IN THE EVENT which is needed, a regulator is employed to control the OF A SHORT CIRCUIT, GROUNDING REDUCES air pressure ahead of any individual air driven device. THE RISK OF SHOCK BY PROVIDING AN ESCAPE WIRE FOR THE ELECTRIC CURRENT. Separate air transformers which combine the function of THIS AIR COMPRESSOR MUST BE

Summary of the content on the page No. 8

OPERATING PROCEDURES 1. Before attaching air hose or accessories, make sure When you are finished: the OFF/AUTO lever is set to “OFF” and the air 6. Set the “OFF/AUTO” lever to “OFF”. regulator or shut-off valve is closed. 7. Turn the regulator counterclockwise and set the 2. Attach hose and accessories. outlet pressure to zero. 8. Remove the air tool or accessory. 9. Open the regulator and allow the air to slowly bleed from the tank. Close the regulator when tank TOO MUCH AIR PRESSURE CAUSES

Summary of the content on the page No. 9

TROUBLESHOOTING GUIDE PERFORMING REPAIRS MAY EXPOSE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES. PERSONAL INJURY MAY OCCUR. PRIOR TO ATTEMPTING ANY REPAIRS, UNPLUG THE COMPRESSOR AND BLEED OFF TANK AIR PRESSURE. PROBLEM CAUSE CORRECTION Excessive tank pressure - safety Pressure switch does not shut off mo- Move the pressure switch lever to the “OFF” position. tor when compressor reaches “cut- If the outfit doesn’t shut off, unplug. If the electrical valve pops off. out” pressure.

Summary of the content on the page No. 10

TROUBLESHOOTING GUIDE (Continued) PROBLEM CAUSE CORRECTION Air leak from safety valve. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Knocking Noise Defective check valve. Remove and clean, or replace. Compressor is not supplying Prolonged excessive use of air. Decrease amount of air usage. enough air to operate accesso- Compressor is not large enough for air Check the accessory air requirement. If it is higher ri

Summary of the content on the page No. 11

PARTS LIST OUTLET PRESSURE GAUGE TANK PRESSURE PRESSURE GAUGE SWITCH COMPRESSOR ASSEMBLY SAFETY VALVE AIR HOSE CHECK VALVE (Not Shown) REGULATOR AIR TANK ISOLATOR AIR HOSE DRAIN VALVE (Not Shown) PARTS AVAILABLE FOR THIS UNIT DESCRIPTION PART NUMBER REGULATOR..........................................CAC-4296-1 TANK PRESSURE GAUGE ......................GA-345 OUTLET PRESSURE GUAGE .................GA-345 SAFETY VALVE .....................................TIA-4150 DRAIN VALVE .....................

Summary of the content on the page No. 12

OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR (For Home Use Only) MODEL NO. FA125 FAC125 WARRANTY This product is covered by the DeVilbiss one year limited warranty. The warranty can be found in the General Manual or is available upon request. Attach Sales Receipt Here. Retain Original Sales Receipt as Proof of Purchase for Warranty Repair Work. DeVilbiss Air Power Company • 213 Industrial Drive  Jackson, TN 38301-9615


Alternative user manuals
# User manual Category Download
1 DeVilbiss DACE-7161-2 User manual Air Compressor 15
2 DeVilbiss FA752-3 User manual Air Compressor 7
3 DeVilbiss FA125 User manual Air Compressor 0
4 DeVilbiss FTV560V User manual Air Compressor 7
5 DeVilbiss FAC752-2 User manual Air Compressor 0
6 DeVilbiss FA125-1 User manual Air Compressor 4
7 DeVilbiss FA752-2 User manual Air Compressor 1
8 DeVilbiss FAC752-3 User manual Air Compressor 1
9 DeVilbiss MG5-OLSTAT-3A User manual Air Compressor 3
10 DeVilbiss MG4-OLENG-2B User manual Air Compressor 2
11 DeVilbiss D22073 User manual Air Compressor 1
12 DeVilbiss LN1080H23M-1 Owner's manual Air Compressor 0
13 Directed Electronics 350HV User manual Air Compressor 5
14 12Volt 12V6CF User manual Air Compressor 2
15 Alesis 3630 User manual Air Compressor 260
16 AllTrade 835533 User manual Air Compressor 1
17 AllTrade 835579 User manual Air Compressor 3