Omega 26 user manual

User manual for the device Omega 26

Device: Omega 26
Category: Thermometer
Manufacturer: Omega
Size: 0.68 MB
Added : 6/16/2014
Number of pages: 48
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Omega 26. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Omega 26.

For your convenience

If looking through the Omega 26 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Omega 26 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Omega 26 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Omega 26 User manual - Online PDF
Advertisement
« Page 1 of 48 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Omega 26 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Omega 26. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Need for
Control?
UserÕs Guide
Panels & Assemblies
®
http://www.omega.com
e-mail: info@omega.com
CL23A, 24, 25, 26, 27
Digital Calibrator/Thermometer

Summary of the content on the page No. 2

TM omega.com ® OMEGA SM OMEGAnet On-Line Service Internet e-mail http://www.omega.com info@omega.com Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: canada@omega.com For immediate technical or application assistance: SM USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGA SM Customer S

Summary of the content on the page No. 3

TABLE OF CONTENTS General Information......................................................................... 2 Common Specifications................................................................... 2 Unique Specifications...................................................................... 5 Features........................................................................................... 6 Manual Addenda ............................................................................. 6 Unpac

Summary of the content on the page No. 4

GENERAL INFORMATION This manual provides operating instructions and maintenance information for five temperature instruments. These instruments are high performance cali- brator-thermometers capable of simulating and measuring a wide-variety of sensors. In addition, features such as data storage and ramping further enhance their versatility. It is recommended that you read this manual thoroughly, especially the sec- tions on safety, prior to operating these instruments. COMMON SPECIFICATIONS THE

Summary of the content on the page No. 5

RTD; ±0.2°F (rdg ‡ – 50°F) RTD; ±0.5°F (rdg < – 50°F) RTD; ±0.2°F ±0.04% rdg (meter mode) THERMISTOR; ±0.5F OHMS; ±0.02% range * Exclusive of sensor errors, and lead resistance induced errors. RESOLUTION: TEMPERATURE; 0.1°/1° F/C RESOLUTION: OHMS; 0.01Ω/0.1Ω/1Ω REPEATABILITY (1 week at constant ambient temperature): K, J, T, E, N; ±0.2°F typ. B, R, S, G, C, D; ±1.0°F typ. RTD, THERMISTOR; ±0.1°F typ. OHMS; ±0.01% rng typ. TEMPERATURE COEFFICIENT: From 18°C to 28°C, included in accuracy specifica

Summary of the content on the page No. 6

KEYPAD: 12 momentary switches with tactile feedback select; • On/Off • Change/Enter • Clear/–0 • Sensor Select/1 • °F/°C/2 • Resolution/3 • Operate/4 • Store/5 • Recall/6 • Calibrator/Meter/Up Ramp/7 • Calibrator Step/Down Ramp/8 • Calibrator Ramp/Meter Hold/9 DISPLAY: 5 digit LCD, 0.4" height, and decimal point. Annunciators; • Loaded Memory Locations (10 for data storage, 4 for ramp parameters) • Low Battery (BAT) • Number Change Mode (NUM) • Calibrator Mode (CALIB) • Meter Mode (METER) • Oper

Summary of the content on the page No. 7

BATTERY LIFE, CONTINUOUS: 10 hrs. typical, alkaline; 3 hrs typical, Ni-Cd (rechargeable). BATTERY INDICATOR: Display indicates BAT when less than 10% of life remains. DIMENSIONS, WEIGHT: 7.0" · 2.9 · 1.1". Net weight 12 oz. UNIQUE SPECIFICATIONS NOTE: The specifications below are specific to the model(s) as identified by model number. The difference specifications are in addition to the OVERALL SERIES SPEC- IFICATIONS found on pages 2-5. • MODEL CL23A/CL23EC: SENSOR SELECTION: K, J, T/K, J, T, L

Summary of the content on the page No. 8

ACCURACY: (18°C to 28°C ambient, 2 years): ±0.5 °F (rdg ‡ –50°F). ±0.04% rdg (rdg > 1250°F) ±1.0°F (rdg < –50°F) OHMS; ±0.04% range TEMPERATURE COEFFICIENT: 18°C to 28°C; included in accuracy specifications. From 0°C to 18°C, and 28°C to 50°C. K, J, T, E; ±(0.006% rdg + 0.03°C)/°C RTD, THERMISTOR, OHMS; ±(0.006% rdg +0.012% rng)/°C RAMP FUNCTION: Not Included. • MODEL CL27/CL27EC: SENSOR SELECTION: K, J, T, E, N, B, R, S, G, C, D/K, J, T, E, N, B, R, S, L, C, D Thermocouples 100Ω/1000Ω Platinum

Summary of the content on the page No. 9

UNPACKING YOUR UNIT Remove the Packing List and verify that you have received all equipment. If you have any questions about the shipment, please call the OMEGA Customer Service Department at 1-800-622-2378 or (203) 359-1660. When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent. NOTE: The carrier will not honor any claims unless all shipping material is saved

Summary of the content on the page No. 10

WARNING Do not touch a temperature probe sheath when measuring excessively high or low temperatures, or toxic substances. WARNING Do not attempt to measure temperatures beyond the range of the probe being used. Probe damage or personal injury could result from exceeding a probe's maximum temperature rating. WARNING The American National Safety Institute (ANSI) states that a shock hazard exists when probes or sensors are exposed to voltage levels greater than 42VDC or 42V peak AC. Do not use this

Summary of the content on the page No. 11

CAUTION Keep inputs electrically isolated from outputs. Do not con- nect an external voltage source between the two connectors, and avoid any external electrical pathways between input and output (T2 & T1). Failure to do so will disturb meter readings and calibrator output levels. Damage to the instrument is also possible. Where the meter and calibrator connectors are simultane- ously wired into a system lacking the above isolation, it is necessary to use an "ungrounded" (i.e. electrically isola

Summary of the content on the page No. 12

2. Remove the old battery by lifting the battery extractor loop. 3. Place the new battery in the battery compartment. Be sure to observe proper polarity. 4. Re-install the battery cover before resuming use of the instrument. NOTES: • Less than 10% of battery life remains when the BAT annuncia- tor turns on. • When the battery is excessively discharged, the display is blanked. • If the instrument is going to be stored for a long period of time or in a high temperature environment, remove the bat

Summary of the content on the page No. 13

OPERATING INSTRUCTIONS 1. DIAGNOSTICS AND ERROR MESSAGES Unit self-diagnostics provide fault condition readouts which are described below: PROBLEM: LIKELY CAUSE: Blank display, unit does not (1) Improper battery installation. power-up. (1) Check battery polarity. (2) Dead battery. BAT Annunciator. (1) Low battery voltage, install a new battery. If problem persists, con- sult factory. Display reads OPEN. (1) No thermocouple, RTD or thermis- tor is plugged into the meter input. Display reads E1 mo

Summary of the content on the page No. 14

Figure 2. Keypad Figure 3. Display Test If the unit is turning on for the first time after a new battery is installed, it will automatically default to the METER mode (ie. temperature measurement operation). It also defaults to K-type thermocouples, and °F readings with 0.1° resolution. The corresponding LCD annunciators are enabled: 12

Summary of the content on the page No. 15

METER: (unit functioning as a thermometer) K: (K-type thermocouple) °F: (Fahrenheit readings) OPR: (Instrument is operational) If no input thermocouple is connected to the unit at this time, the numeric segments will indicate "OPEN". Plugging a thermocouple into the meter jack (connector T2, on the top right side) will give actual thermocouple temperature readings. NOTE: To obtain full accuracy, allow 1-2 minutes after connect- ing a thermocouple plug, for thermal setting. If the instrument is t

Summary of the content on the page No. 16

6. Select display resolution with 0.1°/1° key. NOTE: Set-up is retained during power-off. Hold: Meter readings can be put on hold at any time by depressing the HOLD key. At this time, the HOLD annunciator turns on, the reading is frozen, and all keys (except ON/OFF and HOLD) are locked out. Depress the HOLD key again to return to real-time readings, and re-enable the keypad. 4. METER MODE OPERATION (RTD, Thermistor & Ohms) Set-Up: 1. Connect a sensor or unknown resistance to the instrument as sh

Summary of the content on the page No. 17

WHT BLK GRN RED Figure 6. 4-Wire Resistance Measurement Lead resistance errors are compensated for in 3-wire configurations. However full compensation requires equal resistance in each lead. This configuration is common with 100-ohm RTDs. In 4-wire configurations, accuracy is unaffected by lead resistance, and resistance differences between leads. NOTE: These instruments measure input voltages on all 4 termi- nals, and are able to distinguish between 2-4 and 3-wire hookups. Switching between the

Summary of the content on the page No. 18

To Save Readings: 1. While in the METER OPR mode, depress the STORE key. Note that the OPR annunciator is replaced by STO. 2. Next depress one of the memory location numbers (keys 0, 1, . . ., 9). The corresponding memory annunciator turns on and the meter returns momentarily to the OPR mode, displaying thermocouple temperature. eg. STORE 7 NOTES: • The enabled location annunciator indicates that the meter read- ing at the instant that the location number key was hit, was stored in memory. • Whe

Summary of the content on the page No. 19

eg. RECALL 3 eg. RECALL 5 eg. RECALL 2 eg. etc. 4. To return the meter to the operate mode, depress OPR after recalling the last reading. All active location annunciators will turn on again, together with the OPR annunciator. NOTE: Recalling data from unused (ie, empty) locations will give a zero reading. To Erase Data Locations (Meter Mode): 1. Individual data locations can be erased by recalling the location to be cleared, followed by a CLEAR key input. Note that the annunciator for the cleare

Summary of the content on the page No. 20

6. Select the resolution desired (0.1°/1° key). NOTE: With 1° resolution, one less key stroke will be required to enter calibrator output temperatures via the keypad. 7. The unit accepts numeric inputs by first changing the keypad to its num- ber-entry mode (NUM) by depressing the CHANGE/ENTER key once. The numeric display will flash, the OPR annunciator will turn off, and the NUM annunciator will turn on. Key in desired temperature value, most sig- nificant digit first. After the desired temper


Alternative user manuals
# User manual Category Download
1 Omega 25 User manual Thermometer 1
2 Omega A12P User manual Thermometer 0
3 Omega CL24 User manual Thermometer 4
4 Omega CL25 User manual Thermometer 5
5 Omega 27 User manual Thermometer 0
6 Omega CL27 User manual Thermometer 6
7 Omega CL23A User manual Thermometer 30
8 Omega CL26 User manual Thermometer 4
9 Omega CL3512A User manual Thermometer 19
10 Omega DP1001M User manual Thermometer 0
11 Omega DP751 User manual Thermometer 0
12 Omega DP119-RTD User manual Thermometer 0
13 Omega DPG110/120 User manual Thermometer 1
14 Omega HH370 User manual Thermometer 1
15 Omega HH501DK User manual Thermometer 0
16 A&D DT-103 User manual Thermometer 40
17 A&D DT-102 User manual Thermometer 24
18 A&D UT-302 User manual Thermometer 15
19 Acu-Rite 416 User manual Thermometer 7
20 Acu-Rite #00609SBDIA1 User manual Thermometer 3