Bradford-White Corp IGI-180R user manual

User manual for the device Bradford-White Corp IGI-180R

Device: Bradford-White Corp IGI-180R
Category: Water Heater
Manufacturer: Bradford-White Corp
Size: 2.04 MB
Added : 3/15/2014
Number of pages: 60
Print the manual

Download

How to use this site?

Our goal is to provide you with a quick access to the content of the user manual for Bradford-White Corp IGI-180R. Using the online preview, you can quickly view the contents and go to the page where you will find the solution to your problem with Bradford-White Corp IGI-180R.

For your convenience

If looking through the Bradford-White Corp IGI-180R user manual directly on this website is not convenient for you, there are two possible solutions:

  • Full Screen Viewing - to easily view the user manual (without downloading it to your computer), you can use full-screen viewing mode. To start viewing the user manual Bradford-White Corp IGI-180R on full screen, use the button Fullscreen.
  • Downloading to your computer - You can also download the user manual Bradford-White Corp IGI-180R to your computer and keep it in your files. However, if you do not want to take up too much of your disk space, you can always download it in the future from ManualsBase.
Bradford-White Corp IGI-180R User manual - Online PDF
Advertisement
« Page 1 of 60 »
Advertisement
Print version

Many people prefer to read the documents not on the screen, but in the printed version. The option to print the manual has also been provided, and you can use it by clicking the link above - Print the manual. You do not have to print the entire manual Bradford-White Corp IGI-180R but the selected pages only. paper.

Summaries

Below you will find previews of the content of the user manuals presented on the following pages to Bradford-White Corp IGI-180R. If you want to quickly view the content of pages found on the following pages of the manual, you can use them.

Abstracts of contents
Summary of the content on the page No. 1




BRADFORD WHITE EVERHOT® TANKLESS GAS WATER HEATER
FOR INTERIOR INSTALLATION
IGI-180R AND IGI-180C MODEL SERIES



WARNING: If the information in

these instructions is not followed

exactly, a fire or explosion may

result causing property damage,

personal injury or death


Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not to

Summary of the content on the page No. 2

SECTION I: IMPORTANT INFORMATION READ CAREFULLY This gas-fired water heater is design certified by CSA International under the American National Standard, Z21.10.3 (as indicated on the rating plate) and CAN/CGA 4.3-M (as indicated on the rating plate) available from CSA Standards Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3. This water heater must be installed in accordance with local codes. In the absence of local codes, it must be installed i

Summary of the content on the page No. 3

DANGER DO NOT store or use gasoline or other flammable, combustible, or corrosive vapors and/or liquids in the vicinity of this or any other appliance. Failure to properly install the vent and air intake (if applicable) system could result in property damage, personal injury, or death. DO NOT install any damaged venting system components. If damage is evident then please contact the supplier where the water heater

Summary of the content on the page No. 4

WARNING DO NOT tamper with or alter the water heater and/or controls. DO NOT operate water heater with jumpered or absent controls or safety devices. DO NOT operate water heater if any external part has been under water. Immediately call a qualified service agency to inspect the appliance and to replace any part of the control system including gas controls, which has been under water. DO NOT attempt to use this water

Summary of the content on the page No. 5

WARNING Liquefied petroleum gases/propane gas is heavier than air and will remain at floor level if there is a leak. Basements, crawl spaces, closets and areas below ground level will serve as pockets for accumulation of leaking gas. Before lighting, smell all around the appliance area for gas. Be sure to smell next to the floor. IF YOU SMELL GAS: • DO NOT try to light any appliance. • DO NOT touch any electric switc

Summary of the content on the page No. 6

SECTION II: SPECIFICATIONS Max. Flow Rate @ Degree Temperature Rise Max. Min. Temp Input Input Rise Model No. Rating Rating 40°F 60°F 80°F 100°F 120°F 140°F Btu/hr. Btu/hr. IGI-180R-10N 180,000 15,000 Flow IGI-180R-10X Rate 7.7 5.1 3.8 3.1 2.6 2.2 IGI-180C-5N Gal/Min. IGI-180C-5X First Hour 462 306 228 186 156 132 Supply Gal/Hr. Max. Flow Rate @ Degree Temperature Rise Max. Min. Temp Input Input Rise Model No. Rating Rating 22

Summary of the content on the page No. 7

EVERHOT® IGI Model Series Dimensions 7

Summary of the content on the page No. 8

SPECIFICATIONS Dimensions (Inches) Height: Width: Depth: Outside Vent Venting Connection: Height: 25 5/8” 13 25/32” 8 13/16” 2 21/32” (65.1 cm) (35 cm) (22.4 cm) 5” dia. (6.7 cm) (12.7 cm) Above top of cabinet Clearances from Top of water heater: 6” (15.2 cm), Front: 6” (15.2 cm), Sides: 2” (5.1 cm), Combustible Materials: Back: 0”, Floor: 12” (30.5 cm), Vent/Air Intake Connectors: 0” Maximum/Minimum Gas 180,000 maximum / 15,000 minimum for both Natural and L.P. Gases. Inpu

Summary of the content on the page No. 9

SECTION III: GENERAL INFORMATION FEATURES The Bradford White EVERHOT® IGI series tankless water heater is a high output, high efficiency appliance, which heats the water continuously as hot water is being drawn for use. Unlike tank type storage water heaters, this water heater does not store hot water. The burner operates whenever there is a demand for hot water and is off when the hot water flow stops. Hot water is continuously supplied for any length of time required, as long as

Summary of the content on the page No. 10

SECTION IV: INSTALLATION INSTRUCTIONS WARNING INSTALLATION OF THIS WATER HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF A LICENSED PLUMBER. PLUMBING, AIR SUPPLY, VENTING, GAS SUPPLY AND ELECTRICAL WORK ARE REQUIRED. DO NOT ATTEMPT TO LIGHT ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOLLOWING: • Liquefied petroleum gases/propane gas and natural gas have an odorant added by the gas supplier that aids in detection of the gas. • Most people recognize this od

Summary of the content on the page No. 11

WARNI NG • This water heater is suitable for potable water heating only. DO NOT use this water heater for space heating or combination space heating/domestic WARNING water heating. • This water heater is not suitable for use in pool or spa applications. • The water heater must be installed indoors using the proper venting system components for combustion air supply and discharging flue products to the outdoors. Contact the supplier of this water heater or Brad

Summary of the content on the page No. 12

Connectors of this water heater. However, it is recommended that at least 12” (30.5 cm) from the top and 24” (61 cm) from the front be provided for servicing. 4. If the water heater is installed in a confined space, such as a closet, ventilation air must be provided to prevent increased room temperature. Excessive ambient temperatures surrounding the water heater may shorten the life of the controls. REMOVE CARTON Move water heater to a location near where it will be installed. Care

Summary of the content on the page No. 13

SECTION V: WATER CONNECTIONS WARNING Failure to install and maintain a new, listed pressure relief valve will release the manufacturer from any claim, which might result from excessive temperature and pressures. Keep clear of the pressure relief valve discharge line outlet. The discharge may be hot enough to cause scald injury. The water is under pressure and may splash. WARNING DO NOT reverse the inlet and outlet (cold and hot water) connections on the water heater. This may

Summary of the content on the page No. 14

plumbing system to the house. All soldering materials and piping must be compatible with potable water. Unions should be installed on both the hot and cold water lines for future servicing and disconnection of the water heater. Install a shut-off valve in the cold water supply line. 2. In order to service the water heater in the event the heat exchanger needs to be flushed of lime deposits, tee fittings with shut off valves and service connections to hoses should be installed. Also

Summary of the content on the page No. 15

Recommended Piping for a Basic Installation (Fig. 1) 15

Summary of the content on the page No. 16

Recommended Piping for a Circulation System (Fig. 2) 16

Summary of the content on the page No. 17

Recommended Piping for Power Failure Freeze Protection As long as electrical power and gas are supplied to the EVERHOT® water heater, freeze protection is provided to the heat exchanger and piping inside the water heater with ambient temperatures as cold as -30°F (-34°C), when protected from direct wind exposure. In the event of a power failure with ambient temperatures below freezing, the water heater must be drained of all water to prevent freeze damage. The water heater may be drai

Summary of the content on the page No. 18

Recommended Piping for Back-up Storage System For hotels, motels, and other high flow applications (Fig. 4) Note: The Primary Circulator for the water heating loop must be sized for 21 GPM @ 35 Ft. Head 18

Summary of the content on the page No. 19

PRESSURE RELIEF VALVE – WARNING Keep clear of the pressure relief valve discharge line outlet. The discharge may be hot enough to cause scald injury. The water is under pressure and may splash. For protection against excessive pressure, install pressure protective equipment required by local codes, but not less than a pressure relief valve certified by a nationally recognized testing laboratory that maintains per

Summary of the content on the page No. 20

SECTION VI: VENTING WARNING The venting system must be properly installed. Failure to properly install the vent system could result in property damage, personal injury, or death. DO NOT install damaged venting system components. If damage is evident then please contact the supplier where the water heater was purchased or the manufacturer listed on the rating plate for replacement parts. Use only the vent terminals and vent/air intake components available for venting this water heate


Alternative user manuals
# User manual Category Download
1 Bradford-White Corp -13 User manual Water Heater 30
2 Bradford-White Corp -12 User manual Water Heater 14
3 Bradford-White Corp -15 User manual Water Heater 15
4 Bradford-White Corp 203-B User manual Water Heater 9
5 Bradford-White Corp 103-B User manual Water Heater 7
6 Bradford-White Corp 105-B User manual Water Heater 1
7 Bradford-White Corp 216-B User manual Water Heater 1
8 Bradford-White Corp 238-37281-00R User manual Water Heater 3
9 Bradford-White Corp 238-16152-00F User manual Water Heater 1
10 Bradford-White Corp 238-44422-00G User manual Water Heater 2
11 Bradford-White Corp 238-44219-00J User manual Water Heater 0
12 Bradford-White Corp 238-47808-00A User manual Water Heater 0
13 Bradford-White Corp 355-B User manual Water Heater 0
14 Bradford-White Corp 25X-78B-3N User manual Water Heater 0
15 Bradford-White Corp 44219J User manual Water Heater 1
16 A.O. Smith 000 User manual Water Heater 8
17 A.O. Smith 101 User manual Water Heater 3
18 A.O. Smith 12 40GPC T 100 User manual Water Heater 4
19 A.O. Smith 104 Series User manual Water Heater 3
20 A.O. Smith 104 - 110 User manual Water Heater 6