Bradford-White Corp IGI-1804-10(N.X) user manual

User manual for the device Bradford-White Corp IGI-1804-10(N.X)

Device: Bradford-White Corp IGI-1804-10(N.X)
Category: Water Heater
Manufacturer: Bradford-White Corp
Size: 3.47 MB
Added : 6/6/2014
Number of pages: 64
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bradford-White Corp IGI-1804-10(N.X). Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bradford-White Corp IGI-1804-10(N.X).

For your convenience

If looking through the Bradford-White Corp IGI-1804-10(N.X) user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bradford-White Corp IGI-1804-10(N.X) on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bradford-White Corp IGI-1804-10(N.X) to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bradford-White Corp IGI-1804-10(N.X) User manual - Online PDF
Advertisement
« Page 1 of 64 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bradford-White Corp IGI-1804-10(N.X) but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bradford-White Corp IGI-1804-10(N.X). If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1

Tankless Gas Water Heater
SERVICE
MANUAL
Troubleshooting Guide
and Instruction for Service
(To be performed ONLY by qualified service providers)
®
For the Bradford White EverHot
Interior Tankless
Gas Water Heater Models:
IGI-180R-10(N,X) IGI-180C-5(N,X)
Save this manual for future reference
Manual 45095A
1

Summary of the content on the page No. 2

Key to Warning Symbols Failure to comply with the following instructions may results in serious personal injury or damage to the appliance. Be careful of possible electric shock. Wiring inside this appliance may potentially be at 120 volts. Disconnect power supply to unit when carrying out the following service repairs. Read Fault Diagnosis and Wiring Diagram carefully to avoid incorrect wiring. Do not disassemble. Parts within can not be exchanged or diagnosed faulty. Please follow the instruct

Summary of the content on the page No. 3

TABLE OF CONTENTS Section Description Page - - - Glossary of Terms and Symbols. . . . . . . . . . . . . . . . . . . . . . . . . . . .4 I. . . . . . . . . . . .General Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 a. How to Use This Manual. . . . . . . . . . . . . . . . . . . . . . . . . .6 b. Cut Away illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 c. Schematic illustration. . . . . . . . . . . . . . . . . . . . . . . . . . . .8 II.

Summary of the content on the page No. 4

GLOSSARY OF TERMS AND SYMBOLS This glossary of terms and symbols is provided to assist you in understanding some of the language used throughout this manual. dB(A) - sound pressure level in decibels, “A” range DC - direct current AC - alternating current WFCD - water flow control device FB - feedback information Hz - hertz IC - integrated circuit BTU/H - British thermal units per hour PSI - Pounds per square inch LED - light emitting diode GPM - gallons per minute mA - milliamps W.C. - inches of

Summary of the content on the page No. 5

I - GENERAL INFORMATION This tankless water heater is a high output, high efficiency appliance, which heats the water continuously as hot water is being drawn for use. Unlike tank type storage water heaters, this water heater does not store hot water. The burner operates whenever there is a demand for hot water and is off when the hot water flow stops. Hot water is continuously supplied for any length of time required as long as the specified flow rates are not exceeded. There is no need to

Summary of the content on the page No. 6

I - GENERAL INFORMATION (cont.) HOW TO USE THIS MANUAL It is intended for this manual to be used by qualified service personnel for the primary purpose of troubleshooting analysis and repair of this tankless gas fired water heater. Understanding the basic operation of the "Main Components" and the "Sequence of Operation" sections of this manual will contribute greatly to your success in the troubleshooting analysis of this product. Sections of this manual reference general information and speci

Summary of the content on the page No. 7

I - GENERAL INFORMATION (cont.) CUT-AWAY ILLUSTRATION 7

Summary of the content on the page No. 8

I - GENERAL INFORMATION (cont.) SCHEMATIC ILLUSTRATION 8

Summary of the content on the page No. 9

II - SPECIFICATIONS - GENERAL Model type RESIDENTIAL COMMERCIAL Type of appliance Temperature controlled continuous flow gas hot water system Operation With / without remote controls, mounted in kitchen, bathroom, etc. Exhaust system Direct Vent - Forced combustion Maximum/Minimum gas rate 180,000 BTU's - 15,000 BTU's Natural Gas (Input BTU's) 180,000 BTU's - 15,000 BTU's Propane Gas Hot water capacity, 0.5 to 6.5 GPM (50°F rise) Setpoint Temperature Factory setting - 120°F Factory setting - 140

Summary of the content on the page No. 10

II - SPECIFICATIONS - GENERAL Safety devices Appliance - AC 120 Volts - 60Hz. 15A - Dedicated Remote control DC 12 Volts (Digital) Flame failure - Flame rod Boiling protection - 203°F Remaining flame (OHS) 194°F bi-metal switch Thermal fuse 264°F Automatic frost protection - Bimetal sensor & anti-frost heaters Combustion fan rpm check - Integrated circuit Over current - Glass fuse (3 amp) If remote fails or becomes disconnected unit defaults to 100°F with water flowing, this is an anti-scald fe

Summary of the content on the page No. 11

II - SPECIFICATIONS - COMBUSTION Item Gas type Natural Propane Gas consumption Minimum Btu’s 15,000 15,000 Maximum Btu’s 180,000 180,000 Injector Diameter Upper Ø.037 (.95mm) Ø.029 (.75mm) Inches (mm) Lower Ø.062 (1.6mm) Ø.045 (1.15mm) Main Burner B3A7-1(Lean and Rich Bunsen Burner) Main Damper H73-115, Upper: Ø6, Lower: (Not used) Gas Pressure Minimum supply 6" W.C. 10" W.C. Supply/Manifold Maximum supply 10.5" W.C. 13.5" W.C. Low Fire manifold 0.77” W.C 0.93” W.C High Fire manifold 3.7” W.

Summary of the content on the page No. 12

II - SPECIFICATIONS (cont.) DIP SWITCH SETTINGS DANGER Do not attempt to adjust dip switch settings from there factory default settings. Doing so will result in damage to unit, property damage, personal injury or death. Contact Technical Support for information pertaining to dip switch function. FACTORY DEFAULT SETTING, RESIDENTIAL UNITS Natural Gas Propane Gas Dip Switch Settings: Dip Switch Settings: (SW1) (SW2) (SW1) (SW2) #1 = Off #1 = On #1 = Off #1 = Off #2 = On #2 = Off #2 = On #2 = Off #

Summary of the content on the page No. 13

II - SPECIFICATIONS (cont.) DIP SWITCH SETTINGS Combustion Blower Dip Switch Settings for Vent Length Compensation Under 22 Feet (6.7 m): To assure optimum efficiency and reduced noise levels, the combustion blower switch has two dip switch settings. Dip switch number 1 (top dip switch) is shipped from the factory set to the OFF position to compensate for the maximum vent/air intake length. Depending upon the vent/air intake length of the installation, Dip Switch Number 1 may need to be adjuste

Summary of the content on the page No. 14

II - SPECIFICATIONS (cont.) VENTING TABLE Venting Table – Examples of Maximum Venting Distances with Various Elbow Combinations Maximum Straight Number of Number of Maximum Total Pipe Distance 90 degree elbows 45 degree elbows Equivalent Feet (meters) of Vent Pipe 35 Ft. (10.7 m) 1 41 (12.5 m) 29 Ft. (8.8 m) 2 41 (12.5 m) 23 Ft. (7.0 m) 3 41 (12.5 m) 17 Ft. (5.2 m) 4 41 (12.5 m) 33.5 Ft. (10.2 m) 1 1 41 (12.5 m) 32 Ft. (9.8 m) 1 2 41 (12.5 m) 27.5 Ft. (8.4 m) 2 1 41 (12.5 m) NOTICE Each 90 degre

Summary of the content on the page No. 15

III - MAIN COMPONENTS 1. Mechanical Water Regulator The unique water regulator mechanism ensures the hot water is maintained with no noticeable change to the desired temperature during use, even if water pressure drops due to another tap being turned on and increasing the demand. 2. Preset Bypass A preset volume of cold water is mixed with water heated in the heat exchanger. 3. Burner The burner assembly is made up of 16 identical stainless steel Bunsen burners, secured by an aluminized steel fr

Summary of the content on the page No. 16

III - MAIN COMPONENTS (cont.) 5. Combustion Fan Air for the combustion is supplied by a centrifugal fan driven by a DC motor. After a pre-purge period of 0.2 seconds, the fan speed is controlled by the PCB to provide the correct volume of air for combustion. The calculation for the fan speed is based upon incoming water temperature, water flow and the temperature selected on the remote controls. The actual speed of the motor is continuously monitored by a magnetic pulse sensor. This sensor emits

Summary of the content on the page No. 17

IV - SAFETY DEVICE FUNCTION Flame Failure Situated to the right of the burner in the front of the combustion chamber, the flame rod monitors the combustion process. This sensor monitors the flame intensity, while the PCB compares this signal to the feed back signal from the combustion fan motor, water flow control, and gas flow through the POV valve. If any one of the feedback signals are incorrect, the unit will shut off, preventing discharge of gas to the burner. Over Heat Protection Device Al

Summary of the content on the page No. 18

IV - SAFETY DEVICE FUNCTION (cont.) Over temperature Cut-Off The temperature of the outgoing hot water is constantly monitored by the water temperature thermistor located near the outlet of the appliance. If the outgoing water temperature reaches 5 °F above the preset temperature, the burner will automatically deactivate. The burner will ignite again when the outgoing hot water temperature falls below the preset temperature. 18

Summary of the content on the page No. 19

V - SEQUENCE OF OPERATION The preset temperature is selected at one of the remotes controls (where fitted). Where no remote control is fitted , the default temperature can be set at 108, 120, 130, 140, 150, 160, 170, or 180°F. To select one of the above temperatures as your default setting, you MUST obtain written permission and training (Contact your technical service group). When the unit is first plugged into 120 volts, the PCB assumes an incoming water temperature of 77°F. This prevents the

Summary of the content on the page No. 20

V - SEQUENCE OF OPERATION (cont.) When the hot water tap is turned off, the water flow sensor stops revolving, and the magnetic pulse ceases, indicating to the PCB that there is no water flowing, in turn the PCB closes the gas valves. The combustion fan continues to operate for 65 seconds. This will provide quicker ignition when the tap is turned on and off in rapid succession, and removes the need for a pre-purge cycle allowing the burner to re-light immediately when a hot water tap is opened a


Alternative user manuals
# User manual Category Download
1 Bradford-White Corp -13 User manual Water Heater 30
2 Bradford-White Corp -12 User manual Water Heater 14
3 Bradford-White Corp -15 User manual Water Heater 15
4 Bradford-White Corp 203-B User manual Water Heater 9
5 Bradford-White Corp 103-B User manual Water Heater 7
6 Bradford-White Corp 105-B User manual Water Heater 1
7 Bradford-White Corp 216-B User manual Water Heater 1
8 Bradford-White Corp 238-37281-00R User manual Water Heater 3
9 Bradford-White Corp 238-16152-00F User manual Water Heater 1
10 Bradford-White Corp 238-44422-00G User manual Water Heater 2
11 Bradford-White Corp 238-44219-00J User manual Water Heater 0
12 Bradford-White Corp 238-47808-00A User manual Water Heater 0
13 Bradford-White Corp 355-B User manual Water Heater 0
14 Bradford-White Corp 25X-78B-3N User manual Water Heater 0
15 Bradford-White Corp 44219J User manual Water Heater 1
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6