Taylor TE30WD user manual

User manual for the device Taylor TE30WD

Device: Taylor TE30WD
Category: Scale
Manufacturer: Taylor
Size: 0.83 MB
Added : 9/11/2013
Number of pages: 15
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Taylor TE30WD. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Taylor TE30WD.

For your convenience

If looking through the Taylor TE30WD user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Taylor TE30WD on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Taylor TE30WD to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Taylor TE30WD User manual - Online PDF
Advertisement
« Page 1 of 15 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Taylor TE30WD but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Taylor TE30WD. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1
















TE30WD


Wireless Scale


INSTRUCTION MANUAL



Summary of the content on the page No. 2

TABLE OF CONTENTS: TABLE OF CONTENTS ................................................................................................................... 1 SPECIFICATIONS .......................................................................................................................... 2 DISPLAY ........................................................................................................................................... 3 BUTTON DESCRIPTION ............................

Summary of the content on the page No. 3

SPECIFICATIONS Model TE30WD 0-10 lb x 0.05 oz/10-30 lb x 0.1 oz Capacity 0-5 kg x 0.002 kg(2 g)/5-15 kg x 0.005 kg (5 g) 30 lb x 1/8 oz Weight Unit lb:oz(decimals)/lb:oz(fractions)/kg LCD Readout 1” LCD readout Dimensions 14” x 14” x 1.6” Buttons ON/OFF, HOLD, Unit, Tare, Channel  10-AA batteries(6 for base,4 for remote, not Power included.) Supply  2 120V AC adapters 1 for base, 1 for remote (included) Operation 32 °F / 104 °F (0 ℃ / 40 ℃) Temperature 2

Summary of the content on the page No. 4

DISPLAY BUTTON DESCRIPTION Press to turn the scale ON or OFF. Press to ‘Tare’ (zero) the weight of any item while weighing. Press to ‘Hold’ the weight on the screen. Press to switch between lb:oz and kg units of measurement. Press to reset the scale to zero(TARE function)if the scale does not show zero automatically. Icon flashes when scale is ready for a weighing. Stability display: If the display shows‘o’,the weight is stable on the scale. If t

Summary of the content on the page No. 5

PREPARING SCALE FOR WEIGHING Before Weighing 1. Please select the scale’s channel to match the wireless display. (The scale’s channel indicator is located on the scale’s base; please remove the rubber stopper to access the channel indicator.)For example: If the wireless display is using Channel-1, select Channel-1 for the scale.(Please see Page 6 for instructions for selecting platform channels.) 2. Press the ON/OFF button to turn on the scale. 3. Please make sure that the distance bet

Summary of the content on the page No. 6

CHANGING THE WIRELESS DISPLAY’S CHANNEL Press the button to select the wireless display channel. Channel numbers (1, 2, 3) are shown on the left hand side of the display. When a channel is selected,a triange icon points to the selected channel. For example- If Channel-1 is selected, the triange icon points to ‘1’. Channel 1 Channel 2 Channel 3 5

Summary of the content on the page No. 7

SELECTING THE SCALE PLATFORM’S CHANNEL To select the scale platform’s channel, first turn off the scale base and wireless display units. Then use the dip switch, which is located on the bottom of the scale under the rubber stopper. The dip switch has four pins marked ‘1, 2, 3, 4’ (Pin-4 is not active; only 3 channels are available for use.) To select a channel, move the pin toward the ‘ON’ mark (pictured below). For example- To select Channel-1 for the scale, move Pin-1 towards the ‘ON’

Summary of the content on the page No. 8

USING THE TARE FUNCTION The Tare Function allows the user to zero the scale to cancel out the weight of a container, thus giving the weight of the item being weighed.  Press the ON/OFF button to turn on the scale.  Place the containter on the scale platform.  Press the ‘TARE’ button after the weight stabilizes and stable sign displays.  The display will reset to ‘0’.  Place the item to be weighed on the platform(without removing the ‘tared’ container). OR Touch Free Tare Func

Summary of the content on the page No. 9

ACTIVATING/ DEACTIVATING TOUCH LESS TARE FEATURE Press to move right or down as shown in setup flowchart. The start icon(*) is the default value FUNCTION SETTINGS Function Description Default (Units): lb , kg lb (Auto off Time): 120 sec/ 180 sec/ 240 sec/ 300 sec/ OFF (Hold range): 2d/ 5d/ 10d/ 15d (Touch less feature): on , off To confirm the settings and end the procedure 8

Summary of the content on the page No. 10

TABLE-TOP STAND AND WALL MOUNTS You may stand the scale platform on a table. Adjust the angle of the wireless display for easy viewing. Table top display: Wall display: The wireless display may be mounted to a wall. Use the mounting material included. 1. Screw the screws to the wall as shown. 2. Push the wireless display onto the well. 9

Summary of the content on the page No. 11

POWER SOURCES If displays on the LCD, please use the included Taylor adapters or replace the batteries. Insert an adapter into the bottom of the wireless display and the scale base. Indicator - AC Jack Connector Weighing Platform- AC Jack Connector This scale’s weighing platform and wireless dislay require separate electric power. Before using the scale, please make sure that both the scale base and wireless dis

Summary of the content on the page No. 12

ERROR MESSAGES Message Description Low battery indicator for wireless display: This warning indicates the batteries for the wireless display are low. Please replace all the batteries or use the AC adapter for operation. Low battery indicator for scale base: This warning indicates the batteries for the scale base are low. Please replace all batteries or use the AC adapter for operation. EEPROM error for wireless display: The programming for the wireless display has an err

Summary of the content on the page No. 13

FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENT Transmission Collision Signals from other household devices, such as doorbells, home security systems and entry controls, may interfere. This is normal and does not affect the general performance of this product. The transmission will resume once the interference recedes. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are desi

Summary of the content on the page No. 14

Precautions This scale is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: 1. Always read instructions thoroughly to ensure that you have the full benefit of all the unit's features. 2. DO NOT immerse units in water, as doing so will cause damage to internal components and void the warranty. If you spill liquid on it, dry it immediately with a soft, lint-free cloth. 3. DO NOT clean the units with an abrasive or corrosive mat

Summary of the content on the page No. 15

One Year Limited Warranty Taylor warrants this product to be free from defects in materials or workmanship for one (1) year from date of original purchase. It does not cover damages or wear resulting from accident, misuse, abuse, commercial use, or unauthorized adjustment and/or repair. If service is required, do not return to distributor. For service, call between 7:30 AM and 4:30 PM, Mountain Standard Time, Monday through Friday. To assist us in servicing you, please have the m


Alternative user manuals
# User manual Category Download
1 Taylor 2020 User manual Scale 4
2 Taylor 3710 User manual Scale 1
3 Taylor 3701 User manual Scale 1
4 Taylor 3724-21 User manual Scale 1
5 Taylor 3720 User manual Scale 6
6 Taylor 2372 User manual Scale 2
7 Taylor 3700-44 User manual Scale 1
8 Taylor 3801 User manual Scale 8
9 Taylor 3700 User manual Scale 0
10 Taylor 3852 User manual Scale 1
11 Taylor 7006EXP User manual Scale 1
12 Taylor 4827 User manual Scale 1
13 Taylor 5594 User manual Scale 1
14 Taylor 5742 User manual Scale 2
15 Taylor 6150 User manual Scale 1
16 A&D Ej Series Compact Balance EJ-1500 User manual Scale 17
17 A&D A & D Analytical Balance GH-120/GH-200/GH-300/GH-202/GH-252 User manual Scale 13
18 A&D Ej Series Compact Balance EJ-440 User manual Scale 0
19 A&D FG-150KAL User manual Scale 1
20 A&D Ej Series Compact Balance EJ-2000 User manual Scale 2