Carrier user manual

User manual for the device Carrier

Device: Carrier
Category: Thermostat
Manufacturer: Carrier
Size: 0.14 MB
Added : 11/27/2013
Number of pages: 16
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Carrier . Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Carrier .

For your convenience

If looking through the Carrier user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Carrier on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Carrier to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Carrier User manual - Online PDF
Advertisement
« Page 1 of 16 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Carrier but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Carrier . If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Programmable Thermostats
Visit www.carrier.com
Installation, Start-Up, and Operating Instructions
NOTE: Read the entire instruction manual before starting the
installation.
As an ENERGY STAR Partner, Carrier Corporation has
determined that this product meets the ENERGY STAR
This symbol → indicates a change since the last issue.
guidelines for energy efficiency.
INDEX
Page
SAFETY CONSIDERATIONS .....................................................1
INTRODUCTION....................................

Summary of the content on the page No. 2

• Close to or in a frequently used room, preferably on an inside → Switch D - Intelligent Heat Staging Select partitioning wall. (Active on 2S models only) • On a section of wall without pipes or duct work. This switch converts a 2-speed heat pump thermostat with 1 stage Thermostat should NOT be mounted: of auxiliary heat into a 1-speed heat pump thermostat with 3 stages of auxiliary heat for comfortable leaving air temperature. It • Close to a window, on an outside wall, or next to a door leadi

Summary of the content on the page No. 3

→ Table 1—Model Selection and Wiring Diagram Chart AIR CONDITIONER HEAT PUMP INDOOR UNIT 1 Speed 2 Speed 1 Speed 2 Speed 1-Stage Model AC Model 2S Requires Dual Fuel Ther- Model 2S Furnace See Fig. 2 See Fig. 8 mostat See Fig. 11 2-Stage Model AC Model HP Model 2S Requires Dual Fuel Ther- Model 2S Furnace See Fig. 3 See Fig. 4 See Fig. 9 mostat See Fig. 12 Model AC Model HP Model 2S Model HP Model 2S Typical Fan Coil See Fig. 5 See Fig. 6 See Fig. 10 See Fig. 7 See Fig. 13 Variable-Speed Model A

Summary of the content on the page No. 4

4. Press SET TIME/TEMP button again to flash upper small higher or lower value. The selected number is number of degrees, display for selection of another option, or press END to exit plus or minus, which will be added to actual temperature. The configuration mode. numbers can range between -5 and +5. Factory default is 0. This adjusted value will be used as actual temperature for both display Option 3—Fahrenheit or Celsius Operation and control action. For example, if 2 is selected, 72°F actual

Summary of the content on the page No. 5

stay on and turn Cool Stage 1 on. For actual outputs, refer to Table TO TEST EMERGENCY HEAT (heat pump systems only): 2, making sure the correct row from the table is selected. To turn To test, press MODE button until EHEAT icon turns on. This will off, raise cooling set point above the room temperature. Cool Stage allow operation of auxiliary heat only. Raising set point above 1 and the triangle will turn off within a few seconds. room temperature will turn on the first stage of auxiliary heati

Summary of the content on the page No. 6

6 → Table 2—Programmable Thermostat Quick Reference THERMOSTAT OUTPUT AC/HP Staging 24v Heat Heat Cool TSTAT Model Outdoor Unit Configuration Configuration Common Fan Heat Stage 3 Heat Stage 4 Cool Stage 1 Reversing Valve Hot Stage 1 Stage 2 Stage 2 (Switch C) (Switch D) AC01-B AC EITHER EITHER R C G W/W1 N/A N/A N/A Y/Y2 N/A N/A HP01-B HP OFF EITHER R C G Y/Y2 W/W1 N/A N/A Y/Y2 N/A O/W2 W/W1 HP01-B AC ON EITHER R C G O/W2 N/A N/A Y/Y2 N/A N/A W/W1 2S01-B 2-Speed AC ON EITHER R C G O/W2 N/A N/A

Summary of the content on the page No. 7

MODEL AC SINGLE-STAGE SINGLE-SPEED THERMOSTAT FURNACE AIR CONDITIONER 24 VAC HOT R R FAN G G HEAT STAGE 1 W/W1 W COOL STAGE 1 Y/Y2 Y Y N/A O/W2 N/A Y1/W2 24 VAC COMM C C C N/A B S1 OUTDOOR SENSOR S2 CONNECTION See note 1 ON SUGGESTED DIP SWITCH SETTINGS AB C D OFF OFF OFF OFF A98485 → Fig. 2—Single-Speed Air Conditioner with Single-Stage Furnace—Model AC Thermostat TWO-STAGE OR MODEL HP VARIABLE-SPEED SINGLE-SPEED TWO-STAGE OR MODEL AC SINGLE-SPEED THERMOSTAT FURNACE AIR CONDITIONER VARIABLE-SP

Summary of the content on the page No. 8

MODEL HP TYPICAL SINGLE-SPEED THERMOSTAT FAN COIL AIR CONDITIONER MODEL AC TYPICAL SINGLE-SPEED THERMOSTAT FAN COIL AIR CONDITIONER 24 VAC HOT R R 24 VAC HOT R R FAN G G FAN G G HEAT STAGE 1 W/W1 W2 * COOL STAGE 1 Y Y * Y/Y2 COOL STAGE 1 Y/Y2 Y Y HEAT STAGE 1 W2 W/W1 HEAT STAGE 2 O/W2 W3 N/A O/W2 W3 N/A Y1/W2 E E N/A Y1/W2 24 VAC COMM C C C 24 VAC COMM C C C N/A B N/A B OUTDOOR S1 OUTDOOR S1 SENSOR SENSOR See notes 2, 7, and 8 See notes 1, 7, and 8 S2 CONNECTION CONNECTION S2 ON ON SUGGESTED D

Summary of the content on the page No. 9

MODEL 2S TYPICAL TWO-SPEED MODEL 2S TWO-STAGE OR TWO-SPEED THERMOSTAT FAN COIL AIR CONDITIONER THERMOSTAT VARIABLE-SPEED AIR CONDITIONER FURNACE 24 VAC HOT R R R * COOL STAGE 1 Y1/W2 Y1 Y1 FAN G G FAN G G HEAT STAGE 1 W/W1 W2 W/W1 HEAT STAGE 1 W/W1 * COOL STAGE 2 Y/Y2 Y Y2 COOL STAGE 2 Y/Y2 Y2 Y/Y2 HEAT STAGE 2 O/W2 W3 HEAT STAGE 2 O/W2 W2 E COOL STAGE 1 Y1/W2 24 VAC HOT R R R Y1 24 VAC COMM C C C 24 VAC COMM C C C N/A B HUM N/A B S1 OUTDOOR OUTDOOR S1 SENSOR SENSOR S2 CONNECTION CONNECTION S2 S

Summary of the content on the page No. 10

MODEL 2S SINGLE-SPEED THERMOSTAT EASY SELECT HEAT PUMP TERMINAL BOARD DH J1 MODEL 2S TYPICAL TWO-SPEED JUMPER THERMOSTAT FAN COIL HEAT PUMP 24 VAC HOT R R R 24 VAC HOT R R FAN G G R FAN G G COOL/HEAT Y/Y2 Y/Y2 Y STAGE 1 REMOVE HEAT STAGE 3 W/W1 W2 HEAT STAGE 2 W/W1 W1 W2 J2 JUMPER FOR HEAT W3 STAGING COOL/HEAT Y/Y2 HEAT STAGE 3 Y1/W2 W2 W2 STAGE 2 Y2 E RVS COOLING O/W2 RVS COOLING O/W2 O O O * Y COOL/HEAT Y1/W2 Y1 STAGE 1 Y1 24 VAC COMM C C C W3 24 VAC COMM C C N/A B C N/A B OUTDOOR S1 See notes

Summary of the content on the page No. 11

MODEL 2S TWO-SPEED THERMOSTAT EASY SELECT HEAT PUMP MODEL 2S TWO-SPEED TERMINAL BLOCK THERMOSTAT EASY SELECT AIR CONDITIONER TERMINAL BOARD DH J1 JUMPER DH J1 24 VAC HOT R R R JUMPER 24 VAC HOT R R R FAN G G FAN G G COOL/HEAT Y1/W2 Y1 Y1 STAGE 1 COOL STAGE 1 Y1/W2 Y1 Y1 RVS COOLING O/W2 O O COOL STAGE 2 Y/Y2 Y/Y2 Y2 COOL/HEAT Y/Y2 Y/Y2 Y2 STAGE 2 REMOVE HEAT STAGE 1 W/W1 W1 J2 JUMPER FOR HEAT HEAT STAGE 3 W/W1 W1 W2 STAGING J2 JUMPER HEAT STAGE 2 O/W2 W2 W2 W3 O 24 VAC COMM C C C 24 VAC COMM C

Summary of the content on the page No. 12

SPLICE HEATER MODEL HP BOX CONTROL BOX SPLICE HEATER THERMOSTAT MODEL HP BOX CONTROL BOX THERMOSTAT YEL COOL STAGE 1 Y/Y2 YEL COOL/HEAT Y/Y2 STAGE 1 GRN FAN G ORN RVS COOLING O/W2 WHT HEAT STAGE 1 W/W1 WHT N/A Y1/W2 RED (TRAN) N/A Y1/W2 PNK WHT W/W1 HEAT STAGE 2 WHT VIO O/W2 HEAT STAGE 2 GRN FAN G RED 24 VAC HOT R RED RED 24 VAC HOT R BRN 24 VAC COMM C BRN BRN 24 VAC COMM C BRN N/A B N/A B OUTDOOR S1 See notes 2, 10, 11, and 12 OUTDOOR S1 SENSOR See notes 3, 11, and 12 SENSOR CONNECTION S2 CONNE

Summary of the content on the page No. 13

→ WIRING DIAGRAM NOTES 1. The AC model thermostat can only control 1-stage cool and 1-stage heat. Dip Switch-C on has no controlling function and can either be ON or OFF. 2. HP and 2S model thermostat MUST have Dip Switch-C ON when installed in air conditioner applications. If required, second-stage heat is controlled by O/W2. Refer to indoor equipment Installation Instructions for proper setup. 3. HP and 2S model thermostat MUST have Dip Switch-C OFF when installed in heat pump applications. Th

Summary of the content on the page No. 14

→ OPERATIONAL INFORMATION Five-minute Compressor Timeguard This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the FAN mode button and the INCREASE TEMPERATURE button. Fifteen-minute Cycle Timer This timer prevents the start of a heating or cooling cycle until at least 15 minutes after the last start of the same cycle. Its function is to assure that equipment is not cycled more than 4 times per

Summary of the content on the page No. 15

PROGRAMMABLE THERMOSTAT CONFIGURATION RECORD Date Owner/Operator Thermostat Model No. A) Hardware Configuration Switch A Zoning Selection. (OFF = Disable, ON = Enable) Switch B Smart Recovery. (OFF = Enable, ON = Disable) Switch C Heat Pump Operation. (OFF = Enable, ON = Disable) Switch D Intelligent Heat Staging. (OFF = Disable, ON = Enable) B) Mode Settings Hold (On or Off) Mode (Off, Heat, Cool, Auto, Eheat) Heating Set Point Value Cooling Set Point Value Fan (Auto or On

Summary of the content on the page No. 16

SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including: • Unit Familiarization • Maintenance • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book. Classroom Service Training plus "hands-on" the products in our labs can mean


Alternative user manuals
# User manual Category Download
1 Carrier User manual Air Conditioner 37
2 Carrier 33CS250-01 User manual Thermostat 319
3 Carrier 33CSIRRCVR-01 User manual Thermostat 60
4 Carrier 53DFS250-FS User manual Thermostat 43
5 Carrier 33CS450-01 User manual Thermostat 118
6 Carrier 33CS250-FS User manual Thermostat 21
7 Carrier 33CS400-01 User manual Thermostat 76
8 Carrier 48/50TF User manual Thermostat 20
9 Carrier 48/50TJ User manual Thermostat 26
10 Carrier 49004DP21 User manual Thermostat 8
11 Carrier APOLLO CONTROL 48/50HJ004-024 User manual Thermostat 11
12 Carrier 53DFS250-SL User manual Thermostat 15
13 Carrier APOLLO CONTROL 50HJQ004-016 User manual Thermostat 9
14 Carrier AQUAZONE 50QE900 User manual Thermostat 49
15 Carrier APOLLO CONTROL 50TFQ004-012 User manual Thermostat 5
16 Edelbrock 2116 User manual Thermostat 0
17 A&D MF-50 User manual Thermostat 8
18 A&D ML-50 User manual Thermostat 8
19 A&D MS-70 User manual Thermostat 15
20 Acu-Rite D1523 User manual Thermostat 2