Epson Weighing Indicator XK3190-A1+P user manual

User manual for the device Epson Weighing Indicator XK3190-A1+P

Device: Epson Weighing Indicator XK3190-A1+P
Category: Scale
Manufacturer: Epson
Size: 0.26 MB
Added : 8/7/2013
Number of pages: 22
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Epson Weighing Indicator XK3190-A1+P. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Epson Weighing Indicator XK3190-A1+P.

For your convenience

If looking through the Epson Weighing Indicator XK3190-A1+P user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Epson Weighing Indicator XK3190-A1+P on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Epson Weighing Indicator XK3190-A1+P to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Epson Weighing Indicator XK3190-A1+P User manual - Online PDF
Advertisement
« Page 1 of 22 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Epson Weighing Indicator XK3190-A1+P but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Epson Weighing Indicator XK3190-A1+P. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1










+P
XK3190-A1


Weighing Indicator


USER’ S GUIDE







Attention:
Please read this User’s Guide carefully when you use
the indicator!

Summary of the content on the page No. 2

+P X K 3 1 9 0 - A 1 1 . Specifications 2 . Installation 2.1 Front & Back View of Indicator 2.2 Keyboard Function 2.3 Connecting Loadcell to Indicator 3. Calibration 4. Operating Instructions 4.1 Starting and Starting auto zero setting at turning on 4.2 Manual Zero Setting (Semi-automatically setting zero ) 4.3 Tare Function 4.4 Connecting Scoreboard to Indicator 4.5 Connecting Pinter to Indicator 4.6 Connecting Serial Communication port to Indicator 4.7 Setting of Time and

Summary of the content on the page No. 3

+P X K 3 1 9 0 - A 1 1 Specification + 1 Model XK3190-A1 2 Sample rated 5~25 times / sec 3 Load cell sensitivity 1~ 2mv/v 4 Division 1/2/5/10/20/50/100 optional 5 Display 7-bits LED digital display 0.56” in character height and 7 status indicating. 6 Clock can display day/month/year and second/minute/hour 7 Scoreboard display interface Using serial output method : current loop signal, transmission distance ≤50m RS323 signal, transmission distance ≤30m 8 Communication

Summary of the content on the page No. 4

+P X K 3 1 9 0 - A 1 2. Installation 2.1 Front & Back View of the Indicator UNIT:KG 1 2 3 ACCU PRE-T FUN TARE ENTER 4 5 6 0 MONEY PRICE AUTO DATE TIME TARE STABLE CLEAR CHECK DATE STORE WEIGH 7 8 9 SET CALB TIME PRINT ZERO PRINT (Graph 2-1) Front View of Indicator * ACCU - accumulating FUN- function CALB – Calibrating ( 25 ) pins (15 ) pins

Summary of the content on the page No. 5

+P X K 3 1 9 0 - A 1 2.2 Keyboard Function Key Function 1 [ACCU],[ UNIT No meaning PRICE] 2 In calibration mode, pressing [PRE-TARE/2] , can input digital key “2”; In weighing mode, the key is used for presetting tare. 3 [DELETE/4] In calibration mode, pressing [DELETE/4], can input digital key “4”; In weighing mode, it is deleting function key , more details shown in episode “deleting”. 4 [CHECK/5] In calibration mode, pressing [CHECK/5], can input digital key “5”; In w

Summary of the content on the page No. 6

+P X K 3 1 9 0 - A 1 15 In calibration or parameters setting mode, pressing [weigh], it will exit from original calibration or setting mode and return to weighing mode. 2.3 Connecting Loadcell to Indicator 1. The 9-pin socket is used for the link-up of loadcell, which has been clearly shown in the graph 2-3. 2. The 4-pin shielded cable is used, +S must be short connected with +E, -S and -E. The indicator does not have the function of long distance compensation. 3. ▲ !Ind

Summary of the content on the page No. 7

+P X K 3 1 9 0 - A 1 3. Calibration According to the Graph 2-3, connecting Indicator and loadcell, and the indicator enters weighing mode. 1. Connecting calibration jumper to the 15- pin socket on the indicator back panel. (There is a 15-pin plug in the packing carton with its 14-pin short connected with 15-pin. ) 2. According to table 4-3, carry out calibration step by step. Table 4 - 1 step Operation Display Explanation 1 press [ CALB] after calibration jumper

Summary of the content on the page No. 8

+P X K 3 1 9 0 - A 1 step Operation Display Explanation 8 [ A LoAd1] Loading weight ≥ 5% Max.。 press [ 1 ] [ 5 ] [ d 1500 ] Example: 1500 [ 0 ] [0 ] After stable light is on, press [ Enter ] press [ Enter ] key. 9 press [ Enter ] [ noLoAd ] Confirming zero position again. 10 [ ALoAd2 ] Reloading weight on scale ≥50% Max. It is better that this loading weight is press [2] [0] [ 20000 ] near the F.S. Example: 20000 [0][0] [0] After stable light is on

Summary of the content on the page No. 9

+P X K 3 1 9 0 - A 1 out. 4. . Operating Instructions 4.1 Power on 1 When using AC power , power on , setting the ship- form switch at the back cover of the indicator on “1” ; If using DC power , setting the ship- form switch at the back cover of indicator on “1”, then pressing the recover switch, the indicator will perform “999999 - 000000 ” selfchecking. And then enter weighing mode. Or after pressing any key, self-checking stops and enters weighing mode automaticall

Summary of the content on the page No. 10

+P X K 3 1 9 0 - A 1 (Graph 4-1) Serial Communication port and score display port 4.4 Connecting Scoreboard to Indicator 1. The display interface of scoreboard is 15-pin socket, which has been clearly shown in the Graph 4-1. 2. The scoreboard signal is 20mA continuous current loop, outputting in binary code, the baud rate is 600. 4.5 Connecting Printer to Indicator 1. The print port adopts parallel output and 25-pin connecting socket, which has been clearly shown i

Summary of the content on the page No. 11

+P X K 3 1 9 0 - A 1 ▲ The printer must be compatible to the indicator, please choose the recommended printer. ▲ The printer GND can not be connected to the power GND, otherwise the indicator or printer will be destroyed. 3. Set print parameters step operating display Explanation 1 press [PRN Set ] [ P 00 ] Enter printing setup press [ 9 ] [ 7 ] [ P 97 ] Input password 97 press [ Enter ] 2 [ Auto 1] Auto/ manual print 0: manual 1: Auto press [ 0 ] [ Auto 0 ] Example

Summary of the content on the page No. 12

+P X K 3 1 9 0 - A 1 Press[Enter] [ dct ] 1: use discount End Note: You can use discount only when the blank filling mode is selected. 4. print and print format Press [PRINT] key, you can print required weighing data according to print setting. Record Format: Weight Bill Date 97-01-31 NO. Time Gross ( kg ) Tare ( kg ) Net ( kg ) Accumulating(kg) 0001 08.56.16 299.98 1 298.98 298.98 0002 09.00.09 29

Summary of the content on the page No. 13

+P X K 3 1 9 0 - A 1 REMARK ★ If setting the odE parameter to 1, you can perform the blank filling priting, at this time the other priting formats are invalid (Records format and document format are invalid). Method: pushing [print] key, if dct parameter is set to 1, it will display [BFL **], inputting the discount rate and pushing [Input], it will print out the blank filling report: if dct parameter is set to 0, it will print out the blank filling report directly, ‘discount r

Summary of the content on the page No. 14

+P X K 3 1 9 0 - A 1 communication mode parameters. (2) The sequence of parameters setting as following: Connecting the loadcell , the indicator enters into working mode which is shown in the Graph 2-3. Insert the setting jumper into 15-pin socket at the back of indicator. (There is a 15-pin plug in the packing carton with its 14-pin shorte connected with 15-pin. ). Setup communication parameters as following: Step Operation Display Explanation 1 Press[CALB] Plug in calibration ju

Summary of the content on the page No. 15

+P X K 3 1 9 0 - A 1 [ Enter] key or [weighing] key to exit. If it is incorrect, using digital keys enters new date , then press [ Enter ] key. (2) Under weighing status of the indicator, press [ Time ] key, and Time sign lamp is lighted. Indicator display original Time data at this time. If it is correct, then press [ Enter ] key or the [ weighing ] key to exit. If it is incorrect, using digital keys enters new time data, then press [ Enter ] key. 4.8 Weight data store, check and c

Summary of the content on the page No. 16

+P X K 3 1 9 0 - A 1 3 Clear Press [ clear ] key, can clean accumulating weight value or stored data. Step Operating Display Explanation 1 press [ Clear ] 2 [ sure 0 ] Selecting clear/not clear 0: no 1: yes press [ 1 ] [ sure 1 ] Example: 1 [ sure 1 ] End 4.9 Insufficient voltage indicating When the storage cell voltage is insufficient, the insufficient voltage lamp is on. At this time the indicator will twinkle.You should set the ship-like switch a

Summary of the content on the page No. 17

+P X K 3 1 9 0 - A 1 electronic components will be damaged and electric shock is likely to happen. 5.6 You should cut off power supply of indicator and relevant device before you pull-in and out the connecting line of indicator and external device. ▲ !You must cut off power supply of the indicator , before you plug the connecting line of the loadcell in and out. ▲ !You must cut off power supply of the indicator and the printer, before you plug in connecting line of the printer. ▲ !Yo

Summary of the content on the page No. 18

+P X K 3 1 9 0 - A 1 6.3 Wrong setting information indicating 1 Err 13 Wrong setting of the division value . 2 Err 14 Decimal point must be less than 5, please reset the decimal bit. 3 Err 15 Overload warning must be > 100, please reset it. Err 17 Enter new data which should be less than 65000. 6.4 Wrong connection information indicating 1 Err P It means the printer has trouble or is wrongly connected. push any key to quit. 2 Err 01 It means th

Summary of the content on the page No. 19

+P X K 3 1 9 0 - A 1 3 Err 21 Calibrating data have been lost in RAM and EPROM, Operator must put in the calibration plug, then reenter the original calibration data, turn on the indicator again or re-calibrate it. 4 Err 22 EPROM has been damaged. 5 Err 23 RAM has been damaged. 6.6 Other information indicating 1. Err 24 In normal operation, you must pull off the calibration jumper.The indicator is under normal opera

Summary of the content on the page No. 20

+P X K 3 1 9 0 - A 1 The frame from the computer consists of 6 data explanation 1 02 (X ON) start 2 A ~ Z address 3 A: Shaking hands B: asking GW C: asking tare D: asking NW E: asking accumulated times and accumulated weight 4 XRL checking 5 XRL checking 6 03 (X OFF) end XRL = 2 3 ⊕


Alternative user manuals
# User manual Category Download
1 Epson XK3190-H2B User manual Scale 0
2 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
3 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
4 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
5 A&D FG-150KAL User manual Scale 1
6 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
7 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
8 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
9 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
10 A&D FG-150KBM User manual Scale 0
11 A&D GR Series GR-300 User manual Scale 11
12 A&D GR Series GR-120 User manual Scale 12
13 A&D FG-60KAM User manual Scale 3
14 A&D FS-30Ki User manual Scale 7
15 A&D FG-60KAL User manual Scale 13