A.O. Smith 300A user manual

User manual for the device A.O. Smith 300A

Device: A.O. Smith 300A
Category: Water Heater
Manufacturer: A.O. Smith
Size: 1.52 MB
Added : 6/18/2013
Number of pages: 40
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for A.O. Smith 300A. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with A.O. Smith 300A.

For your convenience

If looking through the A.O. Smith 300A user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual A.O. Smith 300A on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual A.O. Smith 300A to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
A.O. Smith 300A User manual - Online PDF
Advertisement
« Page 1 of 40 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual A.O. Smith 300A but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to A.O. Smith 300A. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

®
CYCLONE Xi Model BTH 300A, 400A, 500A
COMMERCIAL GAS WATER HEATER
GAS-FIRED POWER BURNER
FOR DOMESTIC HOT WATER
• INSTALLATION • OPERATION • SERVICE • MAINTENANCE • LIMITED WARRANTY
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing property
damage, personal injury or death.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO

Summary of the content on the page No. 2

ROUGH-IN-DIMENSIONS GAS VALVE PIPING BTH-300 1 1/4" NPT BTH-400 1 1/4" NPT BTH-500 1 1/2" NPT TABLE 1 RECOVERY CAPACITIES. U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED TYPE OF INPUT Approx. F° 20F° 30F° 40F° 50F° 60F° 70F° 80F° 90F° 100F° 110° 120F° 130F° 140F° MODEL GAS BTUH KW Capacity C° 11C° 17C° 22C° 28C° 33C° 39C° 44C° 50C° 56C° 61C° 67C° 72C° 78C° 300,000 130 US Gals. GPH 1746 1164 873 699 582 499 436 388 349 318 291 269 250 BTH-300 NAT

Summary of the content on the page No. 3

TABLE OF CONTENTS ROUGH-IN DIMENSIONS ......................................................................... Water (Potable) Heating & Space Heating ..........................................7 FOREWORD ............................................................................................. Heater Wiring .................................................................................7-9 FEATURES ........................................................................................

Summary of the content on the page No. 4

“AT A GLANCE” BTH 300/400/500 QUICK INSTALLATION TIPS Horizontal Sidewall Venting Vertical Rooftop Venting 4

Summary of the content on the page No. 5

The temperature may be adjusted from 80°F/27°C to 180°F/82°C. Valves for reducing point-of-use temperature by mixing cold The temperature was adjusted to 120°F/49°C before the heater and hot water are available (see Figure 2). Also available are was shipped from the factory. It is recommended that lower water inexpensive devices that attach to faucets to limit hot water temperatures be used to avoid the risk of scalding. It is further temperatures. Contact a licensed plumber or the local plum

Summary of the content on the page No. 6

THE HEATER SHALL BE LOCATED OR PROTECTED SO IT IS NOT CIRCULATING PUMP SUBJECT TO PHYSICAL DAMAGE BY A MOVING VEHICLE. A circulating pump is used when a system requires a circulating loop or there is a storage tank used in conjunction with the heater. Refer to the DO NOT LOCATE THE HEATER WHERE NOISE FROM THE piping diagrams at rear of manual for electrical hookup information and EXHAUST OR INTAKE WILL BE OBJECTIONABLE. THIS install in accordance with the current edition of the National El

Summary of the content on the page No. 7

MECHANICAL EXHAUSTING OF ROOM AIR CLEARANCES Where an exhaust fan is installed in the same room with a heater, These heaters are approved for installation on combustible flooring sufficient openings for air must be provided in the walls. UNDERSIZED in an alcove when the minimum clearances from any combustion OPENINGS WILL CAUSE AIR TO BE DRAWN INTO THE ROOM construction are followed as indicated in Figure 4. THROUGH THE HEATER’S VENTING SYSTEM, CAUSING POOR COMBUSTION. SOOTING MAY RESULT

Summary of the content on the page No. 8

EXEMPTIONS INSTALLATION REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters installed in every 1. The equipment listed in Chapter 10 entitled “Equipment Not dwelling, building or structure used in whole or in part for residential Required To Be Vented” in the most current edition of NFPA 54 purposes,

Summary of the content on the page No. 9

US DIRECT VENT CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO THE AIR INTAKE IN WINDY/COLD AREAS, THE MAXIMUM PRACTICAL DISTANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED. CANADIAN DIRECT VENT FIGURE 5. 9

Summary of the content on the page No. 10

US HORIZONTAL VENT CAUTION TO PREVENT EXHAUSTING PRODUCTS FROM CIRCULATING TO THE AIR INTAKE IN WINDY/COLD AREAS, THE MAXIMUM PRACTICAL DISTANCE BETWEEN THESE TWO TERMINALS IS RECOMMENDED. CANADIAN HORIZONTAL VENT FIGURE 6. 0 

Summary of the content on the page No. 11

WARNING WARNING NEVER OPERATE THE HEATER UNLESS IT IS VENTED TO THE WHEN THE UNIT IS TO BE SETUP AS A DIRECT VENT, OUTDOORS AND HAS ADEQUATE AIR SUPPLY TO AVOID RISKS OF THE INTAKE GUARD AND THE BALANCE PLATE MUST BE IMPROPER OPERATION, FIRE, EXPLOSION OR ASPHYXIATION. REMOVED. THE INLET VENT PIPE MAY THEN BE GLUED TO THE AIR INTAKE (see Figure 8) PROVIDED ON THE UNIT. VENT PIPE TERMINATION NOTE: Before installing venting, determine place of vent pipe termination. See Figure 5 and 6 bef

Summary of the content on the page No. 12

Slide the pipe through the wall and insert into coupling on the 2. The horizontal centerline of the intake vent terminal may not be other side of the wall, making sure that the vent terminal ends located lower than the horizontal centerline of the exhaust vent up pointed in the correct position. See Figure 10. terminal (see Figure 9). EXHAUST VENT TERMINAL FIGURE 9. INSTALLATION SEQUENCE For installations in the City of Los Angeles, California Category IV PVC Pipe such as that manufactured

Summary of the content on the page No. 13

2. Drill a pilot hole approximately 1/4" (6 mm) outside of the marked 3. The unit is certified to a minimum amount of 4-inch pipe for circle. This pilot hole is used as a starting point for a saws- the exhaust venting arrangement of 15-equivalent feet. This is all or sabre saw blade. Cut around the marked circle staying the minimum amount of pipe required for the exhaust venting approximately one quarter inch outside the line. (This will allow arrangement. The intake venting arrangement is

Summary of the content on the page No. 14

contacts are normally open. When the fan increases the pressure VENT PIPE PREPARATION in the burner, the pressure switch will allow the electrical contacts to close. The pressure switch is connected to the burner tap by a . INITIAL PREPARATION piece of tygon tubing. This tubing must be connected in order for the switch to change the electrical contacts. The controller requires A. Make sure the solvent cement you are planning to use is that the electrical contacts on this air flow switc

Summary of the content on the page No. 15

CAUTION WARNING THE WATER HEATER IS POLARITY SENSITIVE. BEFORE THE HEATER IS NOT INTENDED FOR OPERATION AT HIGHER APPLYING ELECTRICITY TO THIS HEATER BE CERTAIN THAT THAN 11.0" WATER COLUMN (2.74 Kpa) FOR NATURAL GAS AND SUPPLY NEUTRAL WIRE TO GROUND CHECK INDICATES ZERO 14.0" W.C. (3.49kPa) FOR PROPANE GAS SUPPLY PRESSURE. VOLTAGE. HIGHER GAS SUPPLY PRESSURES REQUIRE SUPPLEMENTAL REDUCING SERVICE REGULATION. EXPOSURE TO HIGHER GAS SUPPLY PRESSURE MAY CAUSE DAMAGE TO THE GAS HOT SUR

Summary of the content on the page No. 16

To prevent damage, care must be taken not to apply too much torque RELIEF VALVE when attaching gas supply pipe to gas valve inlet. This heater is equipped with an approved temperature and pressure Apply joint compounds (pipe dope) sparingly and only to the relief valve. ASME ratings cover pressure relief. CSA ratings cover male threads of pipe joints. Do not apply compound to the first release rate with temperature actuation. two threads. Use compounds resistant to the action of liquefied

Summary of the content on the page No. 17

codes or contact the water supplier or local plumbing inspector on CLEAN ELECTRICITY FOR PROPER OPERATION. INSTALLING how to control this situation. THE HEATER ON A BRANCH CIRCUIT THAT HAS ELECTRONIC NOISE, IS SUBJECT TO FLUCTUATIONS IN VOLTAGE LEVEL OR HAS AN APPLIANCE WHICH GENERATES EMF OF WATER (POTABLE) HEATING AND SPACE HEATING RFI INTERFERENCE CAN CAUSE THE CONTROLLER TO MALFUNCTION. A HIGH QUALITY POWER CONDITIONER 1. All piping components connected to this unit for space heating

Summary of the content on the page No. 18

BTH 300 WIRING DIAGRAM FIGURE 15. 8

Summary of the content on the page No. 19

BTH 400 AND 500 WIRING DIAGRAM FIGURE 16. 9

Summary of the content on the page No. 20

inside the tank. The second temperature on this screen is the OPERATION Operating Set Point. The Operating Set Point is the temperature at which the water heater will maintain the water inside the tank. SEQUENCE OF OPERATION The third line on the screen is a text description of the Operational State of the water heater (please see Operating States for more Typical Control/Appliance Operating Sequence details). 1. When the control is powered, it should display the unit model, water temperat


Alternative user manuals
# User manual Category Download
1 A.O. Smith 000 User manual Water Heater 8
2 A.O. Smith 101 User manual Water Heater 3
3 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
4 A.O. Smith 104 Series User manual Water Heater 3
5 A.O. Smith 104 - 110 User manual Water Heater 6
6 A.O. Smith 105 Series User manual Water Heater 1
7 A.O. Smith 15 User manual Water Heater 0
8 A.O. Smith 2100 User manual Water Heater 0
9 A.O. Smith 1850 User manual Water Heater 0
10 A.O. Smith 185874-001 User manual Water Heater 0
11 A.O. Smith 185762-000 User manual Water Heater 0
12 A.O. Smith 2500 User manual Water Heater 1
13 A.O. Smith 184769-000 User manual Water Heater 1
14 A.O. Smith 1300 User manual Water Heater 0
15 A.O. Smith 197835-001 User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6