Invacare 1148114 user manual

User manual for the device Invacare 1148114

Device: Invacare 1148114
Category: Oxygen Equipment
Manufacturer: Invacare
Size: 0.66 MB
Added : 3/16/2014
Number of pages: 24
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Invacare 1148114. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Invacare 1148114.

For your convenience

If looking through the Invacare 1148114 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Invacare 1148114 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Invacare 1148114 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Invacare 1148114 User manual - Online PDF
Advertisement
« Page 1 of 24 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Invacare 1148114 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Invacare 1148114. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Operator’s Manual

HomeFill
Oxygen Post Valve
Cylinder
HF2POST6
HF2POST9
HF2POSTD
“Caution: Federal law restricts this device to sale or
rental by or on order of a physician, or any other
practitioner licensed by the law of the State in which
he/she practices to use or order the use of this device.”
Dealer: This manual MUST be given to the end
user.
User: Before using this cylinder, read this
manual and save for future reference.
For more information regarding
Invacare products, parts, an

Summary of the content on the page No. 2

 WARNING DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS, AND INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR A QUALIFIED TECHNICIAN BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE INJURY OR DAMAGE MAY RESULT.  WARNING Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not

Summary of the content on the page No. 3

TABLE OF CONTENTS TABLE OF CONTENTS SPECIAL NOTES ...............................................4 RECEIVING INSPECTION ..................................4 INTENDED USE ................................................4 SECTION 1—GENERAL GUIDELINES ..................5 SECTION 2—FEATURES ....................................8 SECTION 3—TYPICAL PRODUCT PARAMETERS .................................................9 SECTION 4—INSPECTION AND COMPRESSOR INTERFACE .......................................

Summary of the content on the page No. 4

SPECIAL NOTES SPECIAL NOTES Signal words are used in this manual and apply to hazards or unsafe practices which could result in personal injury or property damage. Refer to the following table for definitions of the signal words. SIGNAL WORD MEANING DANGER Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Warning indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury

Summary of the content on the page No. 5

SECTION 1—GENERAL GUIDELINES SECTION 1—GENERAL GUIDELINES  WARNING SECTION 1 - IMPORTANT SAFEGUARDS contains important information for the safe operation and use of this product. DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as Owner’s Manuals, Service Manuals or Instruction Sheets supplied with this product or optional equipment. If you are unable to underst

Summary of the content on the page No. 6

SECTION 1—GENERAL GUIDELINES  WARNING DO NOT attempt to repair product. DO NOT immerse product in any kind of liquid. Store product in a clean area when not in use. Only use an Invacare Corporation HF2POST6BAG or HF2POST9BAG carrying bag. NEVER smoke in an area where oxygen is being administered. ALWAYS confirm prescribed dose before administering to patient and monitor on a frequent basis. DO NOT use if dirt or contaminants are present on or around cylinder, valve, product or connecting

Summary of the content on the page No. 7

SECTION 1—GENERAL GUIDELINES  WARNING NEVER oil or lubricate the cylinder fittings. NEVER use any penetrating oil or lubricant such as WD-40 or 3 in One. If connection difficulty is experienced verify that the cylinder fitting is being inserted straight down into the compressor coupler. If continued difficulty is experienced contact your supplier for assistance. DO NOT allow cylinders to tip or fall. Secure gas cylinders so they cannot fall. Ensure cylinder is always in upright position.

Summary of the content on the page No. 8

SECTION 2—FEATURES SECTION 2—FEATURES Toggle Valve Cylinder Fill Port FIGURE 2.1 Product Diagram ™ HomeFill 8 Part No 1148114

Summary of the content on the page No. 9

SECTION 3—TYPICAL PRODUCT PARAMETERS SECTION 3—TYPICAL PRODUCT PARAMETERS DIMENSIONS: HF2POST6: Weight 4.0 lbs (1.81 kg) HF2POST6: Overall Length 11.1 in. (2.8 cm) HF2POST6: Diameter 4.4 in. (11.1 cm) HF2POST9: Weight 5.0 lbs (2.27 kg) HF2POST9: Overall Length 14 in (35.5 cm) HF2POST9: Diameter 4.4 in (11.1 cm) HF2POSTD: Weight 6.30 lbs (2.85 kg) HF2POSTD: Overall Length 20.8 in (52.8 cm) HF2POSTD: Diameter 4.4 in (11.1 cm) STORAGE CONDITIONS TEMPERATURE: -40°F (-40°C) to 140°F (60°C) MAXIMUM

Summary of the content on the page No. 10

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE SECTION 4—INSPECTION AND COMPRESSOR INTERFACE ™ NOTE: Refer to the HomeFill Compressor Owner’s Manual for compressor operating instructions. Cylinder Prefill Inspection  WARNING All cylinders MUST be inspected before attempting to fill; otherwise, injury or damage may occur. NEVER smoke in an area where oxygen is being administered. NEVER use near any type of flame or flammable/explosive substances, vapors or atmosphere. NOTE: For this proced

Summary of the content on the page No. 11

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE External Examination NOTE: For this procedure, refer to FIGURE 4.1 on page 12. 1. Examine the outside of the cylinder for the following conditions and replace the cylinder if they exist: • Dents or dings • Arc burns • Oil or grease • Any other signs of damage that might cause a cylinder to be unacceptable or unsafe for use. 2. Examine the cylinder for evidence of fire or thermal damage. Evidence includes charring or blistering of the paint, or ot

Summary of the content on the page No. 12

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE ! DANGER Improper filling or abuse of this cylinder, or failure to follow these safety instructions may cause serious bodily injury or death. High pressure oxidizing gas vigorously accelerates combustion. DO NOT alter or modify cylinder or related components. DO NOT use Oil or Grease. Keep cylinder, cylinder valve, all equipment and connections free of oil and grease to avoid violent ignition resulting in serious bodily injury or death. ! WARNING F

Summary of the content on the page No. 13

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE 2. Ensure toggle valve is open. Open the toggle valve by rotating counterclockwise. 3. Examine the gauge on the connected conserver or regulator. Perform one of the following: • If the cylinder pressure is less than 1500 psig, fill the cylinder. Connect the cylinder to the compressor. Refer to Filling the Cylinder on page 13. • If the cylinder pressure is greater than 1500 psig., DO NOT attempt to fill this cylinder. It may not fill. Use cylind

Summary of the content on the page No. 14

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE CONSERVER/REGULATOR CONSERVER/REGULATOR INSTALLED REMOVED Gauge Toggle Valve Conserver/ Regulator Cylinder FIGURE 4.2 Component Identification 4. Remove the post valve cover (located on the cylinder) and the connector fillport covers (located on the compressor) (FIGURE 4.3). Connector Post Valve Cover Fillport Cover FIGURE 4.3 Fillport Covers 5. On the compressor unit, momentarily push DOWN on the outer ring (sleeve) of the connector fillpor

Summary of the content on the page No. 15

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE NOTE: If the outer ring (sleeve) is in the UP position (GREEN dots not visible), the connector fillport will not be able to accept the cylinder fillport. Pushing DOWN momentarily will reset the connector fillport (GREEN dots visible) to accept the cylinder fillport. PUSH Outer Ring (Sleeve) DOWN Connector Fillport GREEN Dots BEFORE COUPLING CYLINDER, PUSH DOWN ON SLEEVE UNTIL GREEN DOTS ARE VISIBLE. FIGURE 4.4 Resetting Connector Fillport 6. G

Summary of the content on the page No. 16

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE NOTE: Refer to Cylinder Fill Times on page 20 for the length of time it will take to fill the cylinder. DETAIL “B” DETAIL “A” Cylinder Cylinder Assembly Outer Ring Fillport (Sleeve) Compressor DETAIL “C” Power Switch Cylinder Fillport Outer Ring (Sleeve) Connector Compressor Cylinder PULL Fillport Cradle UP FIGURE 4.5 Connecting the Cylinder to the Compressor ™ HomeFill 16 Part No 1148114

Summary of the content on the page No. 17

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE 11. After the cylinder is full, press the compressor power switch to the Off (O) position (FIGURE 4.6). 12. Grasp the cylinder assembly (FIGURE 4.6). 13. With the other hand, grasp the outer ring (sleeve) of the connector fillport and push DOWN (FIGURE 4.6). 14. Lift up on the cylinder assembly to remove from the connector fillport (FIGURE 4.6). PUSH DOWN Outer Ring (Sleeve) Cylinder Cylinder Assembly Fillport Power Switch Connector Compresso

Summary of the content on the page No. 18

SECTION 4—INSPECTION AND COMPRESSOR INTERFACE  WARNING The fillport cover on the connector fillport and the post valve fillport MUST be replaced after filling and whenever not in use. If either of the fillport covers are missing contact your healthcare provider before using. 17. Place the fillport covers onto the connector fillport (located on the compressor) and post valve fillport (located on the cylinder) (FIGURE 4.7). 18. Install a CGA870 post valve compatible conserver or regulator a

Summary of the content on the page No. 19

SECTION 5—MAINTENANCE SECTION 5—MAINTENANCE 1. After each use, clean exterior of the product with a dry, lint free cloth only. 2. Store product in a clean area free from grease, oil, and other sources of contamination. CAUTION DO NOT use cleaning solutions. DO NOT immerse product in any kind of liquid. All repairs MUST be done by Invacare Corporation. ™ Part No 1148114 19 HomeFill

Summary of the content on the page No. 20

SECTION 6—CYLINDER FILL TIMES SECTION 6—CYLINDER FILL TIMES NOTE: All filling times are approximate and may vary on environmental conditions. * Cylinder Concentrator Flow Rate to Patient: Filling (Platinum 5 up to 3 L/min. and Platinum 10 up to 5 Times L/min) HF2POST6 HF2POST9 HF2POSTD NORMAL 1 hr 25 min 2 hr 20 min 3 hr 20 min MAXIMUM 1 hr 50 min 2 hr 45 min 3 hr 50 min Troubleshooting If post valve cylinder fails to function, try the following solutions. If problem cannot be corrected, cons


Alternative user manuals
# User manual Category Download
1 Invacare 20EX User manual Oxygen Equipment 0
2 Invacare 212EX User manual Oxygen Equipment 0
3 Invacare 636959 User manual Oxygen Equipment 2
4 Invacare 10 User manual Oxygen Equipment 1
5 Invacare 1126360 3 User manual Oxygen Equipment 0
6 Invacare 10L User manual Oxygen Equipment 1
7 Invacare 50EX User manual Oxygen Equipment 0
8 Invacare 5 User manual Oxygen Equipment 13
9 Invacare ACC220 User manual Oxygen Equipment 0
10 Invacare CE0123 User manual Oxygen Equipment 0
11 Invacare HF2E540M9 User manual Oxygen Equipment 0
12 Invacare HF2PCM2KIT User manual Oxygen Equipment 0
13 Invacare 211EX User manual Oxygen Equipment 0
14 Invacare HF2POST9 User manual Oxygen Equipment 0
15 Invacare HF2POSTD User manual Oxygen Equipment 0
16 3M 8110S User manual Oxygen Equipment 1
17 3M 7187 User manual Oxygen Equipment 1
18 3M 8210PLUS User manual Oxygen Equipment 1
19 3M 8214 User manual Oxygen Equipment 0
20 3M 8210 User manual Oxygen Equipment 6