DOD PS-7 user manual

User manual for the device DOD PS-7

Device: DOD PS-7
Category: Carbon Monoxide Alarm
Manufacturer: DOD
Size: 0.26 MB
Added : 2/5/2014
Number of pages: 9
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for DOD PS-7. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with DOD PS-7.

For your convenience

If looking through the DOD PS-7 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual DOD PS-7 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual DOD PS-7 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
DOD PS-7 User manual - Online PDF
Advertisement
« Page 1 of 9 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual DOD PS-7 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to DOD PS-7. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


EXTRACTIVE GAS DETECTOR
OPERAT ION MANUAL
Model PS-7

For Administrators













• Operate this unit only after reading and fully understanding the content of this manual.
• This Operation Manual was written for administrator use. Instructions for the basic

operations of this unit are provided separately in the standard Operation Manual. Refer

to the Operation Manual when necessary.









Summary of the content on the page No. 2

Some of the settings on this unit (alarm settings, etc.) are password protected. This Operation Manual explains the following items: • Passwords • Changing settings 1 Passwords 1-1 Password-protected Settings • Span adjustment (Refer to 2-1 Span Adjustment) • 21vol% adjustment (Refer to 2-2 21Vol% Adjustment ) • The values of various settings (Refer to 2-3 Changing Setting Values) • The values of alarm settings (Refer to 2-4 Changing the Alarm Settings) 1-2 Releasing the Password

Summary of the content on the page No. 3

2 Changing Settings 2-1 Span Adjustment Toxic gas sensor unit : CDS-7 Combustible gas sensor unit : CHS-7 (1) Set to maintenance mode (MNT1 or MNT2). TROUBLE lamp (yellow) blinks. The “__” indication and the concentration value of the detected gas blink alternately. MNT1 or MNT2 is displayed at the bottom of the LCD screen. Left: Maintenance 1 (MNT1) Center: Normal mode Right: Maintenance 2 (MNT2) Pull back to open (2) Release the password lock. (Refer

Summary of the content on the page No. 4

2-2 21Vol% Adjustment Oxygen sensor unit: COS-7 (1) Set to maintenance mode (MNT1 or MNT2). TROUBLE lamp(yellow)blinks. The “__” indication and the concentration value of the Oxygen blink alternately. MNT1 or MNT2 is displayed at the bottom of the LCD screen. Left: Maintenance 1 (MNT1) Center: Normal mode Right: Maintenance 2 (MNT2) Pull back to open (2) Release the password lock. (Refer to 1-2 Releasing the Password Lock.) (3) Press the SPAN switch.

Summary of the content on the page No. 5

2-3 Changing Setting Values Some of the setting values of the unit can be changed. Those that can be changed are listed in the table below. The method for changing them is explained here. (1) Release the password lock. (Refer to 1-2 Releasing the Password Lock.) (2) Press the UP/DOWN switch (“ ” or “ ”) until the setting you wish to change ( “LCD Screen Indication” in the table below ) is displayed at the bottom right of UP/DOWN switch the LCD display. Setting to be chang

Summary of the content on the page No. 6

Each time the UP switch is pressed, it will move down the table to the next item. When the DOWN switch is pressed, it will move up one. (4) Change the value by using the UP/DOWN switches (“ ” or “ ”). When you are done, press the special command switch again, and the alternating display in the bottom right corner of the LCD display will become constant. The process is now finished. Default value LCD Toxic: The function Adjustable Screen Remarks CDS-7 Oxygen: to be set Range Indi

Summary of the content on the page No. 7

2-4 Changing the Alarm Settings The values of alarm settings on this unit can be changed. The method for changing them is explained here. (1) Release the password lock. (Refer to 1-2 Releasing the Password Lock.) (2) Press the AL switch until the alarm setting to be changed is displayed on the LCD display. (The bottom right of the screen, as in the table below.) The alarm setting for the actual gas concentration is displayed in the middle of the screen, and the Gas concentration

Summary of the content on the page No. 8

st nd H – H mode (1 level: Upper limit, 2 level: Upper limit) Full Scale nd 2 level gas alarm : ALARM 1 , ALARM 2 is displayed. Alarm contacts ZA1 and ZA2 are activated Alarm value is set by entering A2 ** st 1 level gas alarm : ALARM 1 is displayed. Alarm contact ZA1 is activated Alarm value is set by entering A1 ** 0ppm Normal state (No gas is detected) st nd L – L mode (1 level: Lower limit, 2 level: Lower limit) 25vol% 21vol%

Summary of the content on the page No. 9

Manual Revision History Edition No. Date Revisions GAE-019 July 2004 Additional copies of this Operation Manual are available. Contact the following address for ordering information. Manufacturer: New Cosmos Electric Co., Ltd. 2-5-4 Mitsuya-naka Yodogawa-ku Osaka 532-0036, Japan Phone 81-6-6309-1505 Fax 81-6-6309-1514 Distributor: DOD Technologies, Inc 740 McArdle Drive Unit C Crystal Lake, IL 60014 Phone 815-788-5200 Fax 815-788-5200 www.dodtec.


Alternative user manuals
# User manual Category Download
1 3M MACURCO GD-2 User manual Carbon Monoxide Alarm 20
2 Airflow Systems IAQ10 User manual Carbon Monoxide Alarm 1
3 Aico Ei261DENRC User manual Carbon Monoxide Alarm 1
4 Advantech PCI-1718 Series User manual Carbon Monoxide Alarm 1
5 3M MACURCO GD-6 User manual Carbon Monoxide Alarm 55
6 Aico Ei261ENRC User manual Carbon Monoxide Alarm 14
7 Airflow Systems IAQ50 User manual Carbon Monoxide Alarm 10
8 American Sensor CO900 User manual Carbon Monoxide Alarm 0
9 American Sensor CO910 User manual Carbon Monoxide Alarm 1
10 American Sensor CO920 User manual Carbon Monoxide Alarm 1
11 Bacharach 2800 User manual Carbon Monoxide Alarm 0
12 Bacharach DIOXOR 19-7043 User manual Carbon Monoxide Alarm 0
13 Bacharach 3015-4286 User manual Carbon Monoxide Alarm 1
14 Bacharach Fyrite Insight Residential Combustion Analyzer User manual Carbon Monoxide Alarm 5
15 Bacharach DIOXOR 19-7038 User manual Carbon Monoxide Alarm 0