Desa VTDMV18PA user manual

User manual for the device Desa VTDMV18PA

Device: Desa VTDMV18PA
Category: Electric Heater
Manufacturer: Desa
Size: 1.35 MB
Added : 4/17/2013
Number of pages: 20
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Desa VTDMV18PA. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Desa VTDMV18PA.

For your convenience

If looking through the Desa VTDMV18PA user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Desa VTDMV18PA on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Desa VTDMV18PA to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Desa VTDMV18PA User manual - Online PDF
Advertisement
« Page 1 of 20 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Desa VTDMV18PA but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Desa VTDMV18PA. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

VENTED DECORATIVE GAS LOG HEATER
OWNER’S OPERATION AND INSTALLATION MANUAL
VTDMV24NA, VTDMV24PA,
VTDMV18NA AND VTDMV18PA
WARNING: If the information in this manual is not fol-
lowed exactly, a fire or explosion may result causing
property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical swit

Summary of the content on the page No. 2

WARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer, service agency or the gas supplier. WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built fireplace, constructed of noncombustible material and connected to a working flue. (See pa

Summary of the content on the page No. 3

SAFETY INFORMATION WARNING: Do not use a blow- er insert, heat exchanger insert or WARNING: This product con- other accessory not approved for tains and/or generates chemicals use with this appliance. known to the State of California to cause cancer or birth defects WARNING: This appliance or other reproductive harm. is equipped for (natural or pro- pane/LP) gas. Field conversion WARNING: Keep flue open is not permitted. when operating unit. WARNING: Do not allow fans IMPORTANT: Rea

Summary of the content on the page No. 4

9. Do not use a blower insert, heat exchanger SAFETY INFORMATION insert or other accessory not approved for use Continued with this log set. 10. The installation and provisions for combustion Keep the appliance area clear and ventilation air must conform with the Na- and free from combustible ma- tional Fuel Gas Codes, ANSI Z233.1/NFPA 54, terials, gasoline and other flam- Section 5.3, Air for combustion and Ventilation. mable vapors and liquids. 11. Do not run heater • where flammable liquid

Summary of the content on the page No. 5

PRODUCT INSTALLATION IDENTIFICATION WARNING: A qualified ser- vice person must install heater. WARNING: Failure to posi- Follow all local codes. tion the parts in accordance with these diagrams or failure WARNING: Before installing to use only parts specifically in a solid fuel burning fireplace, approved with this appliance the chimney flue and firebox may result in property damage must be cleaned of soot, creo- or personal injury. sote, ashes and loose paint by a qualified chimney clean

Summary of the content on the page No. 6

drawing it up the chimney. If the smoke spills out INSTALLATION into the room, extinguish the flame and remove any Continued obstruction until proper venting is achieved. CHECK GAS TYPE The chimney flue damper must be fixed open to pro- Use the correct gas type (natural or propane/LP) for vide a minimum of 32 square inch of free air opening your unit. If your gas supply is not correct, do not at all times during operation of the log set. A damper instal in fireplace. Call dealer where you bou

Summary of the content on the page No. 7

INSTALLATION CAUTION: Never connect Continued propane/LP unit directly to the INSTALLING APPLIANCE propane/LP supply. This unit re- quires an external regulator (not WARNING: Special care is supplied). Install the external required if you are installing the regulator between the unit and unit into a sunken fireplace. You the propane/LP supply. must raise the fireplace floor to allow access to gas log controls. This will insure adequate air WARNING: Never connect flow and guard against

Summary of the content on the page No. 8

Locate sediment trap where trapped matter is not INSTALLATION likely to freeze. A sediment trap traps moisture and Continued contaminants. This keeps them from going into heater controls. If sediment trap is not installed or CAUTION: Use only new, black is installed wrong, heater may not run properly. iron or steel pipe. Internally-tinned copper tubing may be used in CAUTION: Avoid damage to certain areas. Check your local gas control. Hold gas control codes. Use pipe of 1/2" diamet

Summary of the content on the page No. 9

Pressure Testing Appliance Gas INSTALLATION Connections Continued 1. Open equipment shutoff valve (see Figure 8). 6. Reconnect heater and equipment shutoff 2. Open main gas valve located on or near gas valve to gas supply. Check reconnected fit- meter for natural gas or open propane/LP tings for leaks. supply tank valve. Test Pressures Equal To or Less Than 3. Make sure control knob of appliance is in the 1/2 PSIG (3.5 kPa) OFF position. 1. Close equipment shutoff valve (see Figure 8). eck

Summary of the content on the page No. 10

5. Wait five (5) minutes to clear out any gas. OPERATING APPLIANCE If you then smell gas, STOP! Follow "B" in FOR YOUR SAFETY the safety information in column 1. If you READ BEFORE LIGHTING don't smell gas, go on the next step. 6. Press in and turn control knob counter- clockwise to the PILOT position. WARNING: Keep flue open Press in control knob for five (5) seconds when operating unit. (see Figure 12). 7. With control knob pressed in, press and release WARNING: If you do not fol- ign

Summary of the content on the page No. 11

OPERATING APPLIANCE INSPECTING BURNERS Continued Check pilot flame pattern and burner flame pat- terns often. NOTICE: You must light the pilot PILOT FLAME PATTERN before using the hand-held re- You can view the pilot light through the pilot mote control unit. See Lighting viewing hole on the pilot bracket. This is located Instructions on page 10. under the front grate bar on the right side of the log set. After lighting, let pilot flame burn for about Figure 15 shows a correct pilot flame patt

Summary of the content on the page No. 12

• Keep area around log set clean and clear of INSPECTING BURNERS debris. Continued • Periodically inspect the air mixer and burner If burner flame pattern is incorrect, as shown in tube for foreign matter blocking the air inlet Figure 18. and flame holes. • turn appliance off (see To Turn Off Gas to Ap- • Once every year a qualified agency or certified pliance, page 10) chimney sweep should examine and clean the • see Troubleshooting, page 13 venting system of the fireplace. Dark Orange SERVIC

Summary of the content on the page No. 13

TROUBLESHOOTING WARNING: Turn off appliance and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY When ignitor button is pressed, 1. Ignitor electrode not con- 1. Reconnect ignitor cable there is no spark at ODS/pilot nected to ignitor cable 2.

Summary of the content on the page No. 14

TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY ODS/pilot lights but flame goes 1. Control knob not fully 1. Press in control knob fully out when control knob is re- pressed in leased 2. Control knob not pressed in 2. After ODS/pilot lights, keep long enough control knob pressed in for 30 seconds 3. Safety interlock system has 3. Wait one minute for safety in- been triggered terlock system to reset. Repeat ignition operation 4. Equipment shutoff valve not 4. Fully open equipme

Summary of the content on the page No. 15

TROUBLESHOOTING Continued OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Dark orange flame in burner dur- 1. Not enough air 1. Check burner(s) for dirt ing burner combustion and debris. If found, clean burner(s) (see Cleaning and Maintenance, page 12) 2. Gas regulator defective 2. Replace gas regulator Slight smoke or odor during initial 1. Residues from manufacturing 1. Problem will stop after a few operation processes and log curing hours of operation Produces a whistling noise when 1. Turning cont

Summary of the content on the page No. 16

TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating appliance where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, c

Summary of the content on the page No. 17

SPECIFICATIONS This appliance has been design certified to ANSI ZZ1.60-2003 and CSA 2.26-2003 Decorative Gas Appliances for Installation in Solid Fuel Burning Fireplaces by OMNI Test Laboratories. VTDMV18NA VTDMV18PA VTDMV24NA VTDMV24PA Btu (Variable) 36,000/53,000 35,000/45,000 36,000/53,000 35,000/45,000 Type Gas Natural Gas Only Propane/LP Only Natural Gas Only Propane/LP Only Ignition Piezo Piezo Piezo Piezo Manifold Pressure 3.5" W.C. 10" W.C. 3.5" W.C. 10" W.C. Inlet Gas Pressure (

Summary of the content on the page No. 18

ILLUSTRATED PARTS BREAKDOWN VTDMV24NA, VTDMV24PA VTDMV18NA, VTDMV18PA 17 16 15 7 1 9 8 6 13 5 10 3 14 12 2 4 1 1 18 www.desatech.com 114926-01B

Summary of the content on the page No. 19

PARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 12 of this manual. KEY PART NUMBER NO. VTDMV24NA VTDMV24PA VTDMV18NA VTDMV18PA DESCRIPTION QTY. 1 111793-01 111793-01 111808-02 111808-02 Grate 1 2 111817-02 111817-02 111817-02 111817-02 Flexible Tube 1 3 099998-01 099998-01 099998-01 099998-01 Fan Switch 1 4 103784-02 103784-02 103784-02 103784-02 Knob Extension (HI/LOW) 1 5 103784-01 103784-

Summary of the content on the page No. 20

WARRANTY INFORMATION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. LIMITED WARRANTY VENTED GAS LOG APPLIANCES DESA warrants this product to be free from defects in materials and components for four (4) years from the date of


Alternative user manuals
# User manual Category Download
1 Desa 000 BTU SPC-30R User manual Electric Heater 0
2 Desa 000 Btu/hr Models User manual Electric Heater 0
3 Desa 000-12 User manual Electric Heater 0
4 Desa 100 User manual Electric Heater 0
5 Desa 104504-02 User manual Electric Heater 0
6 Desa 000-15 User manual Electric Heater 0
7 Desa 000-30 User manual Electric Heater 0
8 Desa 050 BTU User manual Electric Heater 0
9 Desa 105801-09 User manual Electric Heater 0
10 Desa 105838-02 User manual Electric Heater 0
11 Desa 10 User manual Electric Heater 0
12 Desa 101811-01C.pdf User manual Electric Heater 0
13 Desa 000-24 User manual Electric Heater 0
14 Desa 104506-02 User manual Electric Heater 0
15 Desa 106040-02 User manual Electric Heater 0
16 A.O. Smith AH - 290 User manual Electric Heater 6
17 A.O. Smith AHD 290 User manual Electric Heater 7
18 A.O. Smith AHDS 290 User manual Electric Heater 0
19 A.O. Smith ST 3000 User manual Electric Heater 5
20 A.O. Smith WATER HEATERS User manual Electric Heater 13