Desa CGP10T user manual

User manual for the device Desa CGP10T

Device: Desa CGP10T
Category: Electric Heater
Manufacturer: Desa
Size: 0.27 MB
Added : 7/23/2014
Number of pages: 32
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa CGP10T. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa CGP10T.

For your convenience

If looking through the Desa CGP10T user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa CGP10T on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa CGP10T to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa CGP10T User manual - Online PDF
Advertisement
« Page 1 of 32 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa CGP10T but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa CGP10T. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

VENT-FREE PROPANE/LP GAS HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
®
Model: CGP10T and CGP10TL
WARNING: Improper installation,
WARNING: If the information in this manual is not fol-
adjustment, alteration, service, or
lowed exactly, a fire or explosion may result causing
maintenance can cause injury or
property damage, personal injury, or loss of life.
property damage. Refer to this
— Do not store or use gasoline or other flammable
manual for correct installation and
vapors and liquids in

Summary of the content on the page No. 2

SECTION PAGE CONTENTS Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ................................................................................... 4 Unpacking...................................................................................... 4 Product Features ............................................................................

Summary of the content on the page No. 3

SAFETY WARNINGS Continued INFORMATION WARNING: Any change to this heater or its controls can be dangerous. Continued 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/LP supply tank(s) outdoors. 3. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use an

Summary of the content on the page No. 4

Ignitor Button PRODUCT Control Knob IDENTIFICATION Grill Guard Glass Panel Heater Front Cabinet Panel Figure 1 - Vent-Free Propane/LP Gas Heater Install and use heater with care. Follow all local codes. In the absence of local LOCAL CODES codes, use the latest edition of The National Fuel Gas Code ANSI Z223.1, also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy,

Summary of the content on the page No. 5

AIR FOR WARNING WARNING ICON G 001 This heater shall not be installed in a confined space unless COMBUSTION provisions are provided for adequate combustion and ventilation AND air. Read the following instructions to insure proper fresh air for this and other fuel-burning appliances in your home. VENTILATION Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk

Summary of the content on the page No. 6

DETERMINING AIR FLOW FOR HEATER LOCATION AIR FOR Determining if You Have a Confined or Unconfined Space COMBUSTION Use this worksheet to determine if you have a confined or unconfined space. AND Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. VENTILATION 1. Determine the volume of the space (length x width x height). Continued Length x Width x Height = ___________________ cu. ft. (volume of spac

Summary of the content on the page No. 7

AIR FOR WARNING If the area in which the heater may be operated is smaller than COMBUSTION that defined as an unconfined space, provide adequate combus- AND tion and ventilation air by one of the methods described in the National Fuel Gas Code, ANSI Z223.1, 1992, Section 5.3. or appli- VENTILATION cable local codes. Continued VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you m

Summary of the content on the page No. 8

Ventilation Air From Outdoors AIR FOR Provide extra fresh air by using ventilation grills or ducts. You must provide two COMBUSTION permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These AND spaces include attics and crawl spaces. Follow the National Fuel Gas Code NFPA 54/ANSI Z223.1, Section 5.3, Air for Combustion and Ventilation for required size VENTILATION of ventilation grills or

Summary of the content on the page No. 9

INSTALLING TO NOTICE A qualified service person must install heater. Follow all local codes. WALL CHECK GAS TYPE Use only propane/LP gas. If your gas supply is not propane/LP, do not install heater. Call dealer where you bought heater for proper type heater. INSTALLATION ITEMS Before installing heater, make sure you have the items listed below. • external regulator (supplied by • ground joint union installer, see page 13) • test gauge connection * (see • piping (check local codes) Figure 13, pag

Summary of the content on the page No. 10

For convenience and efficiency, install heater INSTALLING TO • where there is easy access for operation, inspection, and service WALL • in coldest part of room CEILING Continued 36" Minimum 6" Minimum From Sides Of Heater Right Side Left Side 3" Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material FLOOR Figure 4 - Mounting Clearances As Viewed From Front of Heater THERMOSTAT SENSING BULB The thermostat sensing bulb is located inside the heater. Do not move this bulb during in

Summary of the content on the page No. 11

Installing Two Mounting Screws INSTALLING TO Note: Wall anchors and mounting screws are in hardware package. The hardware package is provided with heater. WALL Continued Attaching to wall stud method For attaching mounting screw to wall stud 1. Drill hole at marked location using 9/64" drill bit. 2. Insert mounting screw into wall stud. 3. Tighten screw until 1/16" space (thickness of penny) is between screwhead and wall. Attaching to wall anchor method Follow instructions below to attach mounti

Summary of the content on the page No. 12

Placing Heater On Mounting Screws INSTALLING TO 1. Locate two keyhole slots on back panel of heater (see Figure 9). 2. Place large openings of slots over screwheads. Slide heater down until screws WALL are in small portion of slots. Continued Keyhole Slots Figure 9 - Location Of Keyhole Slots On Back Panel Of Heater Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pu

Summary of the content on the page No. 13

CONNECTING NOTICE TO GAS A qualified service person must connect heater to gas supply. Follow all local codes. SUPPLY CAUTION Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If yo

Summary of the content on the page No. 14

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping CONNECTING and/or fittings. TO GAS SUPPLY Continued Pressure Regulator 3/8" NPT Pipe Nipple Heater Cabinet Ground Joint Union Tee Joint Manual Shutoff Valve * Reducer Test Bushing to Gauge From External 1/8" NPT Connection * Regulator (11" W.C. to 14" W.C. 1/8" NPT Plug Tap Pressure) Tee Joint 3" Minimum Sediment Trap Pipe Nipple Cap Figure 13 - Gas Connection * An A.G.A. design-certified manual shutoff valve with

Summary of the content on the page No. 15

3. Pressurize supply piping system by either using compressed air or CHECKING opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and GAS water to gas joints. Bubbles forming show a leak. CONNECTIONS 5. Correct all leaks at once. Continued Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Figure 14). 2. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank val

Summary of the content on the page No. 16

OFF HI OPERATING FOR YOUR SAFETY READ BEFORE LIGHTING HEATER WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT

Summary of the content on the page No. 17

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including OPERATING near the floor. If you smell gas, STOP! Follow “B” in the safety information HEATER at the top of page 16. If you don’t smell gas, go to the next step. Continued C-clockwise 5. Turn control knob counterclockwise to the PILOT position. Press in control knob for five (5) seconds (see Figure 16, page 16). Note: You may be running this heater for the first time after hooking up to gas supply. If so, the control k

Summary of the content on the page No. 18

OPERATING TO TURN OFF GAS TO APPLIANCE HEATER Shutting Off Heater Continued 1. Turn control knob clockwise to the OFF position. Clockwise 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise to the PILOT position. Clockwise THERMOSTAT CONTROL OPERATION The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The th

Summary of the content on the page No. 19

Check pilot flame pattern and burner flame pattern often. INSPECTING BURNER PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down. Pilot Burner Thermocouple GOOD PILOT/LP GRH/OV 007 Figure 18 - Correct Pilot Flame Pattern Pilot Burner Thermocouple BAD PILOT/LP GRH/OV 008 Figure 1

Summary of the content on the page No. 20

BURNER FLAME PATTERN INSPECTING Figure 20 shows a correct burner flame pattern. Figure 21 shows an incorrect BURNER burner flame pattern. The incorrect burner flame pattern shows yellow tipping of Continued the flame. It also shows the flame higher than 1/2 the glass panel height. WARNING If yellow tipping occurs, your heater could produce increased levels of carbon monoxide. If burner flame pattern shows yellow tipping, follow instructions at bottom of this page. NOTICE Do not mistake orange f


Alternative user manuals
# User manual Category Download
1 Desa 000 BTU SPC-30R User manual Electric Heater 0
2 Desa 000 Btu/hr Models User manual Electric Heater 0
3 Desa 000-12 User manual Electric Heater 0
4 Desa 100 User manual Electric Heater 0
5 Desa 104504-02 User manual Electric Heater 0
6 Desa 000-15 User manual Electric Heater 0
7 Desa 000-30 User manual Electric Heater 0
8 Desa 050 BTU User manual Electric Heater 0
9 Desa 105801-09 User manual Electric Heater 0
10 Desa 105838-02 User manual Electric Heater 0
11 Desa 10 User manual Electric Heater 0
12 Desa 101811-01C.pdf User manual Electric Heater 0
13 Desa 000-24 User manual Electric Heater 0
14 Desa 104506-02 User manual Electric Heater 0
15 Desa 106040-02 User manual Electric Heater 0
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13