IBM R/S Rheometer M/02-212 user manual

User manual for the device IBM R/S Rheometer M/02-212

Device: IBM R/S Rheometer M/02-212
Category: Scale
Manufacturer: IBM
Size: 0.67 MB
Added : 2/11/2014
Number of pages: 65
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for IBM R/S Rheometer M/02-212. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with IBM R/S Rheometer M/02-212.

For your convenience

If looking through the IBM R/S Rheometer M/02-212 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual IBM R/S Rheometer M/02-212 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual IBM R/S Rheometer M/02-212 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
IBM R/S Rheometer M/02-212 User manual - Online PDF
Advertisement
« Page 1 of 65 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual IBM R/S Rheometer M/02-212 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to IBM R/S Rheometer M/02-212. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1


BROOKFIELD R/S RHEOMETER
Operating Instructions
Manual No. M/02-212

Brookfield Engineering Labs., Inc. Page 1 M/02-212

Summary of the content on the page No. 2

Operating Manual for R/S Rheometer Version 1.10 E, valid for firmware version 4.02 All rights reserved, the translation included. Any part of this Operation Manual cannot be reproduced in any form (as printed matter, photocopies, microfilms or in any other form) or processed, copied or disseminated using electronic system without written consent of Brookfield Viscometers Ltd. Brookfield Viscometers Ltd bears no responsibility for any technical or print technical errors or inc

Summary of the content on the page No. 3

CONTENTS I. GENERAL DESCRIPTION 5 I.1 Use of the Rheometer 5 I.2 Measuring Principle 5 II. SYSTEM CONFIGURATION 6 II.1 R/S Rheometer 6 II.2 Measuring Devices 8 II.3 Computer System 8 III. INSTRUMENT INSTALLATION 9 III.1 Stand Mounting 9 III.2 Electrical Connections 10 III.2.1 Temperature Sensor Pt100 10 III.2.2 AC-Adaptor 11 III.2.3 Printer Connection 11 III.2.4 Computer Connection 11 III.3 Mounting of temperature controlled measuring devices 12

Summary of the content on the page No. 4

VI.7 Menu entries of the CONFIGURATION menu 44 VI.7.1 Configuration → Set output mode 44 VI.7.2 Configuration → MeasCount mode 45 VI.7.3 Configuration → Reset meascount 45 VI.7.4 Configuration → Set Time/Date 45 VI.7.5 Configuration → Set RS232 Parameter 46 VI.7.6 Configuration → Language 47 VI.7.7 Configuration → Service, Service 2 47 VI.8 Serial Data transfer via Interface RS232 47 VII. MEASUREMENTS 50 VII.1 Measuring in manual mode 50 VII.2 Measuring

Summary of the content on the page No. 5

I. General Description In this chapter you get general information concerning use and measurement principle of your R/S Rheometer. I.1 Use of the Rheometer The R/S Rheometer system provides possibility of Newtonian fluids viscosity measurements, recording of flow curves as well as determination of viscosity functions of non-Newtonian fluids in steady shear flows. Furthermore, it assures carrying out of measurements in non-stationary shear flows and the measurements of viscoelast

Summary of the content on the page No. 6

II. System Configuration In this chapter you get information concerning system configuration, temperature control device, optional computer system and data- and signal flow of your Rheometer system. The Rheometer system R/S Rheometer consists of: - electronic unit with measuring drive integrated in one housing - stand with working surface - AC-adaptor as accessories are supplied: • printer • coaxial cylinder measuring system (see Appendix A) • temperature measuring sensor P

Summary of the content on the page No. 7

R/S Rheometer main instrument (minimum configuration) 14 BROOKFIELD 1 Main-Menue - Run Single - Run Program - Remote Power S T O K 4 6 5 2 3 7 13 10 12 11 8 9 1 R/S Rheometer 2 Measuring bob coupling 3 Mounting flange 4 Pt100-clamp fixture (accessory) 5 Pt100 (accessory) 6 Standard measuring bob (accessory) 7 Standard measuring cup (accessory) 8 Measuring cup bottom, or thread protection (accessory) 9 Measuring cup screw fitting 10 Stand 11 AC-a

Summary of the content on the page No. 8

II.2 Measuring Devices Measuring devices are not included in the main delivery volume of R/S Rheometer and must be ordered in accordance with your measuring requirements. As measuring devices are optional supplied: • coaxial standard measuring systems for R/S Rheometer (see Appendix A) with and without built-in temperature sensor Pt100 • temperature control device “FTK-CC“ for use of cylinder measuring system in temperature range -10°C ... +90°C • cooling device “KE“ for use of c

Summary of the content on the page No. 9

III. Instrument Installation In this chapter you will know how to prepare your R/S Rheometer for the first measurements. You will know particularly, - how to mount the R/S Rheometer, - details about the electric connections - installation of accessories such as temperature control device, cooling device, measuring system - hose connections. III.1 Stand Mounting The stand consists of: - the stand base plate - the stand column with Rheometer - the shelf Hex-nut wrench

Summary of the content on the page No. 10

III.2 Electrical Connections Connections for the electrical components of the R/S Rheometer are located at the instrument back side: Socket “Centronics“ Centronics parallel Printer interface RS232 Socket “RS232“ Pt 100 Power DC serial communication port Socket “Pt100“ for temperature sensor Socket “DC“ for AC- adaptor connection Mains switch “POWER“ Any cables from and to R/S Rheometer can be connected or disconnected only when instrument is switched off! III.2.1 Te

Summary of the content on the page No. 11

III.2.2 AC-Adaptor The AC adaptor supplies R/S Rheometer with power. Only the AC-adaptor delivered by BROOKFIELD with your Rheometer may be used for power supply of R/S Rheometer. The AC-adaptor may be inserted to the socket with corresponding grounding only. Connect the AC adaptor only using the plug in a proper way grounded to avoid electric shocks or damage of the system components. Pay attention also to “Requirements to the mains cable” (see Appendix). Connecting the AC-ad

Summary of the content on the page No. 12

Please read information concerning installation of the computer system in this Operation Manual. III.3 Mounting of temperature controlled measuring devices In this chapter you get information concerning mounting and attachment of the following accessories components: • FTK-CC temperature control device for use of cylinder measuring system in the temperature range -10°C...+90°C (liquid’s temperature control) • KE cooling device in conjunction with FTK-CC temperature control device or ME

Summary of the content on the page No. 13

BROOKFIELD Main-Menue - Run Single - Run Program - Remote Power ST OK Cooling device KE Temperature control device FTK-CC Built in Pt100 Temperature control liquid from / to thermostatic device Connecting cable Pt100 Fig. 5.: Operation with FTK-CC and cooling device KE Thermostat connection to temperature control device FTK-CC Hoses’ connections are necessary to join a liquid circulation thermostat by operation of the R/S Rheometer with liquid circulation temperature control dev

Summary of the content on the page No. 14

-20 °C to +250 °C thermostat oil Thermostatic fluids can be ordered from BROOKFIELD. During measurements in the temperature range below -10°C and above +90°C the temperature control device “FTK-CC” may be put into operation only if the cooling liquid flows through the “KE” in order to prevent overheat of the measuring sensor. III.3.2 Mounting of the measuring device ME-CP/PP - Turn off the R/S Rheometer with the mains switch “POWER” at the instrument back side. - When using

Summary of the content on the page No. 15

During measurements in the temperature range below -10°C and above +90°C the measuring device “ME-CP/PP” may be put into operation only if the cooling liquid flows through the “KE” in order to prevent overheat of the measuring sensor. Brookfield Engineering Labs., Inc. Page 15 M/02-212

Summary of the content on the page No. 16

Measuring device for cone/plate and plate/plate measuring systems ME CC/CP Brookfield Engineering Labs., Inc. Page 16 M/02-212

Summary of the content on the page No. 17

III.3.3 Mounting of the cooling device KE The optionally supplied cooling device “KE” must be used in case of the R/S Rheometer operation with the liquid temperature control device “FTK-CC” or measuring device “ME-CP/PP“ in the temperature range below -10°C and above +90°C. When using cooling device KE temperature range of temperature control device “FTK-CC“ and measuring device “ME-CP/PP“ is expanded to -20°C... +180°C. The cooling liquid flows through the cooling channel of the coo

Summary of the content on the page No. 18

IV. Environment, handling, cleaning and maintenance In this chapter you get information concerning environment, handling, cleaning and maintenance of your R/S Rheometer. IV.1 Operating environment, Storage Find comfortable, convenient working place where you install your R/S Rheometer. It must be enough room for installation of the stand, measuring system, measuring substances and peripheral devices (for example printer, computer and thermostat). You need a grounded socket for

Summary of the content on the page No. 19

Check that any liquid does not penetrate into the housing (e.g. through the instrument connecting plugs) and into the bearings of the measuring drive. It results in the instrument damage! IV.4 Maintenance The R/S Rheometer is designed for long-term operation. Nevertheless we recommend a regular maintenance in one-year cycle by a service engineer of BROOKFIELD or of corresponding representation. Works on control electronics, all accessories, measuring drive as well as with

Summary of the content on the page No. 20

V. Measuring Systems In this chapter you get information concerning use of the measuring system. At present the following measuring system types are supplied: a) Standard measuring systems MS-CC48...CC8 DIN/RC and DG-DIN/RC for measurement without temperature control device FTK-CC consists of: - measuring cup for R/S Rheometer (MB-CC48...MB-CC8/RC and MB-DG/RC) depending on measuring-system - measuring cup bottom - measuring bob (MK-CC48...CC8/RC and MK-DG/RC) depending on measur


Alternative user manuals
# User manual Category Download
1 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
2 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
3 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
4 A&D FG-150KAL User manual Scale 1
5 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2
6 A&D Ej Series Compact Balance EJ-4100 User manual Scale 5
7 A&D Ej Series Compact Balance EJ-120 User manual Scale 2
8 A&D Ej Series Compact Balance EJ-6100 User manual Scale 5
9 A&D FG-150KBM User manual Scale 0
10 A&D GR Series GR-300 User manual Scale 11
11 A&D GR Series GR-120 User manual Scale 12
12 A&D FG-60KAM User manual Scale 3
13 A&D FS-30Ki User manual Scale 7
14 A&D FG-60KAL User manual Scale 13
15 A&D HC-30Ki User manual Scale 12