A.O. Smith Vertex 100 Power Vent DV Series 120 user manual

User manual for the device A.O. Smith Vertex 100 Power Vent DV Series 120

Device: A.O. Smith Vertex 100 Power Vent DV Series 120
Category: Water Heater
Manufacturer: A.O. Smith
Size: 7.54 MB
Added : 11/5/2014
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for A.O. Smith Vertex 100 Power Vent DV Series 120. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with A.O. Smith Vertex 100 Power Vent DV Series 120.

For your convenience

If looking through the A.O. Smith Vertex 100 Power Vent DV Series 120 user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual A.O. Smith Vertex 100 Power Vent DV Series 120 on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual A.O. Smith Vertex 100 Power Vent DV Series 120 to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
A.O. Smith Vertex 100 Power Vent DV Series 120 User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual A.O. Smith Vertex 100 Power Vent DV Series 120 but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to A.O. Smith Vertex 100 Power Vent DV Series 120. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Instruction Manual
resIdentIal Gas water heaters
power vent/power dIrect vent Gas Models
wIth hot surface IGnItIon
Ashland City, TN 37015
www.hotwater.com
• for Your safety •
AN ODORANT IS ADDED TO THE GAS USED
Thank you for buying this energy efficient water heater.
BY THIS WATER HEATER.
We appreciate your confidence in our products.
all technIcal and warrantY questIons: SHOULD BE DIRECTED TO THE LOCAL DEALER FROM WHOM THE WATER HEATER WAS
PURCHASED. IF YOU ARE UNSUCCESSFUL, CALL THE TECHN

Summary of the content on the page No. 2

table of contents TABLE OF CONTENTS ........................................................................2 Applicators ..............................................................................31 Controls and Switches ..................................................................33 SAFE INSTALLATION, USE AND SERvICE ........................................3 APPROvALS ........................................................................................3 Blower Prover Switch .....

Summary of the content on the page No. 3

safe InstallatIon, use and servIce The proper installation, use and servicing of this water heater is extremely important to your safety and the safety of others. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. It is very important that the meaning of each safety message is understood by you and others who

Summary of the content on the page No. 4

General safetY InforMatIon precautIons hYdroGen Gas flaMMable DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. Immediately call a qualified service agency to inspect the appliance and to make a determination on what steps should be taken next. Explosion Hazard If the unit is exposed to the following, do not operate heater until all corrective steps have been made by a qualified service agency. Flammable hydrogen gases may be present. 1. External fire. Keep all ignition sources awa

Summary of the content on the page No. 5

General safetY InforMatIon 5

Summary of the content on the page No. 6

General safetY InforMatIon Fire or Explosion Hazard Fire Hazard Do not store or use gasoline or other flammable vapors and For continued protection against liquids in the vicinity of this or any other appliance. risk of fire: Avoid all ignition sources if you smell gas. Do not install water heater on Do not expose water heater controls to excessive gas carpeted floor. pressure. Do not operate water heater if Use only the gas shown on the water heater rating plate. flood damaged. Maintain require

Summary of the content on the page No. 7

IntroductIon Thank You for purchasing this water heater. Properly installed and Detailed installation diagrams are also found in this manual. maintained, it should give you years of trouble free service. These diagrams will serve to provide the installer with a reference. It is essential that all venting, water piping, gas piping and wiring be installed as shown. abbrevIatIons used Particular attention should be given to the installation of Abbreviations found in this Instruction Manual incl

Summary of the content on the page No. 8

features and coMponents Get to Know Your water heater - Gas Models a control assembly M display enclosure Z t/p relief v alve b blocked Inlet switch ** n exhaust elbow assembly aa rating plate c blocked outlet switch ** o condensate t ubing bb labels d fan prover switch p off/on switch cc drain v alve e blower assembly q display label ** dd v ent t erminal f burner assembly r hot w ater outlet ee drain pan G flame sensor t Gas supply ff anode h hot surface Ign

Summary of the content on the page No. 9

InstallatIon consIderatIon rouGh In dIMensIons fIGure 1a. rough-In-dimensions Units A B C D E F Inches 66.75 49.25 22.00 15.75 3.00 8.00 cm 169.5 125.09 55.88 40.00 7.62 20.32 t op/side Inlet and outlet: 3/4” npt Gas Inlet: 1/2” npt capacity, Gas and electrical characteristics Approximate Capacity Manifold Pressure Electrical Characteristics U.S. Gals. Liters Gas Type “WC kPA Volts/Hz Amperes 50 189 Nat./LP 0” 0” 120/60 <5 Maximum supply pressure: 14 inches w .c. (3.48kpa) Minimum supply pressur

Summary of the content on the page No. 10

locatInG the w ater heater Carefully choose a location for the new water heater. The placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. CAUTION Property Damage Hazard All water heaters eventually leak. • • Do not install without adequate drainage. Whether replacing an existing water heater or installing the water heater in a new location observe the following critical points: 1. The water heater must b

Summary of the content on the page No. 11

in an alcove or closet, the entire floor must be covered by the panel. • Do not apply insulation to the top of the water heater, as this will Failure to heed this warning may result in a fire hazard. interfere with safe operation of the blower assembly. • Do not cover the outer door, thermostat or temperature & pressure relief valve. • Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference. • Do obtain new warning and instruction labels

Summary of the content on the page No. 12

ventilation systems, clothes dryers and fireplaces shall also be outdoor aIr throuGh two openInGs considered in determining the adequacy of a space to provide combustion, ventilation and dilution air. unusuall Y tIGht constructIon In unconfined spaces in buildings, infiltration may be adequate to provide air for combustion, ventilation and dilution of flue gases. However, in buildings of unusually tight construction (for example, weather stripping, heavily insulated, caulked, vapor barrier,

Summary of the content on the page No. 13

2 1. 1 square inch per 3000 Btu/hr (700 mm per kW) of the total aIr froM other Indoor spaces input rating of all appliances located in the enclosure, and 2. Not less than the sum of the areas of all vent connectors in the space. outdoor aIr throuGh two horIZontal ducts fIGure 7. fIGure 6. The confined space shall be provided with two permanent The confined space shall be provided with two permanent horizontal openings, one commencing within 12 inches (300 mm) of the top ducts, one commencing

Summary of the content on the page No. 14

InstallInG the new water heater cheMIcal vapor corrosIon CORROSION OF THE FLUEWAYS AND vENT SYSTEM MAY OCCUR IF AIR FOR COMBUSTION CONTAINS CERTAIN CHEMICAL vAPORS. SUCH CORROSION MAY RESULT IN FAILURE AND RISK OF ASPHYXIATION. Spray can propellants, cleaning solvents, refrigerator and air This water heater shall not be connected to any heating systems or conditioning refrigerants, swimming pool chemicals, calcium component(s) used with a non-potable water heating appliance. and sodium chl

Summary of the content on the page No. 15

pressure reducing or flow regulating control valve should be used in MIXInG v alves the line to the dishwashing machine and should be adjusted to deliver water pressure between these limits. Water temperature over 125°F (52°C) can cause severe burns instantly resulting in severe injury or death. HOT WATER OUTLET Children, the elderly and the 12” TO 15” physically or mentally disabled are at (30-38 cm) highest risk for scald injury. TEMPERED WATER OUTLET Feel water before bathing or showering.

Summary of the content on the page No. 16

fIGure 9. closed water sYsteMs fIGure 10. Water supply systems may, because of code requirements or such conditions as high line pressure, among others, have installed note: t o protect against untimely corrosion of hot and cold devices such as pressure reducing valves, check valves, and back water fittings, it is strongly recommended that di-electric unions flow preventers. Devices such as these cause the water system to or couplings be installed on this water heater when connected be a

Summary of the content on the page No. 17

Fit pipe insulation over the incoming cold water line and the hot No valve or other obstruction is to be placed between the Temperature-Pressure Relief Valve and the tank. Do not connect water line. Make sure that the insulation is against the top cover of discharge piping directly to the drain unless a 6” (15.2 cm) air gap is the heater.Fit T & P valve insulation over valve. Make sure that the provided. To prevent bodily injury, hazard to life, or property damage, insulation does not inte

Summary of the content on the page No. 18

Consideration must be given to avoid freezing of the condensate Gas pIpInG lines which could result in excessive build up of condensate inside the water heater. Waterproof heat tape may be required to prevent freezing of the condensate lines. Please ensure that the outlet of the condensate drain does not create a slippery condition which could lead to personal injury. Make sure gas supplied is same type listed on model rating plate. The inlet gas pressure must not exceed 14 inch water col

Summary of the content on the page No. 19

hIGh altItude InstallatIons sedIMent traps A sediment trap shall be installed as close to the gas inlet of the water heater as practical at the time of water heater installation. The sediment trap shall be either a tee fitting with a capped nipple in the bottom outlet or other device recognized as an effective sediment trap. This high efficiency water heater is certified for use without Contaminants in the gas lines may cause improper operation of modification for an altitude of 10,000 fe

Summary of the content on the page No. 20

planned location of the vent terminal. ventInG 1. Layout total vent system to use a minimum of vent pipe and elbows. 2. This water heater is capable of venting flue gases equivalent to 45’ (13.7 m) of 2” pipe, 128’ (39 m) of 3” pipe as listed in Table 2. t able 2 number of 2” Maximum 3” Maximum 90° elbows pipe - ft. (m) pipe - ft. (m) 1 40 (12.19) 120 (36.57) 2 35 (10.66) 115 (35.05) 3 30 (9.14) 110 (33.52) 4 25 (7.62) 105 (32) 5 20 (6.09) 100 (30.48) 6 15 (4.57) 95 (28.95) The minimum vent l


Alternative user manuals
# User manual Category Download
1 A.O. Smith 000 User manual Water Heater 8
2 A.O. Smith 101 User manual Water Heater 3
3 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
4 A.O. Smith 104 Series User manual Water Heater 3
5 A.O. Smith 104 - 110 User manual Water Heater 6
6 A.O. Smith 105 Series User manual Water Heater 1
7 A.O. Smith 15 User manual Water Heater 0
8 A.O. Smith 2100 User manual Water Heater 0
9 A.O. Smith 1850 User manual Water Heater 0
10 A.O. Smith 185874-001 User manual Water Heater 0
11 A.O. Smith 185762-000 User manual Water Heater 0
12 A.O. Smith 2500 User manual Water Heater 1
13 A.O. Smith 184769-000 User manual Water Heater 1
14 A.O. Smith 1300 User manual Water Heater 0
15 A.O. Smith 197835-001 User manual Water Heater 0
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6