Goodman Mfg SSZ 14 SEER user manual

User manual for the device Goodman Mfg SSZ 14 SEER

Device: Goodman Mfg SSZ 14 SEER
Category: Heat Pump
Manufacturer: Goodman Mfg
Size: 0.45 MB
Added : 7/6/2014
Number of pages: 28
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Goodman Mfg SSZ 14 SEER. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Goodman Mfg SSZ 14 SEER.

For your convenience

If looking through the Goodman Mfg SSZ 14 SEER user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Goodman Mfg SSZ 14 SEER on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Goodman Mfg SSZ 14 SEER to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Goodman Mfg SSZ 14 SEER User manual - Online PDF
Advertisement
« Page 1 of 28 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Goodman Mfg SSZ 14 SEER but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Goodman Mfg SSZ 14 SEER. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
TECHNICAL MANU TECHNICAL MANUAL AL
TECHNICAL MANU TECHNICAL MANU TECHNICAL MANUAL AL AL
SSZ 14 SEER
Split System Heat Pumps
• Refer to Service Manual RS6200005 for installation, operation, and troubleshooting information.
• All safety information must be followed as provided in the Service Manual.
• Refer to the appropriate Parts Catalog for part number information.
• Models listed on page 3.
RT6213005 Rev. 3
This manual is to be used by qualified, professionally trained HVAC technicians only.

Summary of the content on the page No. 2

PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. S S Z 14 036 1 A A Minor Revision Brand Name A: Initial Release G: Goodman (Standard Feature Set Models) S: Goodman (High Feature Set Models) Major Revision A: Initial Release Product Family S: Split System Electrical 1: 208/230V/60Hz/1ph Product Type 3: 208/230V/60Hz/3ph 4: 460V/60Hz/3ph C: Condenser R-22 X:

Summary of the content on the page No. 3

PRODUCT IDENTIFICATION The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. SSZ140181A* SSZ140241A* SSZ140301A* SSZ140361A* SSZ140421A* SSZ140481A* SSZ140601A* * Indicates minor revision & is not used for order entry or inventory management The United States Environmental Protection Agency (“EPA”) has issued various regulations re- W WA ARNI RNING NG garding the introduction and dispos

Summary of the content on the page No. 4

PRODUCT DESIGN These clearances will help avoid air recirculation. If installing SSZ14 models are available in 1 1/2 through 5 ton sizes and two or more units at the same location, allow at least 24 use R-410A refrigerant. They are designed for 208/230 volt inches between units. If only one side is restricted (for ex- single phase applications. ample, against the outside wall of a house), the unit may be The condenser air is pulled through the condenser coil by a placed as close as 8" to that on

Summary of the content on the page No. 5

HEAT PUMP SPECIFICATIONS SSZ140[18,30, 342,48,60]1AA-AE; SSZ140241AA-AH; SSZ140361AA-AG Cooling Capacity, BTUH 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Compressor R.L. Amps 8.97 12.82 14.10 16.67 17.95 19.87 26.41 L.R. Amps 48.0 58.3 73.0 79.0 112.0 109.0 130.0 Low Pressure Switch Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG High Pressure Switch Open 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSI

Summary of the content on the page No. 6

HEAT PUMP SPECIFICATIONS SSZ140[18,30,42,48,60]1AF; SSZ140241AJ; SSZ140361AH Cooling Capacity, BTUH 18,000 24,000 30,000 36,000 42,000 48,000 60,000 Compressor R.L. Amps 9.0 12.82 14.10 16.67 17.95 19.9 26.41 L.R. Amps 48.0 58.3 73.0 79.0 112.0 109.0 130.0 Low Pressure Switch Open 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG 22 PSIG Close 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG 50 PSIG High Pressure Switch Open 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG 610 PSIG Close 420 P

Summary of the content on the page No. 7

COOLING PERFORMANCE DATA SSZ140181A* 7 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 596367715963677159636771 59 63 67 7159 6367 7159 6367 71 MBh 17.6 18.3 20.0 - 17.2 17.9 19.6 - 16.8 17.4 19.1 - 16.4 17.0 18.6 - 15.6 16.2 17.7 - 14.4 15.0 16.4 - S/T 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0

Summary of the content on the page No. 8

COOLING PERFORMANCE DATA SSZ140181A* 8 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 596367715963677159636771 59 63 67 7159 6367 7159 6367 71 MBh 18.3 18.7 19.9 21.3 17.8 18.2 19.5 20.8 17.4 17.8 19.0 20.3 17.0 17.4 18.5 19.8 16.1 16.5 17.6 18.8 14.9 15.3 16.3 17.4 S/T 0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.54 1.00 0.92 0.75 0.56 1.00 0.94 0.77 0.5

Summary of the content on the page No. 9

COOLING PERFORMANCE DATA SSZ140241A* 9 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59636771596367715963677159 63 67 71 59 63 67 71 59636771 MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5 - 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 - S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.87 0.72 0.

Summary of the content on the page No. 10

COOLING PERFORMANCE DATA SSZ140241A* 10 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59636771596367715963677159 63 67 71596367715963 6771 MBh 24.3 24.9 26.6 28.4 23.8 24.3 26.0 27.7 23.2 23.7 25.3 27.1 22.6 23.1 24.7 26.4 21.5 22.0 23.5 25.1 19.9 20.4 21.8 23.3 S/T 0.94 0.88 0.72 0.54 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.57 1.00 0.97 0.79 0.59 1.

Summary of the content on the page No. 11

COOLING PERFORMANCE DATA SSZ140301A* 11 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 5963 677159 6367 71 59 63 67 7159 63 67 71 59 6367 715963 6771 MBh 28.2 29.3 32.0 - 27.6 28.6 31.3 - 26.9 27.9 30.6 - 26.3 27.2 29.8 - 24.9 25.8 28.3 - 23.1 23.9 26.2 - S/T 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.84 0.70 0.48 - 0.86 0.72 0.50 - 0.90 0.75 0.52 - 0.90

Summary of the content on the page No. 12

COOLING PERFORMANCE DATA SSZ140301A* 12 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140301A* / CA*F3642*6A*+TXV / MBR1600**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59 636771 5963 6771 59 63 67 7159 63 67 715963 6771 5963 6771 MBh 29.2 29.8 31.9 34.1 28.5 29.2 31.1 33.3 27.9 28.5 30.4 32.5 27.2 27.8 29.7 31.7 25.8 26.4 28.2 30.1 23.9 24.4 26.1 27.9 S/T 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.58 1.00 1.00 0.80 0.59 1.00 1.00 0.

Summary of the content on the page No. 13

COOLING PERFORMANCE DATA SSZ140361A* 13 EXPANDED PERFORMANCE DATA MODEL: SSZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1 Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 33.9 35.1 38.5 - 33.1 34.3 37.6 - 32.3 33.5 36.7 - 31.5 32.7 35.8 - 30.0 31.1 34.0 - 27.8 28.8 31.5 - S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48

Summary of the content on the page No. 14

COOLING PERFORMANCE DATA SSZ140361A* 14 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140361A* / CA*F4860*6A*+TXV / MBR1600**-1 Outdoor Ambient Temperature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59 63 6771 59 6367 71 59 63 677159 63 67 715963677159636771 MBh 35.09 35.86 38.31 40.95 34.28 35.03 37.42 40.00 33.46 34.19 36.53 39.05 32.64 33.36 35.64 38.10 31.01 31.69 33.86 36.19 28.73 29.35 31.36 33.53 S/T 0.90 0.85 0.69 0.51 0.93 0.88 0.71 0.53 0.96 0.90 0.

Summary of the content on the page No. 15

COOLING PERFORMANCE DATA SSZ140421A* 15 EXPANDED PERFORMANCE DATA MODEL: SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 39.2 40.6 44.5 - 38.3 39.7 43.5 - 37.4 38.7 42.4 - 36.5 37.8 41.4 - 34.6 35.9 39.3 - 32.1 33.3 36.4 - S/T 0.77 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.85 0.71 0.49 - 0.88 0.74 0.51 - 0.89 0.74 0.5

Summary of the content on the page No. 16

COOLING PERFORMANCE DATA SSZ140421A* 16 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140421A* / CA*F4860*6A*+TXV / MBR2000**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 5963 67715963677159 63 677159 63 67 71596367715963 6771 MBh 40.6 41.5 44.3 47.3 39.6 40.5 43.3 46.2 38.7 39.5 42.2 45.1 37.7 38.6 41.2 44.0 35.9 36.6 39.1 41.8 33.2 33.9 36.3 38.8 S/T 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.96 0.78 0.59 1.00 1.00 0.81 0.6

Summary of the content on the page No. 17

COOLING PERFORMANCE DATA SSZ140481A* 17 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 5963 67 71 59 63677159 63 677159 63 67 71 59 63 67 7159636771 MBh 45.1 46.7 51.2 - 44.0 45.6 50.0 - 43.0 44.5 48.8 - 41.9 43.5 47.6 - 39.8 41.3 45.2 - 36.9 38.2 41.9 - S/T 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.48 - 0.87 0.73 0.50 - 0.88

Summary of the content on the page No. 18

COOLING PERFORMANCE DATA SSZ140481A* 18 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140481A* / CA*F4860*6A*+TXV / MBR2000**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 5963 67 71 59 63677159 63 677159 63 67 71 59 63 67 7159636771 MBh 46.7 47.7 50.9 54.4 45.6 46.6 49.7 53.2 44.5 45.5 48.6 51.9 43.4 44.3 47.4 50.6 41.2 42.1 45.0 48.1 38.2 39.0 41.7 44.6 S/T 0.95 0.89 0.73 0.54 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.

Summary of the content on the page No. 19

COOLING PERFORMANCE DATA SSZ140601A* 19 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 MBh 55.4 57.4 62.9 - 54.1 56.1 61.4 - 52.8 54.7 59.9 - 51.5 53.4 58.5 - 48.9 50.7 55.6 - 45.3 47.0 51.5 - S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.85 0.71 0.

Summary of the content on the page No. 20

COOLING PERFORMANCE DATA SSZ140601A* 20 EXPANDED PERFORMANCE DATA COOLING OPERATION MODEL: SSZ140601A* / CA*F4860*6A*+TXV / MBE2000**-1 Outdoor Am bient Tem perature 65 75 85 95 105 115 Entering Indoor Wet Bulb Tem perature IDB*Airflow 59636771596367715963677159 63 67 7159 6367 7159 6367 71 MBh 57.3 58.6 62.6 66.9 56.0 57.2 61.1 65.3 54.6 55.8 59.6 63.8 53.3 54.5 58.2 62.2 50.6 51.7 55.3 59.1 46.9 47.9 51.2 54.7 S/T 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.78 0.5


Alternative user manuals
# User manual Category Download
1 Goodman Mfg . Co. LP.ENERGY-EFFICIENT User manual Heat Pump 3
2 Goodman Mfg . Co. LP.gsz11 remote s User manual Heat Pump 0
3 Goodman Mfg . Co. LP.GSZ110904AB User manual Heat Pump 0
4 Goodman Mfg . Co. LP.GSZ110903AB User manual Heat Pump 1
5 Goodman Mfg . Co. LP.GSZ110904AA User manual Heat Pump 0
6 Goodman Mfg . Co. LP.GSZ110903AA User manual Heat Pump 0
7 Goodman Mfg . Co. LP.GSZ111203AB User manual Heat Pump 7
8 Goodman Mfg . Co. LP.GSZ111204AA User manual Heat Pump 0
9 Goodman Mfg . Co. LP.GSH13 Remote User manual Heat Pump 8
10 Goodman Mfg . Co. LP.GSZ111203AA User manual Heat Pump 1
11 Goodman Mfg . Co. LP.GSZ111204AB User manual Heat Pump 0
12 Goodman Mfg . Co. LP.RP-430C User manual Heat Pump 5
13 Goodman Mfg . Co. LP.GSZ13 User manual Heat Pump 19
14 Goodman Mfg . Co. LP.SS-ICPKF User manual Heat Pump 1
15 Goodman Mfg GPH1324M41AB User manual Heat Pump 0
16 Edelbrock 15005 User manual Heat Pump 0
17 A.O. Smith AH User manual Heat Pump 2
18 ACS 882.00217.00 User manual Heat Pump 1
19 A.O. Smith AHD 290 User manual Heat Pump 3
20 AC International SELF-PRIMING CENTRIFUGAL PUMPS User manual Heat Pump 5